Plan Review Details - Permit 17090467
Plan Review Stops For Permit 17090467
Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2018-02-05 Cont ID  
Sent By jgomez Date 2018-02-05 Time 15:55 Rev Time 0.00
Received By jgomez Date 2018-02-05 Time 15:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status   Date 2018-01-30 Cont ID  
Sent By jgomez Date 2018-01-30 Time 11:05 Rev Time 0.00
Received By jgomez Date 2018-01-30 Time 11:02 Sent To  
Notes
2018-01-30 11:03:4601/30/18
 RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL
 FROM QUICKCALCS.
 (ENERGY CALCULATIONS AND EQUIPMENT SIZING
 CALCULATIONS). JG.
  
  
  
 ENERGY CALCULATIONS REVISION COURTESY REVIEW;
 1- OWNER OR LEGAL AGENT TO SIGN AND DATE ENERGY
 CALCULATIONS.
 3- BUILDER TO COMPLETE THE EPL CARD.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2018-01-29 Cont ID  
Sent By jgomez Date 2018-01-29 Time 14:08 Rev Time 0.00
Received By jgomez Date 2018-01-29 Time 13:09 Sent To  
Notes
2018-01-29 13:36:5101/29/18
 RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL
 FROM QUICKCALCS.
 (ENERGY CALCULATIONS AND EQUIPMENT SIZING
 CALCULATIONS). JG.
  
  
 ENERGY CALCULATIONS REVISION COURTESY REVIEW;
 1- THE PERMIT OFFICE IS CITY OF WEST PALM BEACH NOT
 CITY OF PALM BEACH. (PALM BEACH IS ANOTHER
 MUNICIPALITY)
 2- OWNER OR LEGAL AGENT TO SIGN AND DATE ENERGY
 CALCULATIONS.
 3- BUILDER TO COMPLETE THE EPL CARD.
  
 NEW COMMENT:
 1- NUMBER OF PEOPLE WAS CHANGED FROM 8 PEOPLE TO 12
 PEOPLE. 8 PEOPLE WAS A REASONABLE NUMBER OF PEOPLE FOR
 A 6 BEDROOM HOUSE WITH 2 MASTER BEDROOMS. THAT'S WHY I
 DIDN'T SAY ANYTHING ABOUT THE NUMBER OF PEOPLE
 CONSIDERED ON THE ENERGY CALCULATIONS. REVISED ENERGY
 CALCULATIONS ARE NOW SHOWING 4 PEOPLE IN THE GREAT
 ROOM. THIS DOESN'T LOOK CORRECT SINCE THE NUMBER OF
 PEOPLE ARE ALREADY COUNTED IN THE BEDROOMS. REVISE AS
 REQUIRED. NOTE: NUMBER OF PEOPLE MAY AFFECT THE SIZING
 OF THE A/C EQUIPMENT. MAY BE THAT'S WHY THE EQUIPMENT
 SIZING CALCULATIONS ARE USING 12 PEOPLE INSTEAD OF 8.
 THE ENERGY CODE DOESN'T ALLOW TO USE FACTORS THAT
 AFFECT THE EQUIPMENT SIZING. SEE SEC. R403.6.1
 FBC-ENERGY CONSERVATION. REVISE AS REQUIRED USING THE
 CORRECT NUMBER OF PEOPLE. EQUIPMENT SIZING CALCULATIONS
 WILL NEED TO BE REVISED AS WELL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2018-01-26 Cont ID  
Sent By jgomez Date 2018-01-26 Time 15:46 Rev Time 0.00
Received By jgomez Date 2018-01-26 Time 14:40 Sent To  
Notes
2018-01-26 14:40:47RECEIVED E-MAIL FROM NICOLE BLACKWELL FROM QUICKCALCS.
 NEW ENERGY CALCULATIONS AND EQUIPMENT SIZING
 CALCULATIONS. JG.
  
  
 ENERGY CALCULATIONS COURTESY REVIEW;
 1- CORRECT ADDRESS IS 5401 S. OLIVE AVE NOT 541.
 2- NEED BUILDER'S NAME.
 3- THE PERMIT OFFICE IS CITY OF WEST PALM BEACH NOT
 PALM BEACH COUNTY
 4- NEED THE NAME OF THE PERSON PREPARING THE ENERGY
 CALCULATIONS AS REQUIRED BY SEC. R405.4.2 FBC ENERGY
 CONSERVATION.
 5- ITEM #15 IS TAKING THE CEILING FAN CREDIT. PLANS
 DON'T SHOW CEILING FANS. IF FANS ARE REQUIRED TO PASS
 THE ENERGY CALCULATIONS, THEN ENGINEER OF RECORD NEEDS
 TO REVISE PLAN SHOWING THE CEILING FAN LOCATION AND
 SIZE AS REQUIRED BY TABLE R405.7.6 FBC ENERGY
 CONSERVATION. NOTE: GREAT ROOM WILL NEED TO HAVE 2
 CEILING FANS.
 6- OWNER OR LEGAL AGENT TO SIGN AND DATE ENERGY
 CALCULATIONS.
 7- SPACES INFORMATION ON PAGE 2 OF 7. CLARIFY WHY ITEM
 #9 IS THE KITCHEN, BUT IN THE KITCHEN COLUMN IT SAYS
 THAT THERE IS NOT KITCHEN?
 8- ATTIC VENTILATION ON PAGE 3 OF 7 SPECIFIES A VENT
 RATIO OF 1/300. PLANS DON'T PROVIDE ANY INFORMATION
 SHOWING THAT THE HOUSE WAS DESIGNED WITH A VENT RATIO
 OF 1/300. TYPICALLY THE VENT RATIO IS 1/150. IF USING
 THE 1/300 VENT RATIO, THEN ENGINEER OF RECORD NEEDS TO
 REVISE PLANS. SEE THE EXCEPTION ON SEC. R806.2 FBC
 RESIDENTIAL FOR REQUIREMENTS OF A 1/300 VENT RATIO.
 9- THE WALL AND WINDOW INFORMATION ON PAGE 5 OF 7 NEEDS
 TO BE REVISED TO SHOW THE ACTUAL ORIENTATION OF THE
 BUILDING. FOR EXAMPLE THE ENTRY DOORS ARE FACING EAST
 NOT WEST. AND, THE COVERED PATIO SLIDING GLASS DOORS
 ARE FACING WEST NOT EAST. REVISE AS REQUIRED.
 10- BUILDER TO COMPLETE THE EPL CARD.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2018-01-17 Cont ID  
Sent By jgomez Date 2018-01-17 Time 11:32 Rev Time 0.00
Received By jgomez Date 2018-01-17 Time 09:10 Sent To  
Notes
2018-01-17 09:16:30RESIDENTIAL (R3) REVISION FOURTH BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
  
 NOTE:
 REVISION FEES APPLY ON EVERY RE-SUBMITTAL.
  
  
 ORIGINAL COMMENT:
 1- REVISE ENERGY CALCULATIONS SUBMITTED:
 DOORS INFORMATION ON PAGE 3 OF 5 IS INCORRECT. THERE
 ARE NOT INSULATED 16'-0" X 8'-0" DOORS ON THE EAST SIDE
 OF THE HOUSE. SEE PLANS AND PRODUCT APPROVALS SUBMITTED
 AND REVISE AS REQUIRED. NOTE: THIS ITEM WAS MENTIONED
 ON PREVIOUS COMMENTS BUT HAVE NOT BEEN ADDRESSED. NOTE:
 REVISION FEES APPLY ON EVERY RE-SUBMITTAL.
  
 RESPONSE:
 ONLY THE PAGE 3 OF 5 WAS REVISED. THIS IS A COMPUTER
 GENERATED PROGRAM. THEREFORE, ANY REVISION WILL AFFECT
 THE OVERALL REPORT. NEED TO PROVIDE COMPLETE REVISED
 REPORT.
 IN ADDITION, THE ORIGINAL REPORT WAS DONE USING THE
 2014 PROGRAM WHICH WAS THE CODE IN EFFECT FOR THIS
 PERMIT. REVISED PAGE 3 OF 5 IS DONE USING THE 2017 CODE
 PROGRAM. MISMATCHING PROGRAMS IS NOT ALLOWED. NEED TO
 PROVIDE COMPLETE REVISED REPORT USING THE CODE PROGRAM
 IN EFFECT AT TIME OF PERMIT ISSUANCE (2014).
  
  
 2- OWES $206 FOR REVISION FEES.
 OWES $154.50 FROM PREVIOUS REVISION SUBMITTAL. AND,
 OWES $151.50 FOR CURRENT RE-SUBMITTAL. REVISED ENERGY
 CALCULATIONS.
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2017-12-28 Cont ID  
Sent By jgomez Date 2017-12-28 Time 08:58 Rev Time 0.00
Received By jgomez Date 2017-12-28 Time 08:52 Sent To  
Notes
2017-12-28 08:58:16RESIDENTIAL (R3) REVISION THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE: REVISION FEES APPLY ON EVERY RE-SUBMITTAL.
  
  
 1- REVISE ENERGY CALCULATIONS SUBMITTED:
 DOORS INFORMATION ON PAGE 3 OF 5 IS INCORRECT. THERE
 ARE NOT INSULATED 16'-0" X 8'-0" DOORS ON-THE EAST SIDE
 OF THE HOUSE. SEE PLANS AND PRODUCT APPROVALS SUBMITTED
 AND REVISE AS REQUIRED. NOTE: THIS ITEM WAS MENTIONED
 ON PREVIOUS COMMENTS BUT HAVE NOT BEEN ADDRESSED. NOTE:
 REVISION FEES APPLY ON EVERY RE-SUBMITTAL.
  
  
 2- OWES $154.50 FOR THIS REVISION RE-SUBMITTAL FEES.
 NOTE: REVISION FEES APPLY ON EVERY RE-SUBMITTAL.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-11-15 Cont ID  
Sent By jgomez Date 2017-11-15 Time 13:38 Rev Time 0.00
Received By jgomez Date 2017-11-14 Time 18:48 Sent To  
Notes
2017-11-14 19:03:38BUILDING REVIEW APPROVED WITH PROVISO:
 1- TRUSS PACKAGE: SUBMIT REVISED TRUSS PACKAGE TO
 BUILDING INSPECTOR AT TIME OF FRAMING INSPECTIONS.
 A) THERE ARE TWO DIFFERENT ENGINEER SEALS ON THE COVER
 PAGE. JULIUS LEE AND JOAQUIN VELEZ. IT LOOKS LIME THE
 TRUSS DESIGNER IS JOAQUIN VELEZ NOT JULIUS LEE. REVISE
 AS REQUIRED.
 B) REVISE THE LICENSE NUMBER OF THE STRUCTURAL ENGINEER
 OF RECORD.
 C) ENGINEER OF RECORD TO REVIEW/APPROVE TRUSS PACKAGE
 IN WRITING.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-10-04 Cont ID  
Sent By jgomez Date 2017-10-04 Time 18:58 Rev Time 0.00
Received By jgomez Date 2017-10-04 Time 15:11 Sent To  
Notes
2017-09-26 14:30:41RESIDENTIAL (R3) REVISION BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
  
 1- REVISE ENERGY CALCULATIONS:
 A) CALCULATIONS NEED TO BE DONE ON THE CORRECT
 ORIENTATION OF THE BUILDING. SEE SURVEY AND PLANS AND
 REVISE WALLS AND WINDOWS INFORMATION AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
 NOTE: CHECK OVERHANG DEPTH AND SEPARATION. MET
 CONTRACTOR ON 10/10/17.
  
 B) WALL TYPES ARE INCORRECT. THERE ARE NO INTERIOR
 STEEL PARTITIONS SEPARATING A/C SPACE FROM NON A/C
 SPACE. PLANS SPECIFY WOOD FRAMED WALLS. SEE PLANS AND
 REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 C) REVISE THE DOORS INFORMATION SHOWN ON PAGE 3 OF 5.
 WHERE ARE THE 16'-0" X 8'-0" INSULATED DOORS?. SEE
 PLANS AND PRODUCT APPROVALS SUBMITTED. NOTE: DOORS WITH
 GLAZING NEED TO BE CONSIDERED IN THE WINDOWS AREA AS
 REQUIRED BY SEC. R405.5.3.3 FBC-ENERGY CONSERVATION.
 REVISE AS REQUIRED.
 RESPONSE: REPEAT COMMENT.
  
  
 2- A/C EQUIPMENT SIZING CALCULATIONS SUBMITTED: PROVIDE
 COMPLETE EQUIPMENT SIZING CALCULATIONS "BASED ON
 BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE
 BUILDING" AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 NOTE: IT LOOKS LIKE THE EQUIPMENT SIZING CALCULATIONS
 WERE DONE BY THE SAME PERSON WHO DID THE ENERGY
 CALCULATIONS. THE ENERGY CALCULATIONS NEED TO BE
 REVISED. SEE COMMENTS ON ITEM #1 ABOVE AND REVISE A/C
 EQUIPMENT SIZING CALCULATIONS AS REQUIRED.
  
 3- TRUSS PACKAGE SUBMITTED:
 A) REVISE DESIGN LOADS TO MATCH DESIGN CRITERIA
 SPECIFIED BY THE ENGINEER OF RECORD ON SHEET 2.1. NOTE:
 KEEP IN MIND THAT FINISH ROOF IS CONCRETE TILE.
 SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 B) TRUSS LAYOUT AND ALL INDIVIDUAL TRUSS DRAWINGS NEED
 TO BE SIGNED AND SEALED AND HAVE THE TRUSS ENGINEER
 INFORMATION IN ALL DRAWINGS AS REQUIRED BY FAC
 61G15-31.003.
 NOTE: TRUSS LAYOUT WAS NOT SUBMITTED AT THIS TIME. NEED
 TO SUBMIT PROPERLY SIGNED AND SEALED TRUSS LAYOUT.
  
 C) REVISED TRUSS PACKAGE TO BE APPROVED IN WRITING BY
 THE ENGINEER OF RECORD PRIOR TO SUBMITTAL TO THIS
 OFFICE. SEC. 107.3.4.2 CITY AMENDMENTS.
  
 NOTE:
 THE REVISION FEE OF $207.00 WAS NOT PAID. NEED TO PAY
 FEE NOW BEFORE ANY ADDITIONAL REVIEW IS PERFORMED.
 ADDITIONAL FEES WILL BE CHARGED ON EVERY RE-SUBMITTALS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2018-02-05 Cont ID  
Sent By jgomez Date 2018-02-05 Time 16:43 Rev Time 0.00
Received By jgomez Date 2018-02-01 Time 10:43 Sent To  
Notes
2018-02-02 10:43:45RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2018-02-02 Cont ID  
Sent By jgomez Date 2018-01-30 Time 11:16 Rev Time 0.00
Received By lmarchan Date 2018-01-30 Time 11:02 Sent To  
Notes
2018-01-30 11:02:5201/30/18
 RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL
 FROM QUICKCALCS.
 (ENERGY CALCULATIONS AND EQUIPMENT SIZING
 CALCULATIONS). JG.

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2018-01-29 Cont ID  
Sent By jgomez Date 2018-01-29 Time 14:10 Rev Time 0.00
Received By jgomez Date 2018-01-29 Time 14:09 Sent To  
Notes
2018-01-29 14:09:3701/29/18
 RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL
 FROM QUICKCALCS.
 (ENERGY CALCULATIONS AND EQUIPMENT SIZING
 CALCULATIONS). JG.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2018-01-26 Cont ID  
Sent By jgomez Date 2018-01-26 Time 17:13 Rev Time 0.00
Received By jgomez Date 2018-01-26 Time 14:38 Sent To  
Notes
2018-01-26 14:39:33RECEIVED E-MAIL FROM NICOLE BLACKWELL FROM QUICKCALCS.
 NEW ENERGY CALCULATIONS AND LOAD CALCULATIONS. JG.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2018-01-17 Cont ID  
Sent By jgomez Date 2018-01-17 Time 11:52 Rev Time 0.00
Received By jgomez Date 2018-01-12 Time 11:25 Sent To  
Notes
2018-01-16 11:25:48RESUB OF REVISION ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-12-28 Cont ID  
Sent By jgomez Date 2017-12-28 Time 08:58 Rev Time 0.00
Received By jgomez Date 2017-12-19 Time 15:36 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-11-15 Cont ID  
Sent By jgomez Date 2017-11-15 Time 15:32 Rev Time 0.00
Received By jgomez Date 2017-11-08 Time 13:14 Sent To  
Notes
2017-11-09 13:14:35RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-04 Cont ID  
Sent By jgomez Date 2017-10-04 Time 19:00 Rev Time 0.00
Received By jgomez Date 2017-09-22 Time 10:29 Sent To  
Notes
2017-09-25 10:30:03REVISION ROUTED TO JGOMEZ

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2018-02-05 Cont ID  
Sent By jgomez Date 2018-02-05 Time 16:02 Rev Time 0.00
Received By jgomez Date 2018-02-05 Time 15:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2018-02-05 Cont ID  
Sent By jgomez Date 2018-01-30 Time 11:11 Rev Time 0.00
Received By jgomez Date 2018-01-30 Time 11:03 Sent To  
Notes
2018-01-30 11:04:0101/30/18
 RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL
 FROM QUICKCALCS.
 (ENERGY CALCULATIONS AND EQUIPMENT SIZING
 CALCULATIONS). JG.
  
 1- REVISE A/C PLAN TO REFLECT THE NEW EQUIPMENT.
 NOTE: DON'T FORGET TO HAVE THE NAME AND SIGNATURE OF
 THE A/C CONTRACTOR RESPONSIBLE FOR THE A/C DESIGN.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status F Date 2018-01-29 Cont ID  
Sent By jgomez Date 2018-01-29 Time 14:09 Rev Time 0.00
Received By jgomez Date 2018-01-29 Time 13:09 Sent To  
Notes
2018-01-29 14:10:0401/29/18
 RECEIVED REVISED CALCULATIONS FROM NICOLE BLACKWELL
 FROM QUICKCALCS.
 (ENERGY CALCULATIONS AND EQUIPMENT SIZING
 CALCULATIONS). JG.
  
  
  
 EQUIPMENT SIZING CALCULATIONS REVISION COURTESY REVIEW:
 1- THE NUMBER OF PEOPLE SHOWN ON THE EQUIPMENT SIZING
 CALCULATIONS DOESN'T MATCH THE NUMBER OF PEOPLE SHOWN
 ON THE ENERGY CALCULATIONS. REVISE AS REQUIRED.
  
 NEW COMMENT:
 1- NUMBER OF PEOPLE SHOWN ON THE ENERGY CALCULATIONS
 WAS CHANGED FROM 8 PEOPLE TO 12 PEOPLE. 8 PEOPLE WAS A
 REASONABLE NUMBER OF PEOPLE FOR A 6 BEDROOM HOUSE WITH
 2 MASTER BEDROOMS. THAT'S WHY I DIDN'T SAY ANYTHING
 ABOUT THE NUMBER OF PEOPLE CONSIDERED ON THE ENERGY
 CALCULATIONS. REVISED ENERGY CALCULATIONS ARE NOW
 SHOWING 4 PEOPLE IN THE GREAT ROOM. THIS DOESN'T LOOK
 CORRECT SINCE THE NUMBER OF PEOPLE ARE ALREADY COUNTED
 IN THE BEDROOMS. REVISE AS REQUIRED. NOTE: NUMBER OF
 PEOPLE MAY AFFECT THE SIZING OF THE A/C EQUIPMENT. MAY
 BE THAT'S WHY THE EQUIPMENT SIZING CALCULATIONS ARE
 USING 12 PEOPLE INSTEAD OF 8. THE ENERGY CODE DOESN'T
 ALLOW TO USE FACTORS THAT AFFECT THE EQUIPMENT SIZING.
 SEE SEC. R403.6.1 FBC-ENERGY CONSERVATION. REVISE AS
 REQUIRED USING THE CORRECT NUMBER OF PEOPLE.
  
 2- REVISE A/C PLAN TO REFLECT THE NEW EQUIPMENT.
 NOTE: DON'T FORGET TO HAVE THE NAME AND SIGNATURE OF
 THE A/C CONTRACTOR RESPONSIBLE FOR THE A/C DESIGN.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2018-01-26 Cont ID  
Sent By jgomez Date 2018-01-26 Time 17:13 Rev Time 0.00
Received By jgomez Date 2018-01-26 Time 17:11 Sent To  
Notes
2018-01-26 17:13:12RECEIVED E-MAIL FROM NICOLE BLACKWELL FROM QUICKCALCS.
 NEW ENERGY CALCULATIONS AND EQUIPMENT SIZING
 CALCULATIONS. JG.
  
  
 EQUIPMENT SIZING CALCULATIONS COURTESY REVIEW:
 1- CORRECT ADDRESS IS 5401 S. OLIVE AVE NOT 541
 2- TYPICALLY, THE SAME PERSON DOING THE ENERGY
 CALCULATIONS TRANSFER THE INFORMATION TO DO THE
 EQUIPMENT SIZING CALCULATIONS. ENERGY CALCULATIONS NEED
 TO BE CORRECTED TO THE ACTUAL ORIENTATION OF THE
 BUILDING. THEREFORE, EQUIPMENT SIZING CALCULATIONS NEED
 TO BE REVISED ALSO REFLECTING THE ACTUAL ORIENTATION OF
 THE BUILDING.
 3- THE NUMBER OF PEOPLE SHOWN ON THE EQUIPMENT SIZING
 CALCULATIONS DOESN'T MATCH THE NUMBER OF PEOPLE SHOWN
 ON THE ENERGY CALCULATIONS. REVISE AS REQUIRED.
 4- REVISE A/C PLAN TO REFLECT THE NEW EQUIPMENT.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2018-01-17 Cont ID  
Sent By jgomez Date 2018-01-17 Time 11:51 Rev Time 0.00
Received By jgomez Date 2018-01-17 Time 11:51 Sent To  
Notes
2018-01-17 11:52:46RESIDENTIAL (R3) REVISION FOURTH MECHANICAL REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE: REVISION FEES APPLY ON EVERY RE-SUBMITTAL.
  
  
 ORIGINAL COMMENT:
 1- A/C EQUIPMENT SIZING CALCULATIONS SUBMITTED: PROVIDE
 COMPLETE EQUIPMENT SIZING CALCULATIONS "BASED ON
 BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE
 BUILDING" AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED. ONLY THE
 SUMMARY PAGES WERE SUBMITTED. NEED THE COMPLETE
 EQUIPMENT SIZING CALCULATIONS WORKSHEETS.
  
  
 RESPONSE:
 SAME SUMMARY CALCULATIONS WERE RE-SUBMITTED AGAIN. NEED
 TO PROVIDE COMPLETE WORKSHEETS TO VERIFY HOW THE
 EQUIPMENT WAS SIZED.
 THIS WAS REQUIRED FROM THE BEGINNING OF THE MECHANICAL
 REVIEWS BECAUSE IT LOOKS LIKE THE ORIGINAL CALCULATIONS
 WERE DONE BASED ON THE BUILDING ORIENTATION WORST CASE
 SCENARIO. BY DOING THIS THE EQUIPMENT MAY BE
 OVER-SIZED. SEC. R403.6.1 FBC-ENERGY CONSERVATION, 5TH
 EDITION (2014) REQUIRES CALCULATIONS TO BE DONE ON THE
 ACTUAL ORIENTATION OF THE BUILDING AND DOESN'T ALLOW
 EQUIPMENT OVERSIZING. BASED ON THE CALCULATIONS
 SUBMITTED, THE TOTAL COOLING LOAD IS 32924. SEC.
 R403.6.1.1 ALLOWS NOT MORE THAN 1.15 TIMES EQUIPMENT
 SIZING GREATER THAN THE CALCULATED LOAD. THEREFORE, THE
 EQUIPMENT SIZE SHOULD BE 3 TON. NOT 3.5 TON AS SHOWN ON
 LOAD CALCULATIONS SUBMITTED. THIS ISSUE WAS NOT
 VERIFIED BEFORE, BECAUSE THE ORIGINAL REQUEST TO
 PROVIDE COMPLETE REPORT WAS NEVER ADDRESSED.
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2017-12-28 Cont ID  
Sent By jgomez Date 2017-12-28 Time 08:52 Rev Time 0.00
Received By jgomez Date 2017-12-28 Time 08:52 Sent To  
Notes
2017-12-27 15:45:42RESIDENTIAL (R3) REVISION THIRD MECHANICAL REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE: REVISION FEES APPLY ON EVERY RE-SUBMITTAL.
  
  
 1- A/C EQUIPMENT SIZING CALCULATIONS SUBMITTED: PROVIDE
 COMPLETE EQUIPMENT SIZING CALCULATIONS "BASED ON
 BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE
 BUILDING" AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED. ONLY THE
 SUMMARY PAGES WERE SUBMITTED. NEED THE COMPLETE
 EQUIPMENT SIZING CALCULATIONS WORKSHEETS.
  
 2- REVISED A/C PLAN ON SHEET 8.1 NEEDS THE NAME AND
 SIGNATURE OF THE A/C CONTRACTOR WHO SIGNED THE APPROVED
 PLAN AS REQUIRED BY SEC. 107.2.1 CITY AMENDMENTS. NOTE:
 APPROVED PLAN WAS SIGNED BY THE A/C CONTRACTOR MAX AIR
 COOLING, LLC.
  
 3- OWES $154.50 FOR REVISION RE-SUBMITTAL FEES. NOTE:
 REVISION FEES APPLY ON EVERY RE-SUBMITTAL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-11-15 Cont ID  
Sent By jgomez Date 2017-11-15 Time 15:24 Rev Time 0.00
Received By jgomez Date 2017-11-15 Time 07:57 Sent To I
Notes
2017-11-15 12:03:11RESIDENTIAL (R3) REVISION SECOND MECHANICAL REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
  
 1- A/C EQUIPMENT SIZING CALCULATIONS SUBMITTED: PROVIDE
 COMPLETE EQUIPMENT SIZING CALCULATIONS "BASED ON
 BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE
 BUILDING" AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 NOTE: IT LOOKS LIKE THE EQUIPMENT SIZING CALCULATIONS
 WERE DONE BY THE SAME PERSON WHO DID THE ENERGY
 CALCULATIONS. THE ENERGY CALCULATIONS NEED TO BE
 REVISED. SEE BUILDING REVIEW COMMENTS ON ITEM #1 AND
 REVISE A/C EQUIPMENT SIZING CALCULATIONS AS REQUIRED.
  
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED. SAME
 CALCULATIONS DATED AUGUST 25TH 2017 WERE SUBMITTED.
 AND, ONLY THE SUMMARY PAGES WERE SUBMITTED. NEED THE
 COMPLETE EQUIPMENT SIZING CALCULATIONS. IN ADDITION,
 THE ENERGY CALCULATIONS WERE REVISED ON 10/23/17
 SHOWING THE ACTUAL ORIENTATION OF THE BUILDING, BUT THE
 EQUIPMENT SIZING CALCULATIONS WERE NOT REVISED.
 PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS BASED ON
 THE ACTUAL ORIENTATION OF THE BUILDING AS REQUIRED BY
 SEC. R403.6.1 FBC-ENERGY CONSERVATION.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-10-04 Cont ID  
Sent By jgomez Date 2017-10-04 Time 18:59 Rev Time 0.00
Received By jgomez Date 2017-10-04 Time 18:58 Sent To  
Notes
2017-10-04 19:00:29RESIDENTIAL (R3) REVISION MECHANICAL REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
  
 1- A/C EQUIPMENT SIZING CALCULATIONS SUBMITTED: PROVIDE
 COMPLETE EQUIPMENT SIZING CALCULATIONS "BASED ON
 BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE
 BUILDING" AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 NOTE: IT LOOKS LIKE THE EQUIPMENT SIZING CALCULATIONS
 WERE DONE BY THE SAME PERSON WHO DID THE ENERGY
 CALCULATIONS. THE ENERGY CALCULATIONS NEED TO BE
 REVISED. SEE BUILDING REVIEW COMMENTS ON ITEM #1 AND
 REVISE A/C EQUIPMENT SIZING CALCULATIONS AS REQUIRED.
  
  
 NOTE:
 THE REVISION FEE OF $207.00 WAS NOT PAID. NEED TO PAY
 FEE NOW BEFORE ANY ADDITIONAL REVIEW IS PERFORMED.
 ADDITIONAL FEES WILL BE CHARGED ON EVERY RE-SUBMITTALS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]