| Plan Review Stops For Permit 17090467 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2018-02-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-02-05 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-02-05 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
|
Date |
2018-01-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-30 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-30 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2018-01-30 11:03:46 | 01/30/18 | | | RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL | | | FROM QUICKCALCS. | | | (ENERGY CALCULATIONS AND EQUIPMENT SIZING | | | CALCULATIONS). JG. | | | | | | | | | | | | ENERGY CALCULATIONS REVISION COURTESY REVIEW; | | | 1- OWNER OR LEGAL AGENT TO SIGN AND DATE ENERGY | | | CALCULATIONS. | | | 3- BUILDER TO COMPLETE THE EPL CARD. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-29 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-29 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2018-01-29 13:36:51 | 01/29/18 | | | RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL | | | FROM QUICKCALCS. | | | (ENERGY CALCULATIONS AND EQUIPMENT SIZING | | | CALCULATIONS). JG. | | | | | | | | | ENERGY CALCULATIONS REVISION COURTESY REVIEW; | | | 1- THE PERMIT OFFICE IS CITY OF WEST PALM BEACH NOT | | | CITY OF PALM BEACH. (PALM BEACH IS ANOTHER | | | MUNICIPALITY) | | | 2- OWNER OR LEGAL AGENT TO SIGN AND DATE ENERGY | | | CALCULATIONS. | | | 3- BUILDER TO COMPLETE THE EPL CARD. | | | | | | NEW COMMENT: | | | 1- NUMBER OF PEOPLE WAS CHANGED FROM 8 PEOPLE TO 12 | | | PEOPLE. 8 PEOPLE WAS A REASONABLE NUMBER OF PEOPLE FOR | | | A 6 BEDROOM HOUSE WITH 2 MASTER BEDROOMS. THAT'S WHY I | | | DIDN'T SAY ANYTHING ABOUT THE NUMBER OF PEOPLE | | | CONSIDERED ON THE ENERGY CALCULATIONS. REVISED ENERGY | | | CALCULATIONS ARE NOW SHOWING 4 PEOPLE IN THE GREAT | | | ROOM. THIS DOESN'T LOOK CORRECT SINCE THE NUMBER OF | | | PEOPLE ARE ALREADY COUNTED IN THE BEDROOMS. REVISE AS | | | REQUIRED. NOTE: NUMBER OF PEOPLE MAY AFFECT THE SIZING | | | OF THE A/C EQUIPMENT. MAY BE THAT'S WHY THE EQUIPMENT | | | SIZING CALCULATIONS ARE USING 12 PEOPLE INSTEAD OF 8. | | | THE ENERGY CODE DOESN'T ALLOW TO USE FACTORS THAT | | | AFFECT THE EQUIPMENT SIZING. SEE SEC. R403.6.1 | | | FBC-ENERGY CONSERVATION. REVISE AS REQUIRED USING THE | | | CORRECT NUMBER OF PEOPLE. EQUIPMENT SIZING CALCULATIONS | | | WILL NEED TO BE REVISED AS WELL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2018-01-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-26 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-26 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2018-01-26 14:40:47 | RECEIVED E-MAIL FROM NICOLE BLACKWELL FROM QUICKCALCS. | | | NEW ENERGY CALCULATIONS AND EQUIPMENT SIZING | | | CALCULATIONS. JG. | | | | | | | | | ENERGY CALCULATIONS COURTESY REVIEW; | | | 1- CORRECT ADDRESS IS 5401 S. OLIVE AVE NOT 541. | | | 2- NEED BUILDER'S NAME. | | | 3- THE PERMIT OFFICE IS CITY OF WEST PALM BEACH NOT | | | PALM BEACH COUNTY | | | 4- NEED THE NAME OF THE PERSON PREPARING THE ENERGY | | | CALCULATIONS AS REQUIRED BY SEC. R405.4.2 FBC ENERGY | | | CONSERVATION. | | | 5- ITEM #15 IS TAKING THE CEILING FAN CREDIT. PLANS | | | DON'T SHOW CEILING FANS. IF FANS ARE REQUIRED TO PASS | | | THE ENERGY CALCULATIONS, THEN ENGINEER OF RECORD NEEDS | | | TO REVISE PLAN SHOWING THE CEILING FAN LOCATION AND | | | SIZE AS REQUIRED BY TABLE R405.7.6 FBC ENERGY | | | CONSERVATION. NOTE: GREAT ROOM WILL NEED TO HAVE 2 | | | CEILING FANS. | | | 6- OWNER OR LEGAL AGENT TO SIGN AND DATE ENERGY | | | CALCULATIONS. | | | 7- SPACES INFORMATION ON PAGE 2 OF 7. CLARIFY WHY ITEM | | | #9 IS THE KITCHEN, BUT IN THE KITCHEN COLUMN IT SAYS | | | THAT THERE IS NOT KITCHEN? | | | 8- ATTIC VENTILATION ON PAGE 3 OF 7 SPECIFIES A VENT | | | RATIO OF 1/300. PLANS DON'T PROVIDE ANY INFORMATION | | | SHOWING THAT THE HOUSE WAS DESIGNED WITH A VENT RATIO | | | OF 1/300. TYPICALLY THE VENT RATIO IS 1/150. IF USING | | | THE 1/300 VENT RATIO, THEN ENGINEER OF RECORD NEEDS TO | | | REVISE PLANS. SEE THE EXCEPTION ON SEC. R806.2 FBC | | | RESIDENTIAL FOR REQUIREMENTS OF A 1/300 VENT RATIO. | | | 9- THE WALL AND WINDOW INFORMATION ON PAGE 5 OF 7 NEEDS | | | TO BE REVISED TO SHOW THE ACTUAL ORIENTATION OF THE | | | BUILDING. FOR EXAMPLE THE ENTRY DOORS ARE FACING EAST | | | NOT WEST. AND, THE COVERED PATIO SLIDING GLASS DOORS | | | ARE FACING WEST NOT EAST. REVISE AS REQUIRED. | | | 10- BUILDER TO COMPLETE THE EPL CARD. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2018-01-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-17 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-17 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2018-01-17 09:16:30 | RESIDENTIAL (R3) REVISION FOURTH BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | | | | NOTE: | | | REVISION FEES APPLY ON EVERY RE-SUBMITTAL. | | | | | | | | | ORIGINAL COMMENT: | | | 1- REVISE ENERGY CALCULATIONS SUBMITTED: | | | DOORS INFORMATION ON PAGE 3 OF 5 IS INCORRECT. THERE | | | ARE NOT INSULATED 16'-0" X 8'-0" DOORS ON THE EAST SIDE | | | OF THE HOUSE. SEE PLANS AND PRODUCT APPROVALS SUBMITTED | | | AND REVISE AS REQUIRED. NOTE: THIS ITEM WAS MENTIONED | | | ON PREVIOUS COMMENTS BUT HAVE NOT BEEN ADDRESSED. NOTE: | | | REVISION FEES APPLY ON EVERY RE-SUBMITTAL. | | | | | | RESPONSE: | | | ONLY THE PAGE 3 OF 5 WAS REVISED. THIS IS A COMPUTER | | | GENERATED PROGRAM. THEREFORE, ANY REVISION WILL AFFECT | | | THE OVERALL REPORT. NEED TO PROVIDE COMPLETE REVISED | | | REPORT. | | | IN ADDITION, THE ORIGINAL REPORT WAS DONE USING THE | | | 2014 PROGRAM WHICH WAS THE CODE IN EFFECT FOR THIS | | | PERMIT. REVISED PAGE 3 OF 5 IS DONE USING THE 2017 CODE | | | PROGRAM. MISMATCHING PROGRAMS IS NOT ALLOWED. NEED TO | | | PROVIDE COMPLETE REVISED REPORT USING THE CODE PROGRAM | | | IN EFFECT AT TIME OF PERMIT ISSUANCE (2014). | | | | | | | | | 2- OWES $206 FOR REVISION FEES. | | | OWES $154.50 FROM PREVIOUS REVISION SUBMITTAL. AND, | | | OWES $151.50 FOR CURRENT RE-SUBMITTAL. REVISED ENERGY | | | CALCULATIONS. | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-12-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-12-28 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-12-28 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2017-12-28 08:58:16 | RESIDENTIAL (R3) REVISION THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | NOTE: REVISION FEES APPLY ON EVERY RE-SUBMITTAL. | | | | | | | | | 1- REVISE ENERGY CALCULATIONS SUBMITTED: | | | DOORS INFORMATION ON PAGE 3 OF 5 IS INCORRECT. THERE | | | ARE NOT INSULATED 16'-0" X 8'-0" DOORS ON-THE EAST SIDE | | | OF THE HOUSE. SEE PLANS AND PRODUCT APPROVALS SUBMITTED | | | AND REVISE AS REQUIRED. NOTE: THIS ITEM WAS MENTIONED | | | ON PREVIOUS COMMENTS BUT HAVE NOT BEEN ADDRESSED. NOTE: | | | REVISION FEES APPLY ON EVERY RE-SUBMITTAL. | | | | | | | | | 2- OWES $154.50 FOR THIS REVISION RE-SUBMITTAL FEES. | | | NOTE: REVISION FEES APPLY ON EVERY RE-SUBMITTAL. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-11-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-11-15 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-11-14 |
Time |
18:48 |
Sent To |
|
|
| Notes |
| 2017-11-14 19:03:38 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- TRUSS PACKAGE: SUBMIT REVISED TRUSS PACKAGE TO | | | BUILDING INSPECTOR AT TIME OF FRAMING INSPECTIONS. | | | A) THERE ARE TWO DIFFERENT ENGINEER SEALS ON THE COVER | | | PAGE. JULIUS LEE AND JOAQUIN VELEZ. IT LOOKS LIME THE | | | TRUSS DESIGNER IS JOAQUIN VELEZ NOT JULIUS LEE. REVISE | | | AS REQUIRED. | | | B) REVISE THE LICENSE NUMBER OF THE STRUCTURAL ENGINEER | | | OF RECORD. | | | C) ENGINEER OF RECORD TO REVIEW/APPROVE TRUSS PACKAGE | | | IN WRITING. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-10-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-10-04 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-10-04 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2017-09-26 14:30:41 | RESIDENTIAL (R3) REVISION BUILDING REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | | | | 1- REVISE ENERGY CALCULATIONS: | | | A) CALCULATIONS NEED TO BE DONE ON THE CORRECT | | | ORIENTATION OF THE BUILDING. SEE SURVEY AND PLANS AND | | | REVISE WALLS AND WINDOWS INFORMATION AS REQUIRED. SEC. | | | R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | NOTE: CHECK OVERHANG DEPTH AND SEPARATION. MET | | | CONTRACTOR ON 10/10/17. | | | | | | B) WALL TYPES ARE INCORRECT. THERE ARE NO INTERIOR | | | STEEL PARTITIONS SEPARATING A/C SPACE FROM NON A/C | | | SPACE. PLANS SPECIFY WOOD FRAMED WALLS. SEE PLANS AND | | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | C) REVISE THE DOORS INFORMATION SHOWN ON PAGE 3 OF 5. | | | WHERE ARE THE 16'-0" X 8'-0" INSULATED DOORS?. SEE | | | PLANS AND PRODUCT APPROVALS SUBMITTED. NOTE: DOORS WITH | | | GLAZING NEED TO BE CONSIDERED IN THE WINDOWS AREA AS | | | REQUIRED BY SEC. R405.5.3.3 FBC-ENERGY CONSERVATION. | | | REVISE AS REQUIRED. | | | RESPONSE: REPEAT COMMENT. | | | | | | | | | 2- A/C EQUIPMENT SIZING CALCULATIONS SUBMITTED: PROVIDE | | | COMPLETE EQUIPMENT SIZING CALCULATIONS "BASED ON | | | BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE | | | BUILDING" AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | NOTE: IT LOOKS LIKE THE EQUIPMENT SIZING CALCULATIONS | | | WERE DONE BY THE SAME PERSON WHO DID THE ENERGY | | | CALCULATIONS. THE ENERGY CALCULATIONS NEED TO BE | | | REVISED. SEE COMMENTS ON ITEM #1 ABOVE AND REVISE A/C | | | EQUIPMENT SIZING CALCULATIONS AS REQUIRED. | | | | | | 3- TRUSS PACKAGE SUBMITTED: | | | A) REVISE DESIGN LOADS TO MATCH DESIGN CRITERIA | | | SPECIFIED BY THE ENGINEER OF RECORD ON SHEET 2.1. NOTE: | | | KEEP IN MIND THAT FINISH ROOF IS CONCRETE TILE. | | | SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | B) TRUSS LAYOUT AND ALL INDIVIDUAL TRUSS DRAWINGS NEED | | | TO BE SIGNED AND SEALED AND HAVE THE TRUSS ENGINEER | | | INFORMATION IN ALL DRAWINGS AS REQUIRED BY FAC | | | 61G15-31.003. | | | NOTE: TRUSS LAYOUT WAS NOT SUBMITTED AT THIS TIME. NEED | | | TO SUBMIT PROPERLY SIGNED AND SEALED TRUSS LAYOUT. | | | | | | C) REVISED TRUSS PACKAGE TO BE APPROVED IN WRITING BY | | | THE ENGINEER OF RECORD PRIOR TO SUBMITTAL TO THIS | | | OFFICE. SEC. 107.3.4.2 CITY AMENDMENTS. | | | | | | NOTE: | | | THE REVISION FEE OF $207.00 WAS NOT PAID. NEED TO PAY | | | FEE NOW BEFORE ANY ADDITIONAL REVIEW IS PERFORMED. | | | ADDITIONAL FEES WILL BE CHARGED ON EVERY RE-SUBMITTALS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2018-02-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-02-05 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-02-01 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2018-02-02 10:43:45 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-30 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-01-30 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2018-01-30 11:02:52 | 01/30/18 | | | RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL | | | FROM QUICKCALCS. | | | (ENERGY CALCULATIONS AND EQUIPMENT SIZING | | | CALCULATIONS). JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-29 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-29 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2018-01-29 14:09:37 | 01/29/18 | | | RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL | | | FROM QUICKCALCS. | | | (ENERGY CALCULATIONS AND EQUIPMENT SIZING | | | CALCULATIONS). JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-01-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-26 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-26 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2018-01-26 14:39:33 | RECEIVED E-MAIL FROM NICOLE BLACKWELL FROM QUICKCALCS. | | | NEW ENERGY CALCULATIONS AND LOAD CALCULATIONS. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-01-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-17 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-12 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2018-01-16 11:25:48 | RESUB OF REVISION ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-12-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-12-28 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-12-19 |
Time |
15:36 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-11-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-11-15 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-11-08 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2017-11-09 13:14:35 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-10-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-10-04 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-09-22 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2017-09-25 10:30:03 | REVISION ROUTED TO JGOMEZ |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2018-02-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-02-05 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-02-05 |
Time |
15:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2018-02-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-30 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-30 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2018-01-30 11:04:01 | 01/30/18 | | | RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL | | | FROM QUICKCALCS. | | | (ENERGY CALCULATIONS AND EQUIPMENT SIZING | | | CALCULATIONS). JG. | | | | | | 1- REVISE A/C PLAN TO REFLECT THE NEW EQUIPMENT. | | | NOTE: DON'T FORGET TO HAVE THE NAME AND SIGNATURE OF | | | THE A/C CONTRACTOR RESPONSIBLE FOR THE A/C DESIGN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-29 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-29 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2018-01-29 14:10:04 | 01/29/18 | | | RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL | | | FROM QUICKCALCS. | | | (ENERGY CALCULATIONS AND EQUIPMENT SIZING | | | CALCULATIONS). JG. | | | | | | | | | | | | EQUIPMENT SIZING CALCULATIONS REVISION COURTESY REVIEW: | | | 1- THE NUMBER OF PEOPLE SHOWN ON THE EQUIPMENT SIZING | | | CALCULATIONS DOESN'T MATCH THE NUMBER OF PEOPLE SHOWN | | | ON THE ENERGY CALCULATIONS. REVISE AS REQUIRED. | | | | | | NEW COMMENT: | | | 1- NUMBER OF PEOPLE SHOWN ON THE ENERGY CALCULATIONS | | | WAS CHANGED FROM 8 PEOPLE TO 12 PEOPLE. 8 PEOPLE WAS A | | | REASONABLE NUMBER OF PEOPLE FOR A 6 BEDROOM HOUSE WITH | | | 2 MASTER BEDROOMS. THAT'S WHY I DIDN'T SAY ANYTHING | | | ABOUT THE NUMBER OF PEOPLE CONSIDERED ON THE ENERGY | | | CALCULATIONS. REVISED ENERGY CALCULATIONS ARE NOW | | | SHOWING 4 PEOPLE IN THE GREAT ROOM. THIS DOESN'T LOOK | | | CORRECT SINCE THE NUMBER OF PEOPLE ARE ALREADY COUNTED | | | IN THE BEDROOMS. REVISE AS REQUIRED. NOTE: NUMBER OF | | | PEOPLE MAY AFFECT THE SIZING OF THE A/C EQUIPMENT. MAY | | | BE THAT'S WHY THE EQUIPMENT SIZING CALCULATIONS ARE | | | USING 12 PEOPLE INSTEAD OF 8. THE ENERGY CODE DOESN'T | | | ALLOW TO USE FACTORS THAT AFFECT THE EQUIPMENT SIZING. | | | SEE SEC. R403.6.1 FBC-ENERGY CONSERVATION. REVISE AS | | | REQUIRED USING THE CORRECT NUMBER OF PEOPLE. | | | | | | 2- REVISE A/C PLAN TO REFLECT THE NEW EQUIPMENT. | | | NOTE: DON'T FORGET TO HAVE THE NAME AND SIGNATURE OF | | | THE A/C CONTRACTOR RESPONSIBLE FOR THE A/C DESIGN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2018-01-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-26 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-26 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2018-01-26 17:13:12 | RECEIVED E-MAIL FROM NICOLE BLACKWELL FROM QUICKCALCS. | | | NEW ENERGY CALCULATIONS AND EQUIPMENT SIZING | | | CALCULATIONS. JG. | | | | | | | | | EQUIPMENT SIZING CALCULATIONS COURTESY REVIEW: | | | 1- CORRECT ADDRESS IS 5401 S. OLIVE AVE NOT 541 | | | 2- TYPICALLY, THE SAME PERSON DOING THE ENERGY | | | CALCULATIONS TRANSFER THE INFORMATION TO DO THE | | | EQUIPMENT SIZING CALCULATIONS. ENERGY CALCULATIONS NEED | | | TO BE CORRECTED TO THE ACTUAL ORIENTATION OF THE | | | BUILDING. THEREFORE, EQUIPMENT SIZING CALCULATIONS NEED | | | TO BE REVISED ALSO REFLECTING THE ACTUAL ORIENTATION OF | | | THE BUILDING. | | | 3- THE NUMBER OF PEOPLE SHOWN ON THE EQUIPMENT SIZING | | | CALCULATIONS DOESN'T MATCH THE NUMBER OF PEOPLE SHOWN | | | ON THE ENERGY CALCULATIONS. REVISE AS REQUIRED. | | | 4- REVISE A/C PLAN TO REFLECT THE NEW EQUIPMENT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2018-01-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-17 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-17 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2018-01-17 11:52:46 | RESIDENTIAL (R3) REVISION FOURTH MECHANICAL REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | NOTE: REVISION FEES APPLY ON EVERY RE-SUBMITTAL. | | | | | | | | | ORIGINAL COMMENT: | | | 1- A/C EQUIPMENT SIZING CALCULATIONS SUBMITTED: PROVIDE | | | COMPLETE EQUIPMENT SIZING CALCULATIONS "BASED ON | | | BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE | | | BUILDING" AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. ONLY THE | | | SUMMARY PAGES WERE SUBMITTED. NEED THE COMPLETE | | | EQUIPMENT SIZING CALCULATIONS WORKSHEETS. | | | | | | | | | RESPONSE: | | | SAME SUMMARY CALCULATIONS WERE RE-SUBMITTED AGAIN. NEED | | | TO PROVIDE COMPLETE WORKSHEETS TO VERIFY HOW THE | | | EQUIPMENT WAS SIZED. | | | THIS WAS REQUIRED FROM THE BEGINNING OF THE MECHANICAL | | | REVIEWS BECAUSE IT LOOKS LIKE THE ORIGINAL CALCULATIONS | | | WERE DONE BASED ON THE BUILDING ORIENTATION WORST CASE | | | SCENARIO. BY DOING THIS THE EQUIPMENT MAY BE | | | OVER-SIZED. SEC. R403.6.1 FBC-ENERGY CONSERVATION, 5TH | | | EDITION (2014) REQUIRES CALCULATIONS TO BE DONE ON THE | | | ACTUAL ORIENTATION OF THE BUILDING AND DOESN'T ALLOW | | | EQUIPMENT OVERSIZING. BASED ON THE CALCULATIONS | | | SUBMITTED, THE TOTAL COOLING LOAD IS 32924. SEC. | | | R403.6.1.1 ALLOWS NOT MORE THAN 1.15 TIMES EQUIPMENT | | | SIZING GREATER THAN THE CALCULATED LOAD. THEREFORE, THE | | | EQUIPMENT SIZE SHOULD BE 3 TON. NOT 3.5 TON AS SHOWN ON | | | LOAD CALCULATIONS SUBMITTED. THIS ISSUE WAS NOT | | | VERIFIED BEFORE, BECAUSE THE ORIGINAL REQUEST TO | | | PROVIDE COMPLETE REPORT WAS NEVER ADDRESSED. | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2017-12-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-12-28 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-12-28 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2017-12-27 15:45:42 | RESIDENTIAL (R3) REVISION THIRD MECHANICAL REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | NOTE: REVISION FEES APPLY ON EVERY RE-SUBMITTAL. | | | | | | | | | 1- A/C EQUIPMENT SIZING CALCULATIONS SUBMITTED: PROVIDE | | | COMPLETE EQUIPMENT SIZING CALCULATIONS "BASED ON | | | BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE | | | BUILDING" AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. ONLY THE | | | SUMMARY PAGES WERE SUBMITTED. NEED THE COMPLETE | | | EQUIPMENT SIZING CALCULATIONS WORKSHEETS. | | | | | | 2- REVISED A/C PLAN ON SHEET 8.1 NEEDS THE NAME AND | | | SIGNATURE OF THE A/C CONTRACTOR WHO SIGNED THE APPROVED | | | PLAN AS REQUIRED BY SEC. 107.2.1 CITY AMENDMENTS. NOTE: | | | APPROVED PLAN WAS SIGNED BY THE A/C CONTRACTOR MAX AIR | | | COOLING, LLC. | | | | | | 3- OWES $154.50 FOR REVISION RE-SUBMITTAL FEES. NOTE: | | | REVISION FEES APPLY ON EVERY RE-SUBMITTAL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-11-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-11-15 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-11-15 |
Time |
07:57 |
Sent To |
I |
|
| Notes |
| 2017-11-15 12:03:11 | RESIDENTIAL (R3) REVISION SECOND MECHANICAL REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | | | | 1- A/C EQUIPMENT SIZING CALCULATIONS SUBMITTED: PROVIDE | | | COMPLETE EQUIPMENT SIZING CALCULATIONS "BASED ON | | | BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE | | | BUILDING" AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | NOTE: IT LOOKS LIKE THE EQUIPMENT SIZING CALCULATIONS | | | WERE DONE BY THE SAME PERSON WHO DID THE ENERGY | | | CALCULATIONS. THE ENERGY CALCULATIONS NEED TO BE | | | REVISED. SEE BUILDING REVIEW COMMENTS ON ITEM #1 AND | | | REVISE A/C EQUIPMENT SIZING CALCULATIONS AS REQUIRED. | | | | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. SAME | | | CALCULATIONS DATED AUGUST 25TH 2017 WERE SUBMITTED. | | | AND, ONLY THE SUMMARY PAGES WERE SUBMITTED. NEED THE | | | COMPLETE EQUIPMENT SIZING CALCULATIONS. IN ADDITION, | | | THE ENERGY CALCULATIONS WERE REVISED ON 10/23/17 | | | SHOWING THE ACTUAL ORIENTATION OF THE BUILDING, BUT THE | | | EQUIPMENT SIZING CALCULATIONS WERE NOT REVISED. | | | PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS BASED ON | | | THE ACTUAL ORIENTATION OF THE BUILDING AS REQUIRED BY | | | SEC. R403.6.1 FBC-ENERGY CONSERVATION. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-10-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-10-04 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-10-04 |
Time |
18:58 |
Sent To |
|
|
| Notes |
| 2017-10-04 19:00:29 | RESIDENTIAL (R3) REVISION MECHANICAL REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | | | | 1- A/C EQUIPMENT SIZING CALCULATIONS SUBMITTED: PROVIDE | | | COMPLETE EQUIPMENT SIZING CALCULATIONS "BASED ON | | | BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE | | | BUILDING" AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | NOTE: IT LOOKS LIKE THE EQUIPMENT SIZING CALCULATIONS | | | WERE DONE BY THE SAME PERSON WHO DID THE ENERGY | | | CALCULATIONS. THE ENERGY CALCULATIONS NEED TO BE | | | REVISED. SEE BUILDING REVIEW COMMENTS ON ITEM #1 AND | | | REVISE A/C EQUIPMENT SIZING CALCULATIONS AS REQUIRED. | | | | | | | | | NOTE: | | | THE REVISION FEE OF $207.00 WAS NOT PAID. NEED TO PAY | | | FEE NOW BEFORE ANY ADDITIONAL REVIEW IS PERFORMED. | | | ADDITIONAL FEES WILL BE CHARGED ON EVERY RE-SUBMITTALS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|