Plan Review Details - Permit 17090231
Plan Review Stops For Permit 17090231
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-07-10 Cont ID  
Sent By rgathrig Date 2018-07-10 Time 11:48 Rev Time 0.00
Received By rgathrig Date   Time   Sent To  
Notes
2018-07-10 11:48:48PROVISO FOR SOUND TRANSMISSION TEST VERIFICATION WAS
 SUBMITTED/APPROVED UNDER 17110020 (REG)

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-11-16 Cont ID  
Sent By jwitmer Date 2017-11-16 Time 16:22 Rev Time 0.00
Received By jwitmer Date 2017-11-16 Time 08:24 Sent To  
Notes
2017-11-16 16:22:272014 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 17090231
 W. P. B. PERMIT: 15111020
 ADD: 1100 S. FLAGLER DR. SUITE: UNIT 16B
 CONT: SUFFOLK
 TEL: 561-827-3678
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 SUBJECT TO FAIR HOUSING!
  
 2ND REVIEW
 DATE: THURS. NOV. 16/ 2017
 ACTION: BUILDING PROVISO
  
 1) ) SUFFOLK CONSTRUCTION TO CONDUCT SITE TESTING FOR
 COMPLIANCE WITH THE 2010 FBC-B SECTIONS:
 FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FBC-B 2010 1207.2 AIR-BORNE SOUND.
 FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 THE SOUND TESTS WILL BE CONDUCTED ON A 10 INCH CONCRETE
 SLAB UNDER THE MAIN PERMIT (15111020) AND SUBMITTED AS
 SOON AS RESULTS ARE PRINTED AND REVIEWED BY THE
 DESIGNER OF RECORD.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-10-07 Cont ID  
Sent By jwitmer Date 2017-10-07 Time 11:15 Rev Time  
Received By jwitmer Date 2017-10-07 Time 10:45 Sent To  
Notes
2017-10-07 11:12:462014 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 17090231
 W. P. B. PERMIT: 15111020
 ADD: 1100 S. FLAGLER DR. SUITE: UNIT 16B
 CONT: SUFFOLK
 TEL: 561-827-3678
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 SUBJECT TO FAIR HOUSING!
  
 1ST REVIEW
 DATE: SAT. OCT. 07/ 2017
 ACTION: DENIED
  
 1) SHEET 126-42-A2-90-16B. UNIT 16B:
  
 1A) IN THE MASTER BEDROOM BOTH THE MR. & MRS. CLOSETS
 HAVE POCKET DOORS (U05B). PLEASE SHOW COMPLIANCE WITH:
  
 1A)(1) POCKET DOORS SHOWN IN THE OPEN POSITION MEASURE
 2.50 FT. FAIR HOUSING REQUIRES A CLEAR WIDTH OF 32
 INCHES. 2014 FBC- ACCESSIBILITY/ FAIR HOUSING SECTION
 100.205.(C)(2)(2).
  
 1A)(2) PLEASE PROVIDE WHAT TYPE OF HANDLES WILL BE
 INSTALLED ON THE POCKET DOORS CANNOT BE FULLY RECESSED
 HARDWARE HAS TO BE ACCESSIBLE FOR PEOPLE THAT HAVE
 LIMITED HAND MOBILITY.
 2014 FBC- ACCESSIBILITY/ FAIR HOUSING SECTION
 100.205.(C)(2)(2).FIGURE 1( C ).
  
 1B) MASTER BATH HIS BATH THE ENTRY DOOR IS A POCKET
 DOOR PLEASE SHOW COMPLIANCE WITH:
 1B)(1) POCKET DOORS SHOWN IN THE OPEN POSITION MEASURE
 2.50 FT. FAIR HOUSING REQUIRES A CLEAR WIDTH OF 32
 INCHES. 2014 FBC- ACCESSIBILITY/ FAIR HOUSING SECTION
 100.205.(C)(2)(2).
  
 1B)(2) PLEASE PROVIDE WHAT TYPE OF HANDLES WILL BE
 INSTALLED ON THE POCKET DOORS CANNOT BE FULLY RECESSED
 HARDWARE HAS TO BE ACCESSIBLE FOR PEOPLE THAT HAVE
 LIMITED HAND MOBILITY.
 2014 FBC- ACCESSIBILITY/ FAIR HOUSING SECTION
 100.205.(C)(2)(2).FIGURE 1( C ).
  
 2) SHEET 242-42-A6-66-16B. UNIT 16B. FINISHES. FLOOR
 FINISHES. BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION
 (FBC-B 2010) FOR TILE, STONE, MARBLE, VINYL AND WOOD
 FLOORING ALL NEED TO HAVE HAD THE SOUND UNDERLAYMENT
 TESTED FLOOR ASSEMBLIES TO THE FOLLOWING STANDARDS AND
 MEET THE QUALIFICATIONS LISTED UNDER EACH OF THE
 STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/ NO
 DROPPED CEILING OR PROVIDE TESTING FOR THE THICKNESS
 FOR THE SLAB AND IF THERE IS A DROP CEILING WITH OR
 WITHOUT INSULATION OR PROVIDE ONSITE TESTING TO THE
 LISTED BELOW ASTM STANDARDS:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
  
 2A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 2B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-10-27 Cont ID  
Sent By jleahy Date 2017-10-27 Time 15:55 Rev Time 0.00
Received By jleahy Date 2017-10-27 Time 12:52 Sent To  
Notes
2017-10-20 15:56:59FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 PLANS ARE NOT CLOUDED FOR THE REVISION.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-10-06 Cont ID  
Sent By pleduc Date 2017-10-06 Time   Rev Time 0.00
Received By pleduc Date 2017-10-06 Time 12:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2017-12-27 Time   Rev Time 0.00
Received By cpuell Date 2017-12-12 Time 16:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-11-29 Cont ID  
Sent By gjohnson Date 2017-11-29 Time 10:13 Rev Time 0.00
Received By gjohnson Date 2017-11-07 Time 13:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-20 Cont ID  
Sent By jleahy Date 2017-10-20 Time 15:57 Rev Time 0.00
Received By jleahy Date 2017-10-04 Time 11:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-12-27 Cont ID  
Sent By ccole Date 2017-12-27 Time 15:00 Rev Time 0.00
Received By ccole Date 2017-12-27 Time 14:45 Sent To  
Notes
2017-12-27 15:16:22MECHANICAL PROVISO:
  
 THE MECHANICAL PLAN WAS APPROVED WITHOUT REVIEW OF THE
 REVISED RCP PLAN SHEET- A7.55A WHICH WAS PREVIOUSLY
 REQUESTED BUT NOT PROVIDED FOR A SECOND TIME.
  
 CCOLE- 12/27/17

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-11-17 Cont ID  
Sent By ccole Date 2017-11-17 Time 17:11 Rev Time 0.00
Received By ccole Date 2017-11-17 Time 17:11 Sent To  
Notes
2017-11-17 17:40:252ND REVIEW FBC-2014 MECHANICAL
 PERMIT #17090231
 11/17/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A7-55-A WAS NOT UPLOADED FOR REVIEW. SHEET
 A7-55-A APPARENTLY IS AN ARCHITECTURAL REFLECTIVE
 CEILING (RCP) PLAN THAT THE DESIGN TEAM HAS CHOSEN TO
 REVISE TO MATCH THE REVISED MECHANICAL PLAN M2-90-16B
 WHICH SHOWS THE CHANGE TO LINEAR DIFFUSERS. THE
 REVISION TO THE ARCHITECTURAL RCP SHEET WAS STATED
 FIRST IN THE UPLOADED MECHANICAL NARRATIVE DATED
 10/3/17, AND
  
 FOR A SECOND TIME IN THE CURRENT UPLOADED MECHANICAL
 NARRATIVE DATED 11/7/17. APPARENTLY THE DESIGN TEAM HAS
 CHOSEN TO REVISE THE RCP PLANS FOR THIS UNIT AS THEY
 HAVE DONE WITH MANY OF THE OTHER UNITS FOR COORDINATION
 PURPOSES. MANY OF THOSE REVISIONS HAVE BEEN REVIEWED
 AND APPROVED BECAUSE THE REVISED SHEETS WERE PROVIDED.
 IN ORDER TO FINALIZE THIS REVISION, PLEASE
  
 REVIEW THE SUBMITTED NARRATIVES AND THE UPLOADED PLANS
 AND PROVIDE THE MISSING PLAN SHEET. PLEASE NOTE THAT
 THE REVISED MECHANICAL PLAN SHEET M2-90-16B DATED
 11/7/17 HAS NO ROOM IDENTIFICATIONS WHEREAS THE
 PREVIOUSLY REVISED SHEET DATED 10/3/17 SHOWED THOSE
 IDENTIFICATIONS.
  
 IF THERE IS ANYTHING ELSE I CAN DO TO HELP PLEASE
 CONTACT ME.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-10-19 Cont ID  
Sent By ccole Date 2017-10-19 Time 15:36 Rev Time 0.00
Received By ccole Date 2017-10-19 Time 11:53 Sent To  
Notes
2017-10-19 15:40:111ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17090231
 10/19/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE REVISED RCP PLAN WAS NOT UPLOADED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-11-29 Cont ID  
Sent By gjohnson Date 2017-11-29 Time 10:10 Rev Time 0.00
Received By gjohnson Date 2017-11-29 Time 10:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-10-13 Cont ID  
Sent By gjohnson Date 2017-10-13 Time 11:16 Rev Time 0.00
Received By gjohnson Date 2017-10-13 Time 11:16 Sent To  
Notes
2017-10-13 11:31:211ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. PROVIDE ENLARGED FLOOR PLAN FOR BATHROOM #2 TO SHOW
 CLEAR FLOOR SPACE AND BACKING FOR THE SHOWER IN
 COMPLIANCE WITH SPEC B FHA. AS INDICATED ON SHT. A0.41
 ON APPROVED PLAN 15111020
  
 2. SHT. P2-90-16B BATHROOM #2 SHOWER IS LABELED AS TUB
 PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1
  
 3. SHT. P2-90- 16B WATER PIPING IS SHOWN ON THE
 OPPOSITE END OF SHOWER AS CONTROLS. THE CONTROLS SHALL
 REMAIN ON RIGHT HAND END OF TUB TO COMPLY WITH FHA.
 PLEASE CLARIFY PER PER WPB AMEND TO FBC 107.2.1
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2017-12-27 Cont ID  
Sent By cpuell Date 2017-12-27 Time 16:03 Rev Time 0.00
Received By cpuell Date 2017-12-27 Time 16:03 Sent To  
Notes
2017-12-27 15:23:31MECH DIG-SIG GOOD- CCOLE-12/27/17
2017-11-29 10:11:38PLUMB DIG SIG GOOD/GPJ 11/29/17
2017-11-16 16:26:14ARCHITECTURAL SHEETS CHECKED FOR DIGITAL SIGNATURES. JW
 11/16/17

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2017-10-27 Cont ID  
Sent By jleahy Date 2017-10-27 Time 12:52 Rev Time 0.00
Received By jleahy Date 2017-10-27 Time 12:52 Sent To  
Notes
2017-10-19 15:42:10SHEET M2.90-16B NO DIG/SIG- CCOLE-10/19/17
2017-10-07 11:15:58ARCHITECTS SIGNATURE OK. JW