| Plan Review Stops For Permit 17090022 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2018-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-01-24 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-01-24 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2017-11-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-11-30 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-11-30 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2017-11-30 08:24:18 | THE PERMIT CAN NOT BE ISSUED UNTIL AN ADDRESS HAS BEEN | | | ASSIGNED TO THE PROPERTY. IN ORDER TO OBTAIN AN | | | ADDRESS, PLEASE CONTACT MICHEAL ORIO BY PHONE AT | | | 561-494-1080 OR BY EMAIL AT [email protected]. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-02-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-02-15 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-02-14 |
Time |
18:42 |
Sent To |
I |
|
| Notes |
| 2018-02-15 13:45:04 | APPROVED WITH EXCEPTIONS | | | "PROVISO" | | | | | | 1) SUBMIT TWO SETS OF MANUFACTURER'S SPECIFICATIONS AND | | | ATTACHMENT DETAILS FOR THE PROPOSED "DECORATIVE" BAHAMA | | | SHUTTERS FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-01-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-01-26 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-01-24 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2018-01-26 13:49:38 | PLAN | | | REVIEW COMMENTS | | | | | | 3RD REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES. PROVIDE PRODUCT APPROVALS | | | FOR THE BAHAMA SHUTTERS AND THE HORIZONTAL SLIDING | | | WINDOW (BEDROOM #4). | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-11-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-11-30 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-11-30 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2017-11-30 17:25:41 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | NOTE: A RECORDED PLAT, A PROPERTY CONTROL NUMBER AND A | | | STREET ADDRESS WILL BE REQUIRED BEFORE A BUILDING | | | PERMIT WILL BE ISSUED. | | | | | | 1) (PREVIOUS COMMENT) FBC 107.3.4 - PROVIDE TWO SETS OF | | | PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE | | | REGULATED BY FAC 61G20-3.001 PER FLORIDA STATUTE | | | 553.842 (5) THAT HAVE BEEN REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD. PROVIDE TWO COMPLETE | | | PRODUCT APPROVALS WITH FL OR NOA NUMBERS INCLUDING | | | INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES. | | | PROVIDE PRODUCT APPROVALS FOR THE SELF-ADHERED ROOFING | | | MATERIAL, AND THE BAHAMA SHUTTERS. | | | | | | 2) (PREVIOUS COMMENT) SPECIFY THE METHOD OF ATTACHMENT | | | THAT WILL BE USED TO INSTALL THE CONCRETE ROOF TILE. IF | | | AN ADHESIVE WILL BE USED, SUBMIT TWO SETS OF THE | | | PRODUCT APPROVALS FOR IT. FBC-R905.3.7 & FBC 107.3.4 | | | | | | 3) A PRODUCT APPROVAL FOR A METAL ROOF WAS SUBMITTED | | | AND THE ROOF NOTES ON SHEET A-1.4.01A AND A-1.4.02A | | | REFER TO A METAL ROOF. DO YOU INTEND TO OFFER THE METAL | | | ROOF AS AN OPTION TO THE CEMENT TILE ROOF ? IF THAT IS | | | THE CASE, PLEASE INDICATE THIS ON THE PLANS. ALSO, | | | PROVIDE PRODUCT APPROVALS FOR THE UPPER ROOF VENTS THAT | | | CAN BE USED WITH THE METAL ROOF. FBC 107.2.1 AND FBC | | | 107.3.4 | | | | | | 4) (PREVIOUS COMMENT) SHOW COMPLIANCE WITH FBC-R302.12 | | | DRAFTSTOPPING. IN COMBUSTIBLE CONSTRUCTION WHERE THERE | | | IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED | | | SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE | | | INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES | | | NOT EXCEED 1,000 SQUARE FEET (92.9 M2). DRAFTSTOPPING | | | SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY | | | EQUAL AREAS. WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR | | | MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW, | | | DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING | | | ASSEMBLIES UNDER THE FOLLOWING CIRCUMSTANCES: | | | 1. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING. | | | 2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYPE OPEN-WEB | | | OR PERFORATED MEMBERS. | | | | | | 13) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-09-25 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-09-19 |
Time |
06:46 |
Sent To |
|
|
| Notes |
| 2017-09-19 17:42:55 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | NOTE: A RECORDED PLAT, A PROPERTY CONTROL NUMBER AND A | | | STREET ADDRESS WILL BE REQUIRED BEFORE A BUILDING | | | PERMIT WILL BE ISSUED. | | | | | | 1) THE BUCK FASTENING REQUIREMENTS ARE NOT PROVIDED IN | | | THE WINDOW, SLIDING GLASS DOOR AND OUTSWING DOOR | | | PRODUCT APPROVALS. THE DESIGNER OF RECORD IS REQUIRED | | | TO SPECIFY THE TYPE OF FASTENER AND SPACING FOR THE | | | BUCKS ON THE PLANS. FBC-R612 | | | | | | 2) ON SHEET S-0.00 UNDER WOOD, IT SHOULD BE NOTED THAT | | | 8D RINK SHANK NAILS ARE REQUIRED. FBC-R 803.2.3.1 | | | | | | 3) THE BEAM IN THE GARAGE ON SHEET S-2.01A HAS AN ID | | | TAG TS-3, HOWEVER, THERE IS NO TS-3 LISTED IN THE | | | SCHEDULE ON SHEET S-4.00A. FBC 107.2.1 | | | | | | 4) ON SHEET S-2.02A THE TRUSS ANCHORS FOR THE LOWER | | | ROOF AT THE GARAGE AREA ARE NOT SPECIFIED ON THE PLANS. | | | FBC 107.2.1 | | | | | | 5) ON SHEET S-203 THE TRUSS ANCHOR FOR THE GIRDER TRUSS | | | AT THE LOWER RIGHT SIDE OF THE DRAWING IS NOT | | | SPECIFIED. FBC 107.2.1 | | | | | | 6) ON SHEET S-203 THERE IS A TYPO AT THE LOWER RIGHT | | | SIDE OF THE DRAWING THAT SHOWS TWO EXTERIOR WALLS. FBC | | | 107.2.1 | | | | | | 7) SPECIFY THE FASTENERS THAT ARE REQUIRED FOR THE | | | SIMPSON HU 410 HANGER DETAIL 12/S-3.00 AT THE MASONRY | | | WALL AND SPECIFY THE CONNECTOR THAT WILL BE USED AT THE | | | WOOD FRAME WALL. FBC 107.2.1 | | | | | | 8) INDICATE THE CONNECTORS THAT WILL BE USED TO ATTACH | | | THE WOOD FLOOR TRUSSES TO THE WOOD LEDGERS TO RESIST | | | LATERAL FORCES ON THE EXTERIOR WALLS. FBC 301.1 | | | | | | 9) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES. PROVIDE PRODUCT APPROVALS | | | FOR THE SELF-ADHERED ROOFING MATERIAL, THE BAHAMA | | | SHUTTERS AND FOR THE 16' WIDE SECTIONAL GARAGE DOOR ( | | | THE ONE THAT WAS SUBMITTED IS FOR A MAXIMUM 9' WIDE | | | GARAGE DOOR). | | | | | | 10) SUBMIT A CURRENT PRODUCT APPROVAL FOR THE FIXED | | | WINDOW. NOA NO. 14-0908.18, EXPIRED PRIOR THE PERMIT | | | APPLICATION DATE. FBC 107.3.4 | | | | | | 11) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED | | | TO INSTALL THE CONCRETE ROOF TILE. IF AN ADHESIVE WILL | | | BE USED, SUBMIT TWO SETS OF THE PRODUCT APPROVALS FOR | | | IT. FBC-R905.3.7 & FBC 107.3.4 | | | | | | 12) SHOW COMPLIANCE WITH FBC-R302.12 DRAFTSTOPPING. IN | | | COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE | | | BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A | | | FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED | | | SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED | | | 1,000 SQUARE FEET (92.9 M2). DRAFTSTOPPING SHALL DIVIDE | | | THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. | | | WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE | | | ABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPING SHALL | | | BE PROVIDED IN FLOOR/CEILING ASSEMBLIES UNDER THE | | | FOLLOWING CIRCUMSTANCES: | | | 1. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING. | | | 2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYPE OPEN-WEB | | | OR PERFORATED MEMBERS. | | | | | | 13) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-01-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-01-17 |
Time |
07:08 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-01-17 |
Time |
07:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-11-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-27 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-27 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2017-11-27 11:24:54 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | 2ND ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS | | | BELOW. | | | | | | PREVIOUS COMMENTS CORRECTED ARE NOTED AS CORRECTED. | | | REMAINING ITEMS HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. | | | | | | 1. PROVIDE COMPLETED PANEL SCHEDULE. CURRENTLY, PANEL | | | SCHEDULE DOES NOT SHOW ANY LOADS FOR EACH CIRCUIT, DOES | | | NOT SHOW WIRE SIZE, AND DOES NOT INDICATE AFCI OR GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8, 210.12, | | | 215.5, 408.4; FBC RE3706.2, RE3902; FBC 107.2.1 | | | (CURRENTLY, THE PANEL IS SHOWN AS OVERLOADED BECAUSE | | | THE DEMAND FACTORS ARE NOT APPLIED. ANY LOAD THAT IS | | | FIGURED IN THE GENERAL LIGHTING LOAD DOES NOT NEED TO | | | BE LISTED IN THE SCHEDULE. AN ASTERISK IS ACCEPTABLE | | | THAT EXPLAINS THE LOAD IS INCLUDED IN GENERAL LIGHTING | | | LOAD.) | | | 2. CORRECTED. | | | 3. SERVICE DISCONNECT ON POWER PLAN IS SHOWN AS | | | NON-FUSED. OVERCURRENT PROTECTION IS REQUIRED AT THIS | | | LOCATION. PROVIDE CORRECTION. NEC 230.91; FBC RE | | | 3603.3.3 (THE CURRENT LOAD CALCULATION IS CALLING FOR A | | | 250 AMP PANEL, BUT THE CORRECTION SUPPLIED SHOWS 200 | | | AMP FUSES IN A 200 AMP DISCONNECT, WHICH WOULD BE TOO | | | SMALL FOR THE LOAD. ALTHOUGH, THIS MAY CHANGE DEPENDING | | | ON THE ACTUAL WATER HEATER LOAD, SEE COMMENT BELOW FOR | | | WATER HEATER. IF AFTER CORRECTIONS, THE 200 AMP IS | | | ENOUGH TO HANDLE THE LOAD, THEN NO CORRECTION IS | | | REQUIRED.) | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. CORRECTED. | | | 12. THE WATER HEATER SPECIFIED ON SHEET P.0.0.00 IS | | | SHOWN WITH 4500 WATT ELEMENTS. THE PANEL SCHEDULE SHOWS | | | A 35 AMP BREAKER FOR THIS UNIT, WHICH IS TOO LARGE PER | | | CODE. BREAKER SHOULD BE SIZED AT 125% OF THE LOAD, | | | WHICH WOULD BE A 25 AMP BREAKER. PROVIDE CORRECTION. | | | NEC 422.13; FBC RE3702.10 (THE CORRECTION SUPPLIED IS | | | THE CORRECT BREAKER SIZE FOR 4500 WATT ELEMENTS, BUT | | | NOW THE PLUMBING SHEET SHOWS A DIFFERENT AMOUNT FOR THE | | | WATER HEATER, WHICH ALSO DOESN'T AGREE WITH THE AMOUNT | | | IN THE LOAD CALCULATION. I SEE FROM THE SPECS THAT THIS | | | WATER HEATER CAN BE WIRED FOR SIMULTANEOUS OR | | | NON-SIMULTANEOUS OPERATION. FURTHER CLARIFICATION IS | | | NEEDED TO DETERMINE THE PROPER WIRING AND OCP REQUIRED, | | | WHICH ALSO MAY CHANGE THE TOTAL LOAD CALCULATION. FEEL | | | FREE TO CALL OR EMAIL ME AND DISCUSS IF DESIRED.) | | | 13. CORRECTED. | | | 14. CORRECTED. | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-09-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-14 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-14 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2017-09-14 16:09:06 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE COMPLETED PANEL SCHEDULE. CURRENTLY, PANEL | | | SCHEDULE DOES NOT SHOW ANY LOADS FOR EACH CIRCUIT, DOES | | | NOT SHOW WIRE SIZE, AND DOES NOT INDICATE AFCI OR GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8, 210.12, | | | 215.5, 408.4; FBC RE3706.2, RE3902; FBC 107.2.1 | | | 2. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. NEC 250.94; FBC RE3609.3 | | | 3. SERVICE DISCONNECT ON POWER PLAN IS SHOWN AS | | | NON-FUSED. OVERCURRENT PROTECTION IS REQUIRED AT THIS | | | LOCATION. PROVIDE CORRECTION. NEC 230.91; FBC RE | | | 3603.3.3 | | | 4. NOTE 6 STATES "PROVIDE ARC FAULT RECEPTACLES AS PER | | | NEC 210.12". CODE REQUIRES THE FOLLOWING: "ALL | | | 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH | | | CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, | | | HALLWAYS, OR SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI | | | PROTECTION". PROVIDE CORRECTION TO INCLUDE MORE THAN | | | RECEPTACLES. NEC 210.12; FBC RE3902.12 | | | 5. DUE TO THE TYPE OF LIGHT FIXTURES NOT CLARIFIED IN | | | CLOSETS, PROVIDE NOTE THAT LIGHT FIXTURES SHALL COMPLY | | | WITH NEC 410.16. NEC 410.16; FBC RE4003.12 | | | 6. DUE TO THE TYPE OF LIGHT FIXTURES NOT CLARIFIED IN | | | DAMP LOCATIONS, PROVIDE NOTE THAT LIGHT FIXTURES SHALL | | | COMPLY WITH NEC 410.10. NEC 410.10(D); FBC RE4003.11 | | | 7. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC CE R404.1 | | | 8. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE4002.14 | | | 9. PROVIDE A BLOCK NOTE INDICATING THE REQUIRED | | | SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS WHERE APPLICABLE FOR LOW VOLTAGE SYSTEMS, | | | FIRE ALARM, CCTV, PHONE AND DATA, WIRELESS SYSTEMS, | | | WALK-IN COOLERS, HOODS, ETC. FBC 105.1, 107.2.1 | | | 10. THE COVERED PATIO SHOWS 2 GFCI STANDARD OUTLETS IN | | | SUMMER KITCHEN. THESE OUTLETS ARE REQUIRED TO BE | | | WEATHER PROOF. PROVIDE CORRECTION. NEC 406.9; FBC RE | | | 4002.8 | | | 11. CODE STATES: "FOR DWELLING UNITS, ATTACHED GARAGES, | | | AND DETACHED GARAGES WITH ELECTRIC POWER, AT LEAST ONE | | | WALL SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE | | | INSTALLED ON THE EXTERIOR SIDE OF OUTDOOR | | | ENTRANCES/EXITS WITH GRADE LEVEL ACCESS". SOME OF THE | | | ENTRY/EXITS DO NOT SHOW A SWITCH TO OUTSIDE LIGHTS. | | | PROVIDE CORRECTION. NEC 210.70(A)(2)(B), FBC RE3903.3 | | | 12. THE WATER HEATER SPECIFIED ON SHEET P.0.0.00 IS | | | SHOWN WITH 4500 WATT ELEMENTS. THE PANEL SCHEDULE SHOWS | | | A 35 AMP BREAKER FOR THIS UNIT, WHICH IS TOO LARGE PER | | | CODE. BREAKER SHOULD BE SIZED AT 125% OF THE LOAD, | | | WHICH WOULD BE A 25 AMP BREAKER. PROVIDE CORRECTION. | | | NEC 422.13; FBC RE3702.10 | | | 13. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC R314.3, R315.1; FBC 107.2.1 | | | 14. RECEPTACLES FOR GARAGE DOOR OPENERS, CIRCUITS D2-34 | | | AND D2-35, REQUIRE GFCI PROTECTION. PROVIDE CORRECTION. | | | NEC 210.8; FBC RE3902.2 | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2020-05-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-01 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-01 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-25 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-25 |
Time |
18:12 |
Sent To |
|
|
| Notes |
| 2017-09-25 18:13:06 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | | | | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-02-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-02-15 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-02-05 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2018-02-07 10:10:51 | RESUB ROUTED TO HMOSER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-02-02 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-01-10 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-12-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-12-14 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-11-13 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-25 |
Time |
19:10 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-01 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-01-24 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-01-24 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2018-01-24 13:15:15 | MU-2018-455, PAID $9780.28 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-09-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-09-18 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-09-18 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2017-09-18 10:43:07 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2018-02-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-02-12 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-02-12 |
Time |
14:03 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-01-29 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-01-29 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2018-01-29 11:35:44 | PLAN DENIED | | | NO DUCT WORK SHOWN ON 2ED FLOOR MECHANICAL | | | PLAN. PER SECTION 107 FBC 2014 | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-11-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-11-29 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-11-29 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2017-11-29 11:45:36 | PLAN DENIED | | | NO SECOND FLOOR AIR CONDITIONING PLAN SUBMITTED WITH | | | PLAN. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-09-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-09-19 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-09-19 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2017-09-19 10:24:17 | PASS PROVISO | | | REFER TO SECTION M1503.4 MAKEUP AIR | | | 2014 RESIDENTIAL CODE. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-01-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-24 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-24 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-11-28 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-11-28 |
Time |
05:49 |
Sent To |
|
|
| Notes |
| 2017-11-28 13:53:57 | 1) THE WATER HEATER IN THE GARAGE SHALL BE PROTECTED | | | FROM PHYSICAL DAMAGE. SUBMIT DETAILS AS TO HOW THIS | | | WILL BE ACCOMPLISHED. | | | 2) PROVIDE THE SHOWER DIMENSIONS FOR THE SHOWER (L X W) | | | IN BATHROOM #4. COMPLY WITH FBCR SEC. P2708.1. | | | 3) SHT. A - 4.202 - DETAIL #8 SHOWS THE SHOWER TO BE | | | PITCHED AT 1% SLOPE. SEC. P2709.1 OF 2014 FBCR REQUIRES | | | THE SHOWER TO BE PITCHED 1/4 INCH PER FOOT (2 %) TO THE | | | DRAIN. | | | 4) SHT. P.1.3.00 - NOTE #2 - THE DISCHARGE OF THE T & P | | | VALVE ON THE WATER HEATER SHALL DISCHARGE THROUGH AN | | | AIR GAP IN THE SAME ROOM AS THE WATER HEATER. 2014 FBCR | | | SEC. P2803.6.1. | | | 5) THE BACK TO BACK BATHTUBS IN BATHROMMS # 2 & #3 ON | | | THE 2ND FLOOR ARE NOT VENTED. 2014 FBCR SEC. P3101.2, | | | P3101.2.1. | | | 6) PROVISIONS SHALL BE MADE FOR THERMAL EXXPANSION.2014 | | | FBCR SEC.P2903.4. | | | 7) SHOW THE FIXTURE CLEARANCES FOR THE FIXTURES PER | | | 2014 FBCR SEC.P2705.1. | | | 8) SHT. P.1.4.00 - NOTE #4 - STATES 3/4 INCH HOT AND | | | COLD UP TO THE 2ND FLOOR BUT THE PLAN SHOWS 1/2 INCH | | | HOT WATER AND SHT P.3.00 SHOWS 1/2 INCH HOT WATER TO | | | THE 2ND FLOOR. CLARIFY. THERE ARE THE SAME | | | DISCREPANCIES ON THE PLANS FOR OTHER LOCATIONS TO THE | | | SECOND FLOOR. THE WATER RISER SIZES ON THE FLOOR PLAN, | | | THE NOTES AND THE WATER ISOMETRIC SHALL CORRELATE. WPB | | | AMEND. TO FBC SEC. 107.2.1.ALSO SEE SHT. # P.1.4.0.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-25 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-25 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2017-09-25 19:10:12 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. P.3.0.01 + P.3.0.00 LABEL ALL FIXTURES ON THE | | | ISOMETRIC DRAWINGS. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. SHT. P.3.0.01 + P.3.0.00 SIZE ALL PIPING ON THE | | | ISOMETRIC DRAWINGS. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. SHT. P.3.0.01 THE VENT CONNECTIONS ARE NOT SHOWN ON | | | THE SANITARY ISOMETRIC DRAWING. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 4. SHT. P.3.0.01SHOW PTRAPS ON THE SHOWERS AND TUBS ON | | | THE SANITARY ISOMETRIC DRAWING. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 5. A CLEANOUT SHALL BE PROVIDED AT THE BASE OF EACH | | | WASTE OR SOIL STACK. PER FBC RES P3005.2.6 | | | | | | 6. THERE SHALL BE A CLEANOUT NEAR THE JUNCTION OF THE | | | BUILDING DRAIN AND BUILDING SEWER. PER FBC RES | | | P3005.2.7 | | | | | | 7. SUMMER KITCHEN NOT SHOWN ON SANITARY ISOMETRIC. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 8. SHT. P4.0.00 DETAIL #1 SHOWS FLOOR DRAIN/ HUBDRAIN | | | NOT SHOWN ON SANITARY ISOMETRIC PLEASE CLARIFY. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 9. PLEASE PROVIDE A KEY FOR THE ABBREVIATIONS ON THE | | | WATER ISOMETRIC DRAWING. PER WPB AMEND TO FBC 107.2.1 | | | | | | 10. HOT WATER SUPPLIED TO BATHTUBS AND WHIRLPOOL | | | BATHTUBS SHALL BE LIMITED TO A TEMPERATURE OF NOT | | | GREATER THAN 120?F (49?C) BY A WATERTEMPERATURE | | | LIMITING DEVICE THAT CONFORMS TO ASSE 1070 OR CSA | | | B125.3. PER FBC RES P2713.3 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2018-02-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-02-15 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-02-15 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2018-02-15 15:09:07 | ENTEGRA PLANTATION ROOF TILE - NOA NO. 15-0721.04 | | | O'HAGIN'S CLOAKED VENT TILE - NOA NO. 13-0122.07 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-02-02 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-02-02 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2018-02-02 11:09:57 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 02.02.2018 | | | PERMIT NO.: 17090022 | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, | | | ALL LANDSCAPING FOR THE SUBJECT RESIDENCE SHALL BE | | | INSTALLED IN ACCORDANCE WITH APPROVED PLANS (PERMIT | | | #17110878) AND PASS INSPECTION. | | | | | | 2. PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF | | | OCCUPANCY WITHIN THE DEVELOPMENT, ALL COMMON AREA | | | ELEMENTS (INCLUDING SIDEWALKS, LANDSCAPING, ENTRY, | | | STREETSCAPE, CONGRESS AVENUE BUFFER, ETC.) SHALL BE | | | INSTALLED (IN ACCORDANCE WITH APPROVED/PERMITTED PLANS. | | | | | | 3. PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF | | | OCCUPANCY WITHIN THE DEVELOPMENT, THE FOUNTAINS | | | REQUIRED BY THE DESIGN GUIDELINES SHALL BE INSTALLED IN | | | ALL LAKE AREAS THAT SEPARATE THE DEVELOPMENT FROM THE | | | EXISTING RESIDENTIAL NEIGHBORHOODS. | | | | | | 4. THE USE OF THE STRUCTURE AS A MODEL DWELLING SHALL | | | NOT EXCEED TWO (2) YEARS (FROM THE DATE OF ISSUANCE OF | | | THE CO), UNLESS AN EXTENSION HAS BEEN GRANTED BY THE | | | PLANNING & ZONING ADMINISTRATOR. | | | | | | 5. THE MODEL DWELLING SHALL BE NOT BE USED TO PROMOTE | | | THE SALE OF LOTS OR DWELLINGS NOT LOCATED IN THE | | | PROJECT. | | | | | | 6. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, | | | AT LEAST FIVE (5) OFF-STREET PARKING SPACES SHALL BE | | | PROVIDED. | | | | | | 7. THE MODEL DWELLING SHALL NOT BE ILLUMINATED (EXCEPT | | | AS IS CUSTOMARY FOR A RESIDENTIAL DWELLING) OR USED FOR | | | ANY BUSINESS ACTIVITY LATER THAN 9:00PM. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | E: [email protected] | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2017-12-14 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-12-14 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-12-14 |
Time |
14:55 |
Sent To |
PC |
|
| Notes |
| 2017-12-14 15:06:09 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 12.14.2017 | | | PERMIT NO.: 17090022 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PRIOR TO THE ISSUANCE OF ANY PERMITS FOR THE SINGLE | | | FAMILY DEVELOPMENT WITHIN BANYAN CAY, A MINOR PLANNED | | | DEVELOPMENT AMENDMENT SHALL BE SUBMITTED TO THE | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION, | | | AND APPROVED. THE MINOR AMENDMENT SHOULD PROVIDE FOR | | | ALL OF THE MODELS THAT ARE PROPOSED, AND SHOW | | | COMPLIANCE WITH THE BANYAN CAY DESIGN GUIDELINES, | | | INCLUDING COLOR SCHEMES, THE MINIMUM NUMBER OF EXTERIOR | | | MODIFICATIONS THAT ARE REQUIRED, AND THE MINIMUM NUMBER | | | OF UNIT LANDSCAPE PLANS. | | | | | | 6. PLEASE NOTE THAT PRIOR TO THE ISSUANCE OF THE FIRST | | | CERTIFICATE OF OCCUPANCY, ALL COMMON AREA LANDSCAPING | | | SHALL BE INSTALLED (ENTRY, STREETSCAPE, CONGRESS AVENUE | | | BUFFER, ETC.). | | | | | | 7. PLEASE NOTE THAT PRIOR TO THE ISSUANCE OF THE FIRST | | | CERTIFICATE OF OCCUPANCY, THE FOUNTAINS REQUIRED BY THE | | | DESIGN GUIDELINES SHALL BE INSTALLED IN ALL LAKE AREAS | | | THAT SEPARATE THE DEVELOPMENT FROM THE EXISTING | | | RESIDENTIAL NEIGHBORHOODS. | | | | | | 8. ACCORDING TO THE APPROVED CROSS SECTION FOR THE 40 | | | FOOT WIDE PRIVATE ROADWAY, AS APPROVED IN THE DESIGN | | | GUIDELINES, THERE IS TO BE A 4 FOOT MEANDERING SIDEWALK | | | ALONG THE STREET THAT MEANDERS FROM THE RIGHT-OF-WAY | | | INTO THE SIDEWALK EASEMENT, BACK INTO THE RIGHT-OF-WAY, | | | ETC. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
JROACH |
Date |
2017-09-25 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-09-25 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2017-09-25 16:22:54 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 09.25.2017 | | | PERMIT NO.: 17090022 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PRIOR TO THE ISSUANCE OF ANY PERMITS FOR THE SINGLE | | | FAMILY DEVELOPMENT WITHIN BANYAN CAY, A MINOR PLANNED | | | DEVELOPMENT AMENDMENT SHALL BE SUBMITTED TO THE | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION, | | | AND APPROVED. THE MINOR AMENDMENT SHOULD PROVIDE FOR | | | ALL OF THE MODELS THAT ARE PROPOSED, AND SHOW | | | COMPLIANCE WITH THE BANYAN CAY DESIGN GUIDELINES, | | | INCLUDING COLOR SCHEMES, THE MINIMUM NUMBER OF EXTERIOR | | | MODIFICATIONS THAT ARE REQUIRED, AND THE MINIMUM NUMBER | | | OF UNIT LANDSCAPE PLANS. | | | | | | 2. PRIOR TO THE ISSUANCE OF ANY PERMITS FOR THE SINGLE | | | FAMILY DEVELOPMENT WITHIN BANYAN CAY, THE PLAT SHALL BE | | | RECORDED TO ESTABLISH THE INDIVIDUAL FEE-SIMPLE LOTS. | | | WHILE THE PLAT WAS PREVIOUSLY APPROVED, IT IS REQUIRED | | | THAT A MINOR SUBDIVISION APPLICATION BE SUBMITTED TO | | | THE DEVELOPMETN SERVICES DEPARTMENT ? PLANNING DIVISION | | | AND BE APPROVED BY THE CITY COMMISSION, AS THE NAME OF | | | THE PLAT HAS CHANGED, THE LOCATIONS OF THE EASEMENTS | | | HAS CHANGED, ETC. | | | | | | 3. THE DIMENSIONS OF THE PROPOSED SITE SETBACKS ON THE | | | SITE PLAN DIFFER FROM THAT WHICH IS SHOWN ON THE | | | SURVEY. ENSURE THAT ALL PLANS ARE CONSISTENT AND | | | ACCURATE. | | | | | | 4. THE SITE PLAN SHOULD IDENTIFY THE LOCATION OF ANY | | | PROPOSED MECHANCIAL EQUIPMENT (I.E. A/C CONDENSING | | | UNITS). PLEASE NOTE THAT MECHANICAL EQUIPMENT MAY NOT | | | ENCROACH MORE THAN FOUR (4) FEET INTO ANY REQUIRED | | | PRINCIPAL STRUCTURE SETBACK. | | | | | | 5. ALL LANDSCAPING SHALL BE SUBMITTED AND APPROVED AS A | | | SEPARATE LANDSCAPE PERMIT. | | | | | | 6. PLEASE NOTE THAT PRIOR TO THE ISSUANCE OF THE FIRST | | | CERTIFICATE OF OCCUPANCY, ALL COMMON AREA LANDSCAPING | | | SHALL BE INSTALLED (ENTRY, STREETSCAPE, CONGRESS AVENUE | | | BUFFER, ETC.). | | | | | | 7. PLEASE NOTE THAT PRIOR TO THE ISSUANCE OF THE FIRST | | | CERTIFICATE OF OCCUPANCY, THE FOUNTAINS REQUIRED BY THE | | | DESIGN GUIDELINES SHALL BE INSTALLED IN ALL LAKE AREAS | | | THAT SEPARATE THE DEVELOPMENT FROM THE EXISTING | | | RESIDENTIAL NEIGHBORHOODS. | | | | | | 8. ACCORDING TO THE APPROVED CROSS SECTION FOR THE 40 | | | FOOT WIDE PRIVATE ROADWAY, AS APPROVED IN THE DESIGN | | | GUIDELINES, THERE IS TO BE A 4 FOOT MEANDERING SIDEWALK | | | ALONG THE STREET THAT MEANDERS FROM THE RIGHT-OF-WAY | | | INTO THE SIDEWALK EASEMENT, BACK INTO THE RIGHT-OF-WAY, | | | ETC. | | | | | | 9. LANDSCAPE PLANS NEED TO SHOW THE PROPERTY | | | BOUNDARIES. | | | | | | 10. LANDSCAPE PLANS SHALL PROVIDE A TABLE SHOWING | | | COMPLIANCE WITH SECTION 94-442(B)(2)A. OF THE CITY?S | | | ZONING AND LAND DEVELOPMENT REGULATIONS (REQUIRED | | | AMOUNT OF PLANT MATERIAL). | | | | | | 11. IT APPEARS ON THE LANDSCAPE PLAN THAT THE A LARGE | | | SHAD TREE IS PROPOSED TO BE INSTALLED IN THE UTILTY | | | EASEMENT. PLANTING IN AN EASEMENT SHALL REQUIRE THE | | | CONSENT OF ALL EASEMENT HOLDERS. | | | | | | 12. IT APPEARS THAT THE PROPOSED LANDSCAPE PLAN HAS NOT | | | ACCOUNTED FOR THE APPROVED STREETSCAPE PLAN. PLEASE | | | ENSURE THAT ALL PLANS ARE COMPATIBLE AND ARE SHOWN IN | | | CONTEXT WITH ONE ANOTHER. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|