Plan Review Details - Permit 17090180
Plan Review Stops For Permit 17090180
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-10-13 Cont ID  
Sent By shill Date 2017-10-13 Time 16:39 Rev Time 0.00
Received By shill Date 2017-10-13 Time 16:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-10-10 Cont ID  
Sent By shill Date 2017-10-10 Time 09:24 Rev Time 0.00
Received By shill Date 2017-10-10 Time 09:20 Sent To  
Notes
2017-10-10 09:25:16****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 COMMENTS FROM PREVIOUS LIST:
  
 1. OK
  
 2. FOR THE FLOORING UNDERLAYMENT, PROVIDE THE FOLLOWING
 TEST REPORTS:
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. OK (FLAME SPREAD TEST ON FILE)
  
 3. OK
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-09-22 Cont ID  
Sent By shill Date 2017-09-22 Time 09:18 Rev Time 0.00
Received By shill Date 2017-09-22 Time 09:12 Sent To  
Notes
2017-09-22 09:20:26****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. PLANS TO INCLUDE THE PRINTED NAME AND SIGNATURE OF
 THE INDIVIDUAL TAKING RESPONSIBILITY FOR THE DESIGN,
 FBC 107.
  
 2. FOR THE FLOORING UNDERLAYMENT, PROVIDE THE FOLLOWING
 TEST REPORTS:
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  
 3. FBC 109, VALUE IS TOO LOW. PROVIDE A COPY OF THE
 CONTRACT FOR THIS JOB, FBC 109. VALUE TO INCLUDE LABOR,
 MATERIALS, OVERHEAD, PROFIT, EVEN IF PROVIDED BY
 OTHERS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-10-16 Cont ID  
Sent By jpearson Date 2017-10-16 Time 07:21 Rev Time 0.00
Received By jpearson Date 2017-10-16 Time 07:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-09-22 Cont ID  
Sent By jpearson Date 2017-09-22 Time 07:41 Rev Time 0.00
Received By jpearson Date 2017-09-22 Time 07:41 Sent To  
Notes
2017-09-22 07:41:10CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN
 PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS
 471.003(2)(H); 471.025; FBC 107.2.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-10-10 Cont ID  
Sent By pleduc Date 2017-10-10 Time   Rev Time 0.00
Received By pleduc Date 2017-10-10 Time 14:33 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-09-25 Cont ID  
Sent By pleduc Date 2017-09-25 Time   Rev Time 0.00
Received By pleduc Date 2017-09-25 Time 12:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-10-16 Cont ID  
Sent By jpearson Date 2017-10-16 Time 07:21 Rev Time 0.00
Received By jpearson Date 2017-10-05 Time 10:27 Sent To  
Notes
2017-10-06 10:28:03B02

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-03 Cont ID  
Sent By cpuell Date 2017-10-03 Time 08:37 Rev Time 0.00
Received By cpuell Date 2017-09-06 Time 11:53 Sent To  
Notes
2017-09-07 11:53:47B24

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-10-11 Cont ID  
Sent By gjohnson Date 2017-10-11 Time 13:57 Rev Time 0.00
Received By gjohnson Date 2017-10-11 Time 11:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-10-02 Cont ID  
Sent By lcrespo Date 2017-10-02 Time 15:54 Rev Time 0.00
Received By lcrespo Date 2017-10-02 Time 15:54 Sent To  
Notes
2017-10-02 15:56:0410/2/17 LAC APPROVED SENT TO PROCESSING