Plan Review Details - Permit 17090043
Plan Review Stops For Permit 17090043
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-07-10 Cont ID  
Sent By rgathrig Date 2018-07-10 Time 11:31 Rev Time 0.00
Received By rgathrig Date   Time   Sent To  
Notes
2018-07-10 11:31:48PROVISO FOR SOUND TRANSMISSION TEST VERIFICATION WAS
 SUBMITTED/APPROVED UNDER 17110020 (REG)

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-10-23 Cont ID  
Sent By jwitmer Date 2017-10-23 Time 14:30 Rev Time 0.00
Received By jwitmer Date 2017-10-23 Time 14:05 Sent To  
Notes
2017-10-23 14:28:10W. P. B. REVISION: 17090043
 W. P. B. PERMIT: 15111020
 ADD: 1100 S. FLAGLER DR. SUITE: UNIT 9C
 CONT: SUFFOLK
 TEL: 561-691-4552 # 103
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 SUBJECT TO FAIR HOUSING!
  
 2ND REVIEW
 DATE: MON. OCT. 23/2017
  
 ACTION: BUILDING PROVISO
  
 1) SUFFOLK CONSTRUCTION TO CONDUCT SITE TESTING FOR
 COMPLIANCE WITH THE 2010 FBC-B SECTIONS:
 FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FBC-B 2010 1207.2 AIR-BORNE SOUND.
 FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 THESE TESTS WILL BE CONDUCTED ON A 8 INCH CONCRETE SLAB
 UNDER THE MAIN PERMIT (15111020) AND SUBMITTED AS SOON
 AS RESULTS ARE PRINTED AND REVIEWED BY THE DESIGNER OF
 RECORD.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-09-30 Cont ID  
Sent By jwitmer Date 2017-09-30 Time 09:20 Rev Time 0.00
Received By jwitmer Date 2017-09-30 Time 08:30 Sent To  
Notes
2017-09-30 09:20:042014 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 17090043
 W. P. B. PERMIT: 15111020
 ADD: 1100 S. FLAGLER DR. SUITE: UNIT 9-C
 CONT: SUFFOLK
 TEL: 561-407-827-3678 JASON KRAUS
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 SUBJECT TO FAIR HOUSING!
  
 1ST REVIEW
 DATE: SAT. SEPT. 30/2017
 ACTION: DENIED
  
 1A) SHEET 126-15-A2-90-9C SHOWS (2 POCKET DOORS LEADING
 INTO HIS & HERS MASTER BATH THESE DOORS AS SHOWN IN THE
 OPEN POSITION MEASURE 2.50 FT. FAIR HOUSING REQUIRES A
 CLEAR WIDTH OF 32 INCHES. 2014 FBC- ACCESSIBILITY/ FAIR
 HOUSING SECTION 100.205.(C)(2)(2).
  
 1B) MISSING THE HARDWARE PLAN FOR THE POCKET DOORS.
 SHEET 126-15-A2-90-9C SHOWS (2) POCKET DOORS LEADING
 INTO HIS & HER MASTER BATH, PLEASE PROVIDE WHAT TYPE OF
 HANDLES WILL BE INSTALLED ON THE POCKET DOORS, THE
 DOORS CANNOT BE FULLY RECESSED HARDWARE, IT HAS TO BE
 ACCESSIBLE FOR PEOPLE THAT HAVE LIMITED HAND MOBILITY.
 2014 FBC- ACCESSIBILITY/ FAIR HOUSING SECTION
 100.205.(C)(2)(2).FIGURE 1( C ).
  
 1C) PLEASE BE AWARE ALL OF THE EXTERIOR SLIDING GLASS
 DOORS WILL NEED TO MEET THE 32 INCHES CLEAR AND THE
 HARDWARE HAS TO BE ACCESSIBLE FOR PEOPLE THAT HAVE
 LIMITED HAND MOBILITY.
 2014 FBC- ACCESSIBILITY/ FAIR HOUSING SECTION
 100.205.(C)(2)(2).FIGURE 1( C ).
  
  
  
 2A) SHEET 208.19-A6-25-9C FLOOR FINISHES. BLDG TYPE:
 TYPE I/ TYPE II FLOOR INSULATION (FBC-B 2010)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING OR
 PROVIDE TESTING FOR THE THICKNESS FOR THE SLAB AND IF
 THERE IS A DROP CEILING WITH OR WITHOUT INSULATION:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
  
 2A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 2B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-11-06 Cont ID  
Sent By jleahy Date 2017-11-06 Time 08:53 Rev Time 0.00
Received By jleahy Date 2017-11-06 Time 08:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-09-25 Cont ID  
Sent By jleahy Date 2017-09-25 Time 09:27 Rev Time 0.00
Received By jleahy Date 2017-09-25 Time 09:27 Sent To  
Notes
2017-09-25 09:28:12FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PLAN DOSE NOT SHOW CLOUDS FOR REVISION ON PLAN ONLY ON
 THE DRAWING PAGE NUMBER.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-09-15 Cont ID  
Sent By pleduc Date 2017-09-15 Time   Rev Time 0.00
Received By pleduc Date 2017-09-14 Time 16:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-11-06 Cont ID  
Sent By jleahy Date 2017-11-06 Time 08:53 Rev Time 0.00
Received By jleahy Date 2017-10-17 Time 12:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-03 Cont ID  
Sent By lmarchan Date 2017-10-03 Time 11:28 Rev Time 0.00
Received By lmarchan Date 2017-09-06 Time 10:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-11-01 Cont ID  
Sent By ccole Date 2017-11-01 Time 16:32 Rev Time 0.00
Received By ccole Date 2017-11-01 Time 16:24 Sent To  
Notes
2017-11-01 16:33:30MECHANICAL PROVISO:
 PRIOR TO ISSUANCE OF CO, THE DESIGN PROFESSIONAL OF
 RECORD SHALL CERTIFY THE APPLICATION OF THE INTUMESCENT
 PAINT ON THE AC CLOSET DOORS.
 CCOLE- 11/1/2017

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-09-22 Cont ID  
Sent By ccole Date 2017-09-22 Time 17:10 Rev Time 0.00
Received By ccole Date 2017-09-22 Time 17:10 Sent To  
Notes
2017-09-22 17:11:081ST REVIEW FBC-2014 MECHANICAL, WPB AMENDMENTS TO THE
 FBC.
 REVISION #17090043
 MASTER PERMIT #15111020
 THE BRISTOL
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE AC CLOSET DOORS UO5K & UO5Q MUST BE
 NON-COMBUSTIBLE- SECTION 602.2.1. THE DOOR SCHEDULE ON
 THE MASTER SHEET A8.12 INDICATES WOOD DOORS.
  
 2) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN FOR THE
 COOKING APPLIANCE IN THE KITCHEN AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS WITH APPROVAL STAMP AND
 SIGNATURE BY THE EOR- SECTION 623.1- 623.5 FBC-14 FUEL
 GAS.
  
 3) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN FOR THE
 EXHAUST VENTILATION HOOD AND EXHAUST DUCT, AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS WITH APPROVAL STAMP AND
 SIGNATURE BY THE EOR- SECTIONS 505.1 AND 505.2.
  
 4) SHEET M2.90-9C: PLEASE LABEL THE ROOMS ON THE
 REVISED PLAN.
  
 5) SHOW THE LOCATIONS OF THE RETURN OPENINGS AT THE
 PERIMETER COVES AND PROVIDE A DETAIL. PLEASE NOTE THAT
 ALL AIR SUPPLIED TO A MASTER SUITE MUST BE RETURNED-
 SECTION 601.5 (3).
  
 6) PROVIDE SUBDUCT INSTALLATION DETAILS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-10-03 Cont ID  
Sent By gjohnson Date 2017-10-03 Time 11:07 Rev Time 0.00
Received By gjohnson Date 2017-10-03 Time 11:07 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-09-26 Cont ID  
Sent By jroach Date 2017-09-26 Time 09:05 Rev Time 0.00
Received By jroach Date 2017-09-26 Time 09:05 Sent To  
Notes
***NONE***