Plan Review Details - Permit 17090391
Plan Review Stops For Permit 17090391
Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2017-09-26 Time   Rev Time 0.00
Received By cpuell Date 2017-09-19 Time 18:34 Sent To M
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-03-26 Cont ID  
Sent By skennedy Date 2018-03-26 Time 08:48 Rev Time 0.00
Received By skennedy Date 2018-03-26 Time 08:48 Sent To  
Notes
2018-03-26 08:57:10****PROVISO****
 ****ISSUED AT APPLICANT'S RISK****
  
 VERIFY THAT THE NEW AC CLOSET IS IN COMPLIANCE WITH
 SECTION M1305.1.1 FBC-14 RESIDENTIAL: 3" CLEARANCE
 ALONG THE SIDES, BACK AND TOP WITH THE TOTAL WIDTH OF
 THE ENCLOSING SPACE BEING AT LEAST 12" WIDER THAN THE
 AIR HANDLER.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-09-26 Cont ID  
Sent By ccole Date 2017-09-26 Time 08:25 Rev Time 0.00
Received By ccole Date 2017-09-26 Time 08:25 Sent To  
Notes
2017-09-26 08:30:551ST REVIEW FBC-2014 RESIDIENTIAL MECHANICAL
 PERMIT #17090391
 9/26/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE PALM BEACH COUNTY APPRAISERS REPORT INDICATES
 THE RESIDENCE HAS NEVER HAD AN AC SYSTEM, AND THERE IS
 NO RECORD OF A PERMIT FOR A SYSTEM IN THE CITY PERMIT
 FILES. REFER TO SECTION R101.4.5 ENERGY CONSERVATION
 AND SUBMIT AN ENERGY EFFICIENCY COMPLIANCE REPORT FOR
 THE NEW CONDITIONED RESIDENCE.
  
 2) VERIFY THAT THE NEW AC CLOSET IS IN COMPLIANCE WITH
 SECTION M1305.1.1 FBC-14 RESIDENTIAL: 3" CLEARANCE
 ALONG THE SIDES, BACK AND TOP WITH THE TOTAL WIDTH OF
 THE ENCLOSING SPACE BEING AT LEAST 12" WIDER THAN THE
 AIR HANDLER.
  
 2) PROVIDE AN ELECTRICAL PLAN.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER