Plan Review Details - Permit 17090114
Plan Review Stops For Permit 17090114
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-09-20 Cont ID  
Sent By shill Date 2017-09-20 Time 16:52 Rev Time 0.00
Received By shill Date 2017-09-20 Time 16:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-10-02 Cont ID  
Sent By jpearson Date 2017-10-02 Time 08:02 Rev Time 0.00
Received By jpearson Date 2017-10-02 Time 08:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-09-18 Cont ID  
Sent By jpearson Date 2017-09-18 Time 08:18 Rev Time 0.00
Received By jpearson Date 2017-09-18 Time 08:18 Sent To  
Notes
2017-09-18 08:18:46CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1:
 8.4.2. FBC CE 405.7.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-09-07 Cont ID  
Sent By wjolin Date 2017-09-07 Time 09:59 Rev Time 0.00
Received By wjolin Date 2017-09-07 Time 09:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-10-02 Cont ID  
Sent By jpearson Date 2017-10-02 Time 08:02 Rev Time 0.00
Received By jpearson Date 2017-09-27 Time 14:00 Sent To  
Notes
2017-09-28 14:00:14RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-09-20 Cont ID  
Sent By shill Date 2017-09-20 Time 16:52 Rev Time 0.00
Received By shill Date 2017-09-05 Time 11:24 Sent To  
Notes
2017-09-06 11:25:04B14

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2017-09-18 Cont ID  
Sent By ccole Date 2017-09-18 Time 16:49 Rev Time 0.00
Received By ccole Date 2017-09-18 Time 16:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-09-18 Cont ID  
Sent By tklarge Date 2017-09-18 Time 11:33 Rev Time 0.00
Received By tklarge Date 2017-09-18 Time 11:13 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy