Plan Review Details - Permit 17090424
| Plan Review Stops For Permit 17090424 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-10-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-10-17 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-10-17 |
Time |
06:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-27 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-09-27 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-10-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-17 |
Time |
06:31 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-17 |
Time |
06:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-10-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-04 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-04 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2017-10-04 07:34:49 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN | | | PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS | | | 471.003(2)(H); 471.025; FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-10-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-10-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-10-17 |
Time |
17:23 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-09-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-09-26 |
Time |
11:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-10-18 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-10-18 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-10-12 |
Time |
13:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-10-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-10-04 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-20 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-10-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-10-17 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-10-17 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-10-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-10-04 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-10-04 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2017-10-04 12:30:19 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE PERMIT APPLICATION STATES UNDER WORK DESCRIPTION | | | , RELOCATE DRAIN PLEASE SHOW ON PLAN WHAT DRAIN IS TO | | | BE RELOCATED EXISTING LOCATION AND PROPOSED LOCATION. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |