| Plan Review Stops For Permit 17090199 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-02-27 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-27 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-27 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2018-02-27 11:40:17 | PROVISO: | | | PRIOR TO CONCRETE POUR, A "BUILDING UNDER CONSTRUCTION" | | | (FORM BOARD) ELEVATION CERTIFICATE IS REQUIRED. | | | PRIOR TO FINAL INSPECTION, A "FINISHED CONSTRUCTION" | | | ELEVATION CERTIFICATE IS REQUIRED. THE FINISHED | | | CONSTRUCTION ELEVATION CERTIFICATE MAY BE SENT VIA | | | EMAIL FOR PRELIMINARY REVIEW. A SIGNED AND SEALED | | | ORIGINAL FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | TO BE SUBMITTED AT THE BUILDING DIVISION, REVIEWED AND | | | APPROVED PRIOR TO FINAL INSPECTION. THIS SHOULD BE DONE | | | AS EARLY AS POSSIBLE AFTER FINAL GRADE IS COMPLETE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-14 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-27 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2018-02-14 13:39:33 | ****CORRECTIONS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 2/26/18 NEW COMMENT: | | | | | | THRESHOLD | | | | | | THRESHOLD BUILDINGS | | | | | | 1. SPECIAL INSPECTOR AGREEMENT SHALL BE COMPLETED AND | | | SUBMITTED IN TRIPLICATE. | | | 2. PROVIDE RESUME OF JOB INSPECTOR (P.E., ARCH. OR 468 | | | INSPECTOR). | | | 3. PROVIDE LIST OF SIMILAR PROJECTS COMPLETED BY | | | CONTRACTOR. | | | 4. PROVIDE STRUCTURAL INSPECTION PLAN. | | | 5. THIS BUILDING MEETS THE DEFINITION OF: THRESHOLD | | | BUILDING F.S. 553.71 (12) | | | | | | ?THRESHOLD BUILDING? ANY BUILDING WHICH IS GREATER THAN | | | (3) STORIES OR 50 FT. IN HEIGHT OR WHICH HAS AN | | | ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN | | | AREA AND HAS AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | | | | 5A) THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL | | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS PURSUANT TO | | | A STRUCTURAL INSPECTION PLAN PREPARED BY THE ENGINEER | | | OF RECORD. THE STRUCTURAL INSPECTION PLAN MUST BE | | | SUBMITTED TO THE ENFORCING AGENCY PRIOR TO THE ISSUANCE | | | OF A BUILDING PERMIT. | | | | | | 5B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUESTS FOR THRESHOLD | | | BUILDINGS, A SPECIAL INSPECTOR IS REQUIRED BY F.S. | | | 553.79 (5) TO THE MINIMUM INSPECTIONS REQUIRED BY THIS | | | CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED TO BE | | | FILLED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED AND | | | RETURNED TO THIS OFFICE AND REVIEWED AND APPROVED | | | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. CONTACT KEN | | | CONRAD, MANAGER OF SPECIAL INSPECTOR PROGRAM AT (561) | | | 805-6666 FOR FURTHER INFORMATION BEFORE THE PERMIT MAY | | | BE ISSUED. | | | | | | 5C) MISSING STATEMENT. THRESHOLD BUILDING, REQUIRED. | | | W.P.B. AMENDMENT 110.3.7.4.4. ALL PLANS FOR THE | | | BUILDING WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY | | | THE ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, ?TO THE BEST OF THE ARCHITECT?S OR ENGINEER?S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE | | | LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | F.S.? | | | | | | | | | SECOND REVIEW: | | | | | | PARTIALLY COMPLIED: | | | | | | 1. ACTUAL BUILDING AREA SHOWN. INCLUDE THE BREAKDOWN OF | | | THE ASSEMBLY OCCUPANCY. | | | | | | OCCUPANCY CLASSIFICATIONS, SF FOR EACH OCC CLASS, | | | OCCUPANT LOAD PER OCCUPANCY | | | | | | IF ASSEMBLY OCCUPANT LOAD EXCEEDS 500 SF, THIS IS A | | | THRESHOLD BUILDING PER FS553.71(12) AND THE STATEMENT | | | REQUIRED BY FS553.79 IS TO BE INCLUDED ON THE PLAN. | | | | | | | | | | | | PENDING THE ABOVE ASSEMBLY CALCULATIONS | | | | | | 2. A RESIDENT INSPECTOR MAY BE REQUIRED, FBC 110.3.9 | | | (IF THIS BUILDING IS NOT A THRESHOLD BUILDING). IS | | | APPLICANT'S INTENT TO USE A RESIDENT INSPECTOR, | | | ESPECIALLY SINCE THE OTHER TWO BUILDINGS IN THIS | | | PROJECT REQUIRE A THRESHOLD INSPECTOR? | | | | | | | | | | | | COMPLIED WITH AN ADDITONAL NOTES. | | | | | | A. SIGNATURE NOT PROVIDED ON SEAL ON PAGE S0.0.1 | | | B. ONE SET MISSING PAGE S0.0.1 | | | | | | | | | FBC-107.1 GENERAL - FAC 61G1-16.004 - A TITLE BLOCK | | | MUST APPEAR ON ALL ARCHITECTURAL OR INTERIOR DESIGN | | | DRAWINGS AND SPECIFICATION IDENTIFICATION SHEETS THAT | | | ARE REQUIRED TO BE SIGNED AND SEALED. THE TITLE BLOCK | | | MUST, AT A MINIMUM, CONTAIN THE FOLLOWING INFORMATION: | | | | | | 3. S0.0.1, REVISE NOTE WHICH REFERS TO SOILS REPORT TO | | | INCLUDE REVISION DATED 2/15/2017. | | | | | | | | | | | | NOTED, WILL BE ISSED WITH PROVISO WHEN READY. | | | | | | 4. THIS PERMIT WILL BE ISSUED WITH PROVISO: | | | | | | THIS PARCEL IS LOCATED IN SFHA A5 WITH A BFE OF 7.0' | | | NGVD29. PROPOSED FFE IS 9.0' NGVD29. | | | | | | PRIOR TO CONCRETE POUR, A "BUILDING UNDER CONSTRUCTION" | | | (FORM BOARD) ELEVATION CERTIFICATE IS REQUIRED. | | | | | | PRIOR TO FINAL INSPECTION, A "FINISHED CONSTRUCTION" | | | ELEVATION CERTIFICATE IS REQUIRED. THE FINISHED | | | CONSTRUCTION ELEVATION CERTIFICATE MAY BE SENT VIA | | | EMAIL FOR PRELIMINARY REVIEW. A SIGNED AND SEALED | | | ORIGINAL FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | TO BE SUBMITTED AT THE BUILDING DIVISION, REVIEWED AND | | | APPROVED PRIOR TO FINAL INSPECTION. THIS SHOULD BE DONE | | | AS EARLY AS POSSIBLE AFTER FINAL GRADE IS COMPLETE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-25 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-09-22 |
Time |
17:54 |
Sent To |
|
|
| Notes |
| 2017-09-25 17:00:19 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. REVISE PLAN TO INCLUDE THE FOLLOWING INFORMATION, | | | FBC 107: | | | BUILDING CONSTRUCTION TYPE | | | SQUARE FOOT AREA OF EACH STORY | | | OCCUPANCY CLASSIFICATIONS, SF FOR EACH OCC CLASS, | | | OCCUPANT LOAD PER OCCUPANCY | | | | | | IF ASSEMBLY OCCUPANT LOAD EXCEEDS 500 SF, THIS IS A | | | THRESHOLD BUILDING PER FS553.71 AND THE STATEMENT | | | REQUIRED BY FS553.79 IS TO BE INCLUDED ON THE PLAN. | | | | | | 2. A RESIDENT INSPECTOR MAY BE REQUIRED, FBC 110.3.9 | | | (IF THIS BUILDING IS NOT A THRESHOLD BUILDING). IS | | | APPLICANT'S INTENT TO USE A RESIDENT INSPECTOR, | | | ESPECIALLY SINCE THE OTHER TWO BUILDINGS IN THIS | | | PROJECT REQUIRE A SPECIAL INSPECTOR? | | | | | | 3. S0.0.1, REVISE NOTE WHICH REFERS TO SOILS REPORT TO | | | INCLUDE REVISION DATED 2/15/2017. | | | | | | 4. THIS PERMIT WILL BE ISSUED WITH PROVISO: | | | | | | THIS PARCEL IS LOCATED IN SFHA A5 WITH A BFE OF 7.0' | | | NGVD29. PROPOSED FFE IS 9.0' NGVD29. | | | | | | PRIOR TO CONCRETE POUR, A "BUILDING UNDER CONSTRUCTION" | | | (FORM BOARD) ELEVATION CERTIFICATE IS REQUIRED. | | | | | | PRIOR TO FINAL INSPECTION, A "FINISHED CONSTRUCTION" | | | ELEVATION CERTIFICATE IS REQUIRED. THE FINISHED | | | CONSTRUCTION ELEVATION CERTIFICATE MAY BE SENT VIA | | | EMAIL FOR PRELIMINARY REVIEW. A SIGNED AND SEALED | | | ORIGINAL FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | TO BE SUBMITTED AT THE BUILDING DIVISION, REVIEWED AND | | | APPROVED PRIOR TO FINAL INSPECTION. THIS SHOULD BE DONE | | | AS EARLY AS POSSIBLE AFTER FINAL GRADE IS COMPLETE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-02-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-08 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-08 |
Time |
06:44 |
Sent To |
|
|
| Notes |
| 2018-02-27 14:11:34 | RECEIVED CORRECTION AND CHANGED STATUS TO PASSED. | | | | | | | | 2018-02-08 10:39:59 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | THIS REVIEW FOR FOUNDATION PERMIT ONLY. | | | | | | RESPONSE LETTER STATED THAT SHEET E3.0.0 WAS PROVIDED | | | TO ADDRESS COMMENTS. HOWEVER, THE SHEET WAS ONLY | | | PROVIDED FOR 2 OF THE 3 SETS. THIS SHEET IS REQUIRED | | | FOR EACH SET. (FBC 107.2.1) THE PREVIOUS COMMENT IS | | | LISTED BELOW, AND THERE IS A NEW COMMENT THAT FOLLOWS | | | BASED ON THE SUBMISSION PROVIDED. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, WIRE AND BREAKER SIZES FOR SERVICE. | | | SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM BONDING | | | TERMINATION POINT. NEC 215.5, 230, 250.50, 250.94, | | | 408.30, 695.3; FBC 107.2.1 | | | | | | NEW COMMENT: | | | | | | 2. PLAN STATES THAT THE FEED TO THE RETAIL WIREWAY IS 2 | | | SETS OF 500 KCMIL ALUMINUM, WHICH IS RATED FOR A TOTAL | | | OF 620 AMPS. THIS WIRE WILL BE FUSED AT 800 AMPS, SO | | | THE WIRE IS UNDERSIZED. PROVIDE CORRECTION. THIS | | | COMMENT WILL NOT HOLD UP THE FOUNDATION PERMIT, BUT | | | NEEDS TO BE CORRECTED. NEC 310.15(B)(16) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-26 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-26 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2017-09-26 08:46:17 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | THIS REVIEW FOR FOUNDATION PERMIT ONLY. | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, WIRE AND BREAKER SIZES FOR SERVICE. | | | SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM BONDING | | | TERMINATION POINT. NEC 215.5, 230, 250.50, 250.94, | | | 408.30, 695.3; FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
squinone |
Date |
2018-01-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
squinone |
Date |
2018-01-29 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-01-29 10:58:44 | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED FROM THE FOLLOWING WEBSITE LINK: HTTP | | | ://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,- | | | PERMITS-APPLICATIONS | | | | | | 2. PLEASE SUBMIT THE LATEST VERSION OF THE 'AUTO-CALC | | | CERTIFIED COST ESTIMATE FORM' FOR SUBMISSION TO CITY OF | | | WEST PALM BEACH PUBLIC WORKS DEPARTMENT FOR ADDITIONAL | | | WORK PROPOSED. THIS FORM CAN BE DOWNLOADED FROM THE | | | FOLLOWING LINK: HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING- | | | PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | SOFIA QUINONES-BENEJAM, EI | | | PROJECT ENGINEER | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33402 | | | (MAILING ADDRESS: PO BOX 3366) | | | P: 561.494.1108 | | | C: 561.459.6518 | | | F: 561.494.1116 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2017-11-01 |
|
|
Cont ID |
|
| Sent By |
squinone |
Date |
2017-11-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
squinone |
Date |
2017-10-31 |
Time |
|
Sent To |
I |
|
| Notes |
| 2017-11-01 12:58:01 | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | PROJECT NAME: FORMER CITY HALL & HELEN WILKES SITE | | | STATUS: FAILED | | | DATE: NOVEMBER 1, 2017 | | | | | | 1) ADDRESS BUILDING AND ZONING COMMENTS. | | | | | | SOFIA QUINONES-BENEJAM, EI | | | PROJECT ENGINEER | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33402 | | | (MAILING ADDRESS: PO BOX 3366) | | | P: 561.494.1108 | | | C: 561.459.6518 | | | F: 561.494.1116 | | | EMAIL: [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-01-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-01-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-01-30 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2018-01-30 16:11:57 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) ONE OF THE THREE SUBMITTAL SETS DID NOT HAVE SHEET | | | FP1.1.1 ATTACHED TO IT AS PER THE COMMENT RESPONSE # 1 | | | TO WESLEY JOLIN . | | | | | | IN AN EFFORT TO MOVE THIS PERMIT FORWARD TIS PROVISO IS | | | BEING PROVIDED. | | | | | | THE SUBMITTAL SHEET HAS A HAD WRIITEN NOTE ON SHEET CVR | | | - S INDICATING THE SAME. | | | | | | PLEASE ADD THIS SHEET. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-09-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-09-20 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-09-20 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2017-09-20 09:16:04 | 201 NORTH FLAGLER DRIVE - RESTAURANT | | | PERMIT #17090199 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | **RETAIL/RESTAURANT FOUNDATION ONLY** | | | | | | FIRE PROTECTION BACKFLOW PREVENTERS: PER NFPA 24 | | | SECTION 6.2.1, ALL CONNECTIONS TO PRIVATE FIRE SERVICE | | | MAINS FOR FIRE PROTECTION SYSTEMS SHALL BE ARRANGED IN | | | ACCORDANCE WITH ONE OF THE FOLLOWING SO THAT THEY CAN | | | BE ISOLATED: | | | (1)A POST INDICATOR VALVE INSTALLED NOT LESS THAN 40 | | | FEET FROM THE BUILDING. | | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A POST | | | INDICATOR VALVE SHALL BE PERMITTED TO BE INSTALLED | | | CLOSER THAN 40 FEET BUT AT LEAST AS FAR FROM THE | | | BUILDING AS THE HEIGHT OF THE WALL FACING THE POST | | | INDICATOR VALVE. | | | (2) A WALL POST INDICATOR VALVE | | | (3) AN INDICATING VALVE IN A PIT, INSTALLED IN | | | ACCORDANCE WITH SECTION 6.4 | | | (4) A BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING | | | VALVE NOT LESS THAN 40 FEET FROM THE BUILDING. | | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A | | | BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING VALVE | | | SHALL BE PERMITTED TO BE INSTALLED CLOSER THAN 40 FEET | | | BUT AT LEAST AS FAR FROM THE BUILDING AS THE HEIGHT OF | | | THE WALL FACING THE BACKFLOW PREVENTER. | | | (5) CONTROL VALVES INSTALLED IN A FIRE-RATED ROOM | | | ACCESSIBLE FROM THE EXTERIOR | | | (6) CONTROL VALVES IN A FIRE-RATED STAIR ENCLOSURE | | | ACCESSIBLE FROM THE EXTERIOR AS PERMITTED BY THE | | | AUTHORITY HAVING JURISDICTION | | | | | | THE CITY OF WEST PALM BEACH REQUIRES CONSTRUCTION | | | TRAILERS LARGER THAN A SINGLE "DOUBLE WIDE" (OR TWO | | | "SINGLE WIDE") TO EITHER BE PROTECTED BY AN AUTOMATIC | | | SPRINKLER SYSTEM OR COMPLY WITH THE SEPARATION | | | REQUIREMENTS OF NFPA 241. TEMPORARY CONSTRUCTION | | | TRAILERS OR MODULAR BUILDINGS WILL REQUIRE A PERMIT AND | | | COMPLIANCE WITH THE FOLLOWING: | | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2: | | | TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF | | | COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE | | | CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS, | | | TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1. | | | PER TABLE 4.2.1: | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2017-10-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-10-18 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-10-18 |
Time |
17:53 |
Sent To |
ENG |
|
| Notes |
| 2017-10-18 17:55:05 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | | | | | | | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-02-26 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-25 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-11-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-11-01 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-09-07 |
Time |
10:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
N |
Date |
2018-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-02-26 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-02-26 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2018-02-26 15:16:44 | IMPACT FEES TO BE PAID ON BUILDING PERMIT, OK PER EMAIL | | | FROM WILLIE SWOPE | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-14 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-14 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2018-02-14 13:45:01 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | | THAT FEES WERE PAID IS TO BE PROVIDED; 561-233-5025 FOR | | | MORE INFORMATION . | | | | | | IT IS POSSIBLE THAT THE COUNTY WILL ALLOW FOR IMPACT | | | FEES TO BE ASSESSED AT TIME OF VERTICAL BUILDING PERMIT | | | UPON REQUEST. PLEASE ADVISE IF YOU WOULD LIKE FOR ME TO | | | MAKE THIS REQUEST. | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-25 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-09-25 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2017-09-25 16:59:56 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | | THAT FEES WERE PAID IS TO BE PROVIDED; 561-233-5025 FOR | | | MORE INFORMATION . | | | | | | IT IS POSSIBLE THAT THE COUNTY WILL ALLOW FOR IMPACT | | | FEES TO BE ASSESSED AT TIME OF VERTICAL BUILDING PERMIT | | | UPON REQUEST. PLEASE ADVISE IF YOU WOULD LIKE FOR ME TO | | | MAKE THIS REQUEST. | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
P |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-25 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-09-25 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2017-09-25 15:18:12 | THIS PARCEL IS LOCATED IN SFHA A5 WITH A BFE OF 7.0' | | | NGVD29. PROPOSED FFE IS 9.0' NGVD29. | | | | | | PROVISO: | | | | | | PRIOR TO CONCRETE POUR, A "BUILDING UNDER CONSTRUCTION" | | | (FORM BOARD) ELEVATION CERTIFICATE IS REQUIRED. | | | | | | PRIOR TO FINAL INSPECTION, A "FINISHED CONSTRUCTION" | | | ELEVATION CERTIFICATE IS REQUIRED. THE FINISHED | | | CONSTRUCTION ELEVATION CERTIFICATE MAY BE SENT VIA | | | EMAIL FOR PRELIMINARY REVIEW. A SIGNED AND SEALED | | | ORIGINAL FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | TO BE SUBMITTED AT THE BUILDING DIVISION, REVIEWED AND | | | APPROVED PRIOR TO FINAL INSPECTION. THIS SHOULD BE DONE | | | AS EARLY AS POSSIBLE AFTER FINAL GRADE IS COMPLETE. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2018-02-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-27 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-27 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-02-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-26 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-26 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2018-02-26 14:54:22 | PROVISO: PERMIT # 17090199 | | | PLUMBING COMMENTS TO BE CORRECTED AND APPROVED REVISED | | | PLAN SHEETS ON JOBSITE FOR FIRST ROUGH INSPECTION. | | | 1. THE SANITARY ISOMETRIC DOES NOT MATCH THE FLOOR PLAN | | | IT SHOWS 2 SOIL STACKS NEAR THE ELEVATOR SUMP THAT ARE | | | NOT SHOWN ON THE FLOOR PLAN PLEASE CLARIFY. PER WPB | | | AMEND TO FBC 107.2.1 | | | 2. THE FIRST TWO SECTIONS OF 8" PIPE ON THE STORM | | | ISOMETRIC ARE UNDERSIZED THEY SHOULD BE 10". PER FBC PL | | | TABLE 1006.3 1/8' PFT | | | 3. THE NEW SHEETS P3.2.1 AND P3.3.1 ARE MISSING FROM | | | ONE OF THE PLAN SETS. PER WPB AMEND TO FBC 107.2.1 | | | 4. IF THE GREASE INTERCEPTORS ARE TO BE APPROVED UNDER | | | THIS PLAN SET PLEASE PROVIDE THE FOLLOWING. | | | A) PROVIDE SIZING CALCULATIONS FROM SCHEIR | | | MANUFACTURING FOR THE GREASE INTERCEPTORS. PER WPB | | | AMEND TO FBC 107.2.1 | | | B) SHT. PF2.1.1 A DOUBLE SANITARY TEE CANNOT BE USED AS | | | A SAMPLING PORT A PRE MANUFACTURED SAMPLING PORT OR A | | | TWO WAY CLEANOUT CAN BE USED PER WPB UTILITIES DEPT. | | | SEE STANDARD DETAIL GS 7 OR GS 7.1 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-02-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-13 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-13 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2018-02-13 11:45:57 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE SANITARY ISOMETRIC DOES NOT MATCH THE FLOOR PLAN | | | IT SHOWS 2 SOIL STACKS NEAR THE ELEVATOR SUMP THAT ARE | | | NOT SHOWN ON THE FLOOR PLAN PLEASE CLARIFY. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 2. THE FIRST TWO SECTIONS OF 8" PIPE ON THE STORM | | | ISOMETRIC ARE UNDERSIZED THEY SHOULD BE 10". PER FBC PL | | | TABLE 1006.3 1/8' PFT | | | | | | 3. THE NEW SHEETS P3.2.1 AND P3.3.1 ARE MISSING FROM | | | ONE OF THE PLAN SETS. PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. IF THE GREASE INTERCEPTORS ARE TO BE APPROVED UNDER | | | THIS PLAN SET PLEASE PROVIDE THE FOLLOWING. | | | | | | A) PROVIDE SIZING CALCULATIONS FROM SCHEIR | | | MANUFACTURING FOR THE GREASE INTERCEPTORS. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | B) SHT. PF2.1.1 A DOUBLE SANITARY TEE CAN NOT BE USED | | | AS A SAMPLING PORT A PRE MANUFACTURED SAMPLING PORT OR | | | A TWO WAY CLEANOUT CAN BE USED PER WPB UTILITIES DEPT. | | | SEE STANDARD DETAIL GS 7 OR GS 7.1 | | | | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-10-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-10-18 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-10-18 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2017-10-18 17:53:33 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE A SANITARY COLLECTION ISOMETRIC DRAWING | | | INCLUDING DFU LOAD. PER WPB AMEND TO FBC | | | 107.3.5.1.3(13) | | | | | | 2. PROVIDE A STORM DRAIN COLLECTION ISOMETRIC DRAWING | | | INCLUDING SQFT THAT IS BEING DRAINED. PER WPB AMEND TO | | | FBC 107.3.5.1.3(13) | | | | | | 3. PLEASE PLACE NOTE ON PLAN SEPARATE PERMITS ARE | | | REQUIRED FOR DOMESTIC WATER BACKFLOW AND FIRE LINE | | | BACKFLOW. PER WPB UTILITIES DEPT. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2018-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-02-26 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-02-26 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2018-02-26 15:15:08 | SHEETS S0.0.4, S0.0.5, S1.1.1 DIGITALLY SIGNED AND | | | SEALED ROUTED TO RECORDS | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
3 |
Status |
P |
Date |
2018-03-02 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-02 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-27 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2018-03-02 16:07:40 | THRESHOLD AGREEMENT REVIEWED AND APPROVED. DELIVERED | | | COPIES TO KEN CONRAD AND RICHARD GATHRIGHT. |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
F |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-14 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-14 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2018-02-14 13:43:17 | SEE BUILDING REVIEW NOTES. |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-25 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-09-25 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2017-09-25 17:00:40 | SEE BUILDING REVIEW | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-02-26 |
|
|
Cont ID |
|
| Sent By |
AA |
Date |
2018-02-26 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2018-02-26 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2018-02-26 11:57:35 | PROVISO: 1. A MINIMUM OF 8 FOOT WIDE SIDEWALK SHALL BE | | | PROVIDED AROUND THE SITE (CONTINUOUS PATH OF TRAVEL). | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-10-17 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2017-10-17 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2017-10-17 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2017-10-17 15:24:04 | FOR FOUNDATION PERMIT ONLY, PLEASE SUBMIT A CLEAR SITE | | | PLAN WITH DIMENSIONS FOR SETBACKS TO CONFIRM COMPLIANCE | | | WITH APPROVED SITE PLAN. |
|
|