Plan Review Details - Permit 17090486
| Plan Review Stops For Permit 17090486 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-10-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-24 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-24 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2017-11-16 13:09:08 | SHEETS 1 AND 3 ARE SHOWN FOR REFERENCE ONLY. THE SCOPE | | | OF WORK FOR THIS PLAN IS STATED ON SHEET 2 AND INCLUDES | | | ONLY THE WORK ON THE SECOND FLOOR, SUITE 200. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-10-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-05 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-05 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2017-10-05 14:00:08 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN IS REQUIRED | | | TO BEAR THE NAME AND BE SIGNED AND SEALED BY THE PERSON | | | RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. FBC | | | 107.2.1, FS 471, 481 | | | 2. SCOPE OF WORK STATES THIS WORK IS FOR GROUND FLOOR | | | ONLY, BUT THERE ARE 3 FLOORS OF WORK SHOWN. CLARIFY | | | AND/OR CORRECT. INDICATE WHICH DEVICES ARE EXISTING AND | | | WHICH ARE NEW. FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-09-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-09-25 |
Time |
15:20 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-10-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-24 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-20 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2017-10-23 11:18:20 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-10-23 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-10-23 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-09-22 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2017-09-25 13:20:23 | ROUTED TO FIRE INBOX |
|
|
|