Plan Review Details - Permit 17090021
| Plan Review Stops For Permit 17090021 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-02-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-02-27 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-02-27 |
Time |
07:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-01-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-01-31 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-01-31 |
Time |
12:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-11-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-11-20 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-11-20 |
Time |
07:25 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-09-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-09-20 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-09-19 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2017-09-20 10:24:53 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTE: THIS IS A SFR UNIT BEING USED AS A SALES CENTER. | | | BUILDING OFFICIAL CHANGED OCCUPANCY CLASSIFICATION FROM | | | RESIDENTIAL TO BUSINESS. | | | THIS REVIEW IS BASED ON THE 2014 FLORIDA BUILDING CODE | | | AND THE 2014 FLORIDA ACCESSIBILITY CODE. | | | PLEASE REMOVE ALL REFERENCES TO THE 2014 FLORIDA | | | RESIDENTIAL CODE FROM PLANS. | | | PLEASE NOTE ANY RESIDENTIAL FEATURE ON PLANS AS FUTURE | | | USE. | | | | | | 1. PROVIDE ADDRESS AND RECORDED PLATT. | | | 2. PROVIDE SITE PLAN - SHOW ACCESSIBLE PARKING AND | | | ACCESSIBLE ROUTE. | | | 3. VALUE - BASED ON THE INTERNATIONAL CODE COUNCIL | | | BUILDING VALUATION DATA, THE VALUE WILL BE INCREASED | | | FROM $139,160.00 TO $270,745.00 BASED ON 2,331 SQ. FT. | | | UNDER AIR X $116.15/SQ. FT. | | | 4. ENERGY SUBMITTAL NEEDS TO BE SITE SPECIFIC. PROVIDE | | | ADDRESS. | | | 5. NOA 14-0908.18 FOR THE FIXED WINDOWS HAS EXPIRED. | | | PROVIDE CURRENT NOA. | | | 6. ADA POWDER ROOM TURNING RADIUS DOES NOT COMPLY WITH | | | ACCESSIBILITY CODE 304.3.1, 603.2.1 & 603.2.3. | | | 7. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR | | | SUMMER KITCHEN BBQ. | | | 8. NO KITCHEN IS SHOWN ON ARCHITECTURAL DRAWINGS. | | | IDENTIFY KITCHEN ON MEP PLANS AS FUTURE USE. | | | 9. PROVIDE DOOR BUCK DETAIL FOR OHD, SGD & EXT. DOORS. | | | 10. REVISE PLANS TO INDICATE GOVERNING CODES AS 2014 | | | FBC. RESIDENTIAL CODE DOES NOT APPLY. IDENTIFY | | | RESIDENTIAL ELEMENTS ON PLANS AS FUTURE USE. | | | | | | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING | | | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA | | | AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION | | | PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL | | | FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING | | | DIMENSIONS; AND ALL EXTERIOR ELEVATIONS: | | | | | | CITY OF WPB CHPT. 1 - VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR | | | SUBMITTALS. | | | | | | 304.3.1 CIRCULAR SPACE. | | | THE TURNING SPACE SHALL BE A SPACE OF 60 INCHES (1525 | | | MM) DIAMETER MINIMUM. THE SPACE SHALL BE PERMITTED TO | | | INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH 306 | | | 603.2.1 TURNING SPACE. | | | TURNING SPACE COMPLYING WITH 304 SHALL BE PROVIDED | | | WITHIN THE ROOM. | | | 603.2.2 OVERLAP. | | | REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES, AND | | | TURNING SPACE SHALL BE PERMITTED TO OVERLAP. | | | 603.2.3 DOOR SWING. | | | DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR | | | CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE | | | PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-01-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-01-17 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-01-17 |
Time |
08:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-11-12 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-12 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-12 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2017-11-12 11:12:35 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: 2ND REVIEW, ITEMS CORRECTED | | | ARE NOTED. REMAINING ITEMS NEED FURTHER CORRECTION, SEE | | | ADDITIONAL NOTES IN PARENTHESES. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. SERVICE DISCONNECT ON POWER PLAN IS SHOWN AS | | | NON-FUSED. OVERCURRENT PROTECTION IS REQUIRED AT THIS | | | LOCATION. PROVIDE CORRECTION. NEC 230.91; FBC RE | | | 3603.3.3 (THERE IS A CONFLICT BETWEEN WHAT IS STATED ON | | | POWER PLAN AS 200 AMP FUSES AND THE "UNIT LOAD | | | ANALYSIS" WHICH SHOWS A 175 AMP SERVICE WITH 1/0 WIRE. | | | 1/0 WIRE IS FINE FOR 175 AMP SERVICE, BUT NOT FOR 200 | | | AMP SERVICE. CLARIFY AND/OR CORRECT.) | | | 4. CORRECTED. | | | 5.CORRECTED. | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8.CORRECTED. | | | 9.CORRECTED. | | | 10. CORRECTED. | | | 11. THE WATER HEATER SPECIFIED ON SHEET P.0.0.00 IS | | | SHOWN WITH 4500 WATT ELEMENTS. THE PANEL SCHEDULE SHOWS | | | A 35 AMP BREAKER FOR THIS UNIT, WHICH IS TOO LARGE PER | | | CODE. BREAKER SHOULD BE SIZED AT 125% OF THE LOAD, | | | WHICH WOULD BE A 25 AMP BREAKER. PROVIDE CORRECTION. | | | NEC 422.13; FBC RE3702.10 (WATER HEATER IS NOW SHOWN AS | | | 6.1 KW, WHICH WOULD REQUIRE A 35 AMP BREAKER, BUT PANEL | | | SCHEDULE CALLS FOR A 70 AMP BREAKER. PROVIDE | | | CORRECTION.) | | | 12. CORRECTED. | | | 13. CORRECTED. | | | 15. CONDENSING UNIT IS SHOWN BEING FED FROM A 30 AMP | | | CIRCUIT TO A 30 AMP DISCONNECT FUSED AT 30 AMPS. SPECS | | | ON SHEET M-1 STATE THAT MOCP SHOULD BE 40 AMPS FOR THIS | | | UNIT. PROVIDE CORRECTIONS. NEC 440.22(C); FBC RE3702.11 | | | (DISCONNECT IS SHOWN AS A 30 AMP FRAME WITH 40 AMP | | | FUSES. 40 AMP FUSES WILL NOT FIT INTO A 30 AMP FRAME. | | | PROVIDE CORRECTION.) | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-09-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-14 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-14 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2017-09-14 15:52:14 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE COMPLETED PANEL SCHEDULE. CURRENTLY, PANEL | | | SCHEDULE DOES NOT SHOW ANY LOADS FOR EACH CIRCUIT, DOES | | | NOT SHOW WIRE SIZE, AND DOES NOT INDICATE AFCI OR GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8, 210.12, | | | 215.5, 408.4; FBC RE3706.2, RE3902; FBC 107.2.1 | | | 2. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. NEC 250.94; FBC RE3609.3 | | | 3. SERVICE DISCONNECT ON POWER PLAN IS SHOWN AS | | | NON-FUSED. OVERCURRENT PROTECTION IS REQUIRED AT THIS | | | LOCATION. PROVIDE CORRECTION. NEC 230.91; FBC RE | | | 3603.3.3 | | | 4. NOTE 6 STATES "PROVIDE ARC FAULT RECEPTACLES AS PER | | | NEC 210.12". CODE REQUIRES THE FOLLOWING: "ALL | | | 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH | | | CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, | | | HALLWAYS, OR SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI | | | PROTECTION". PROVIDE CORRECTION TO INCLUDE MORE THAN | | | RECEPTACLES. NEC 210.12; FBC RE3902.12 | | | 5. DUE TO THE TYPE OF LIGHT FIXTURES NOT CLARIFIED IN | | | CLOSETS, PROVIDE NOTE THAT LIGHT FIXTURES SHALL COMPLY | | | WITH NEC 410.16. NEC 410.16; FBC RE4003.12 | | | 6. DUE TO THE TYPE OF LIGHT FIXTURES NOT CLARIFIED IN | | | DAMP LOCATIONS, PROVIDE NOTE THAT LIGHT FIXTURES SHALL | | | COMPLY WITH NEC 410.10. NEC 410.10(D); FBC RE4003.11 | | | 7. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC CE R404.1 | | | 8. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE4002.14 | | | 9. PROVIDE A BLOCK NOTE INDICATING THE REQUIRED | | | SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS WHERE APPLICABLE FOR LOW VOLTAGE SYSTEMS, | | | FIRE ALARM, CCTV, PHONE AND DATA, WIRELESS SYSTEMS, | | | WALK-IN COOLERS, HOODS, ETC. FBC 105.1, 107.2.1 | | | 10. THE COVERED PATIO SHOWS 2 GFCI STANDARD OUTLETS IN | | | SUMMER KITCHEN. THESE OUTLETS ARE REQUIRED TO BE | | | WEATHER PROOF. PROVIDE CORRECTION. NEC 406.9; FBC RE | | | 4002.8 | | | 11. THE WATER HEATER SPECIFIED ON SHEET P.0.0.00 IS | | | SHOWN WITH 4500 WATT ELEMENTS. THE PANEL SCHEDULE SHOWS | | | A 35 AMP BREAKER FOR THIS UNIT, WHICH IS TOO LARGE PER | | | CODE. BREAKER SHOULD BE SIZED AT 125% OF THE LOAD, | | | WHICH WOULD BE A 25 AMP BREAKER. PROVIDE CORRECTION. | | | NEC 422.13; FBC RE3702.10 | | | 12. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC R314.3, R315.1; FBC 107.2.1 | | | 13. RECEPTACLES FOR GARAGE DOOR OPENERS, CIRCUITS | | | B2SO-12 AND B2SO-13, REQUIRE GFCI PROTECTION. PROVIDE | | | CORRECTION. NEC 210.8; FBC RE3902.2 | | | 15. CONDENSING UNIT IS SHOWN BEING FED FROM A 30 AMP | | | CIRCUIT TO A 30 AMP DISCONNECT FUSED AT 30 AMPS. SPECS | | | ON SHEET M-1 STATE THAT MOCP SHOULD BE 40 AMPS FOR THIS | | | UNIT. PROVIDE CORRECTIONS. NEC 440.22(C); FBC RE3702.11 | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-11-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-11-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-11-06 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-09-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-09-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-09-22 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-03-06 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-03-06 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-03-06 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2018-03-06 13:46:00 | TO SAK DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-02-28 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-02-28 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-02-05 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-02-02 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-01-10 |
Time |
14:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-11-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-11-30 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-11-01 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-09-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-29 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-01 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-01-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-01-31 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-01-31 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-09-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-09-20 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-09-19 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2017-09-20 11:36:17 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2018-03-06 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-03-06 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-03-06 |
Time |
16:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2018-01-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-01-18 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-01-17 |
Time |
17:49 |
Sent To |
|
|
| Notes |
| 2018-01-18 07:53:44 | 3RD REVIEW FBC-2014 MECHANICAL | | | PERMIT #17090021 | | | 1/18/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) MECHANICAL COMMENTS FROM THE 1ST AND 2ND REVIEWS | | | HAVE NOT BEEN ADDRESSED AND STILL EXIST, AND NO | | | EXPLANATION WAS PROVIDED IN THE RESPONSE NARRATIVE FROM | | | THE ARCHITECT. | | | | | | I HAVE REPRINTED THE COMMENTS AGAIN BELOW- PLEASE | | | COMPLY. | | | | | | 1) THE M1 HVAC FLOOR PLAN SHOWING A LAYOUT FOR A | | | 3-BEDROOM HOUSE DOES NOT MATCH THE ARCHITECTURAL FLOOR | | | AND RCP PLANS WHICH INDICATE THE HOUSE WILL BE | | | CONVERTED TO A SALES OFFICE CENTER. PLEASE PROVIDE | | | CORRECT ROOM IDENTIFCATION LABELS ON THE PLAN. | | | | | | 2) PROVIDE VENTILATION CALCULATIONS FOR ALL OCCUPIED | | | ROOMS AND SPACES USING EITHER NATURAL VENTILATION PER | | | SECTION 402, OR MECHANICAL PER SECTION 403. | | | | | | 3) SALES OFFICES ARE BUSINESS OCCUPANCIES AND FALL | | | UNDER THE COMMERCIAL PROVISIONS OF THE FLORIDA ENERGY | | | CONSERVATION CODE- 2014: A) REFER TO SECTION C403.2.1 | | | AND PROVIDE AC COOLING AND HEATING CALCULATIONS IN | | | ACCORDANCE WITH ASHRAE/ACCA STANDARD 183 OR ACCA MANUAL | | | N. B) THE SUBMITTED ENERGY CALCULATION FORM R405-2014 | | | CAN NOT BE USED TO SHOW COMPLIANCE FOR A COMMERCIAL | | | BUILDING. REFER TO SECTION C101.5.1 AND PROVIDE A | | | COMMERCIAL COMPLIANCE SUBMITTAL. | | | | | | 4) THE M1 PLAN SHEET NEEDS TO BE PLACED IN THE PLAN | | | SETS PROPERLY SO THAT ALL INFORMATION CAN BE READ. THE | | | CURRENT SHEET IS STAPLED TO CLOSE TO THE LEFT MARGIN | | | MAKING SOME OF THE NOTES AND DETAILS UNABLE TO BE READ | | | AND REVIEWED- PLEASE FIX THE PROBLEM- SECTION 107 WPB | | | AMENDMENTS TO THE FBC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-11-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-08 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-08 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2017-11-08 17:23:04 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17090021 | | | 11/8/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | COMMENTS FROM THE 1ST REVIEW HAVE NOT BEEN ADDRESSED. I | | | HAVE REPRINTED THEM BELOW- PLEASE COMPLY. | | | | | | 1) THE M1 HVAC FLOOR PLAN SHOWING A LAYOUT FOR A | | | 3-BEDROOM HOUSE DOES NOT MATCH THE ARCHITECTURAL FLOOR | | | AND RCP PLANS WHICH INDICATE THE HOUSE WILL BE | | | CONVERTED TO A SALES OFFICE CENTER. PLEASE PROVIDE | | | CORRECT ROOM IDENTIFCATION LABELS ON THE PLAN. | | | | | | 2) PROVIDE VENTILATION CALCULATIONS FOR ALL OCCUPIED | | | ROOMS AND SPACES USING EITHER NATURAL VENTILATION PER | | | SECTION 402, OR MECHANICAL PER SECTION 403. | | | | | | 3) SALES OFFICES ARE BUSINESS OCCUPANCIES AND FALL | | | UNDER THE COMMERCIAL PROVISIONS OF THE FLORIDA ENERGY | | | CONSERVATION CODE- 2014: A) REFER TO SECTION C403.2.1 | | | AND PROVIDE AC COOLING AND HEATING CALCULATIONS IN | | | ACCORDANCE WITH ASHRAE/ACCA STANDARD 183 OR ACCA MANUAL | | | N. B) THE SUBMITTED ENERGY CALCULATION FORM R405-2014 | | | CAN NOT BE USED TO SHOW COMPLIANCE FOR A COMMERCIAL | | | BUILDING. REFER TO SECTION C101.5.1 AND PROVIDE A | | | COMMERCIAL COMPLIANCE SUBMITTAL. | | | | | | 4) THE M1 PLAN SHEET NEEDS TO BE PLACED IN THE PLAN | | | SETS PROPERLY SO THAT ALL INFORMATION CAN BE READ. THE | | | CURRENT SHEET IS STAPLED TO CLOSE TO THE LEFT MARGIN | | | MAKING SOME OF THE NOTES AND DETAILS UNABLE TO BE READ | | | AND REVIEWED- PLEASE FIX THE PROBLEM- SECTION 107 WPB | | | AMENDMENTS TO THE FBC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-09-25 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-09-25 |
Time |
17:37 |
Sent To |
|
|
| Notes |
| 2017-09-25 17:53:43 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17090021 | | | 9/25/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE M1 HVAC FLOOR PLAN SHOWING A LAYOUT FOR A | | | 3-BEDROOM HOUSE DOES NOT MATCH THE ARCHITECTURAL FLOOR | | | AND RCP PLANS WHICH INDICATE THE HOUSE WILL BE | | | CONVERTED TO A SALES OFFICE CENTER. PLEASE PROVIDE | | | CORRECT ROOM IDENTIFCATION LABELS ON THE PLAN. | | | | | | 2) PROVIDE VENTILATION CALCULATIONS FOR ALL OCCUPIED | | | ROOMS AND SPACES USING EITHER NATURAL VENTILATION PER | | | SECTION 402, OR MECHANICAL PER SECTION 403. | | | | | | 3) SALES OFFICES ARE BUSINESS OCCUPANCIES AND FALL | | | UNDER THE COMMERCIAL PROVISIONS OF THE FLORIDA ENERGY | | | CONSERVATION CODE- 2014: A) REFER TO SECTION C403.2.1 | | | AND PROVIDE AC COOLING AND HEATING CALCULATIONS IN | | | ACCORDANCE WITH ASHRAE/ACCA STANDARD 183 OR ACCA MANUAL | | | N. B) THE SUBMITTED ENERGY CALCULATION FORM R405-2014 | | | CAN NOT BE USED TO SHOW COMPLIANCE FOR A COMMERCIAL | | | BUILDING. REFER TO SECTION C101.5.1 AND PROVIDE A | | | COMMERCIAL COMPLIANCE SUBMITTAL. | | | | | | 4) THE M1 PLAN SHEET NEEDS TO BE PLACED IN THE PLAN | | | SETS PROPERLY SO THAT ALL INFORMATION CAN BE READ. THE | | | CURRENT SHEET IS STAPLED TO CLOSE TO THE LEFT MARGIN | | | MAKING SOME OF THE NOTES AND DETAILS UNABLE TO BE READ | | | AND REVIEWED- PLEASE FIX THE PROBLEM- SECTION 107 WPB | | | AMENDMENTS TO THE FBC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2018-03-06 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-03-06 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-03-06 |
Time |
16:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2018-02-28 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-02-28 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-02-28 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2018-02-28 08:47:47 | DENIED | | | | | | 1. THIS IS THE SECOND REQUEST, SHT.P.1.3.00C SHOWS | | | DRINKING FOUNTAIN ON THE LAYOUT AND P.3.1.00C ON THE | | | ISOMERIC IS MISSING, ALSO THE RE-VENT FOR THE WASHING | | | MACHINE DOES NOT CONNECT, PLEASE RECTIFY. FBC WPB | | | AMENDMENTS SEC.107.2.1 | | | | | | 2. ADA BATHROOM DOES NOT COMPLY THE REQUIRED CLEARANCE | | | AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP | | | THE WATER CLOSET, ASSOCIATED GRAB BARS, DISPENSERS, | | | SANITARY NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, | | | ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AND CLEARANCES | | | REQUIRED AT OTHER FIXTURES, AND THE TURNING SPACE. NO | | | OTHER FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN | | | THE REQUIRED WATER CLOSET CLEARANCE. FBC ACC 604.3.2 | | | OVERLAP. CLEARANCE AROUND A WATER CLOSET SHALL BE 60 | | | INCHES (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM | | | THE SIDE WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED | | | PERPENDICULAR FROM THE REAR WALL. FBC ACC 604.3.1 SIZE. | | | | | | A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS TIME | | | AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE GENERATED | | | UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS DETACHED AND MARK | | | VOID..\ | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | [email protected] | | | 561-805-6720 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2018-01-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-24 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-24 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2018-01-24 10:58:35 | 3RD REVIEW: FBC 2014 5TH EDITION | | | | | | | | | PREVIOUS PLUMBING COMMENTS: NOT COMPLIED | | | | | | 2. SHT.A-4.2.02SO THE GRAB BARS SHALL BE SHOWN TO BE | | | MEASURED FROM THE GRIPPING SURFACE TO THE FINISHED | | | FLOOR. PER FBC ACC 609.4 | | | | | | 3. THE COAT HOOK SHALL BE A MAXIMUM OF 48" OF THE | | | FINISHED FLOOR PER FBC ACC 308 SHT. A-4.2.02SO SHOWS IT | | | AT 54" | | | | | | 4. AS THIS PERMIT IS FOR A BUSINESS OCCUPANCY THE | | | BATHING FACILITIES WHICH ARE THE TWO FULL BATHROOMS | | | SHALL COMPLY WITH FBC ACC 213 YOU MAY WANT TO REQUEST | | | FROM THE BUILDING OFFICIAL SOME RELIEF BY MAKING THESE | | | BATHROOM NON USABLE FOR DISPLAY ONLY. THIS CAN BE DONE | | | BY WRITING A LETTER TO ROBERT BROWN AND PLACING A NOTE | | | ON THE PLAN STATING NON USABLE BATHROOM, WATER NOT TO | | | BE CONNECTED TO FIXTURES. | | | | | | | | | NEW COMMENT: | | | | | | 1. THE PLAN SET HAS TWO SHT.P.1.3.00C AND P.3.1.00C ONE | | | SHOWS DRINKING FOUNTAIN THE OTHER DOES NOT PLEASE | | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-11-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-16 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-16 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2017-11-16 16:40:28 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | | | | PREVIOUS PLUMBING COMMENTS: NOT COMPLIED | | | | | | 4. SHT. P.1.3.00B KEY NOTE #2 SHALL COMPLY WITH FBC PL | | | 504.6 REQUIREMENTS FOR DISCHARGE PIPING. | | | THE DISCHARGE PIPING SERVING A PRESSURE RELIEF VALVE, | | | TEMPERATURE RELIEF VALVE OR COMBINATION THEREOF SHALL: | | | 2. DISCHARGE THROUGH AN AIR GAP LOCATED IN THE SAME | | | ROOM AS THE WATER HEATER. | | | | | | 5. SHT. P.1.3.00B KEY NOTE #5 SHALL COMPLY WITH FBC PL | | | 802.1.6 DOMESTIC DISHWASHING MACHINES. | | | DOMESTIC DISHWASHING MACHINES SHALL DISCHARGE | | | INDIRECTLY THROUGH AN AIR GAP OR AIR BREAK INTO A | | | STANDPIPE OR WASTE RECEPTOR IN ACCORDANCE WITH SECTION | | | 802.2, OR DISCHARGE INTO A WYE-BRANCH FITTING ON THE | | | TAILPIECE OF THE KITCHEN SINK OR THE DISHWASHER | | | CONNECTION OF A FOOD WASTE GRINDER. THE WASTE LINE OF A | | | DOMESTIC DISHWASHING MACHINE DISCHARGING INTO A KITCHEN | | | SINK TAILPIECE OR FOOD WASTE GRINDER SHALL CONNECT TO A | | | DECK-MOUNTED AIR GAP OR THE WASTE LINE SHALL RISE AND | | | BE SECURELY FASTENED TO THE UNDERSIDE OF THE SINK RIM | | | OR COUNTER. | | | | | | 7. THE 4" VENT LOCATED AT THE END OF THE RUN FOR THE | | | MASTER BATH TOILET IS A HORIZONTAL DRY VENT WHICH IS | | | NOT CODE COMPLAINT THAT VENT IS NOT REQUIRED. PER FBC | | | PL 905.3 - 905.5 | | | | | | NEW COMMENTS: | | | | | | 1. THE CLEARANCE FOR THE TOILET SHALL COMPLY WITH FBC | | | ACC 604.3.2 THE LAVATORY CAN NOT ENCROACH ON THE 60" | | | CLEAR FLOOR SPACE, THE WIDTH OF THE BATHROOM WILL NEED | | | TO BE A MIN OF 7' 1" TO ACCOMMODATE THE CLEARANCES. | | | | | | 2. THE GRAB BARS SHALL BE MEASURED FROM THE GRIPPING | | | SURFACE TO THE FINISHED FLOOR. PER FBC ACC 609.4 | | | | | | 3. THE COAT HOOK SHALL BE A MAXIMUM OF 48" OF THE | | | FINISHED FLOOR PER FBC ACC 308 | | | | | | 4. AS THIS PERMIT IS FOR A BUSINESS OCCUPANCY THE | | | BATHING FACILITIES WHICH ARE THE TWO FULL BATHROOMS | | | SHALL COMPLY WITH FBC ACC 213 YOU MAY WANT TO REQUEST | | | FROM THE BUILDING OFFICIAL SOME RELIEF BY MAKING THESE | | | BATHROOM NON USABLE FOR DISPLAY ONLY. THIS CAN BE DONE | | | BY WRITING A LETTER TO ROBERT BROWN AND PLACING A NOTE | | | ON THE PLAN STATING NON USABLE BATHROOM, WATER NOT TO | | | BE CONNECTED TO FIXTURES. | | | | | | 5. THE LAVATORY IN THE ACCESSIBLE BATHROOM SHALL COMPLY | | | WITH FBC PL 416.5 TEMPERED WATER FOR PUBLIC | | | HAND-WASHING FACILITIES. | | | TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES AND | | | GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET FACILITIES | | | PROVIDED FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED | | | WATER SHALL BE DELIVERED THROUGH AN APPROVED | | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | | 1070 OR CSA B125.3. | | | | | | 6. THE BRANCH FITTINGS IN THE BUILDING DRAIN THAT ARE | | | FOR THE DRINKING FOUNTAIN AND KITCHEN ARE SHOWN WITH | | | THE DIRECTION OF FLOW FACING THE WRONG DIRECTION ON THE | | | RISER AND THE FLOOR PLAN PLEASE CLARIFY. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | 7. THE VENT FOR THE WATER FOUNTAIN IS SHOWN AS A DRY | | | HORIZONTAL DRY VENT THAT IS NOT CODE COMPLIANT THE VENT | | | SHOULD CONNECT TO THE TOP OF THE STACK FOR THE WATER | | | FOUNTAIN. PER FBC PL 905.3/ 905.4/ 910.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-09-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-29 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-27 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2017-09-27 18:02:09 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | | | | PLUMBING COMMENTS: | | | | | | 1. AT LEAST ONE OF THE BATHROOMS SHALL BE MADE FULLY | | | ACCESSIBLE. PER FBC ACC 213.1 | | | | | | 2. THE ACCESSIBLE BATHROOM SHALL COMPLY WITH THE | | | FOLLOWING CODE SECTIONS. FBC ACC 603, 604, 606 , 609 | | | PLEASE PROVIDE DIMENSIONS AND SHOW CLEAR FLOOR SPACE ON | | | THE PLANS . PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. PLEASE SHOW COMPLIANCE OF WATER FOUNTAIN PER .FBC | | | ACC 602 | | | | | | 4. SHT. P.1.3.00B KEY NOTE #2 SHALL COMPLY WITH FBC PL | | | 504.6 REQUIREMENTS FOR DISCHARGE PIPING. | | | THE DISCHARGE PIPING SERVING A PRESSURE RELIEF VALVE, | | | TEMPERATURE RELIEF VALVE OR COMBINATION THEREOF SHALL: | | | 2. DISCHARGE THROUGH AN AIR GAP LOCATED IN THE SAME | | | ROOM AS THE WATER HEATER. | | | | | | 5. SHT. P.1.3.00B KEY NOTE #5 SHALL COMPLY WITH FBC PL | | | 802.1.6 DOMESTIC DISHWASHING MACHINES. | | | DOMESTIC DISHWASHING MACHINES SHALL DISCHARGE | | | INDIRECTLY THROUGH AN AIR GAP OR AIR BREAK INTO A | | | STANDPIPE OR WASTE RECEPTOR IN ACCORDANCE WITH SECTION | | | 802.2, OR DISCHARGE INTO A WYE-BRANCH FITTING ON THE | | | TAILPIECE OF THE KITCHEN SINK OR THE DISHWASHER | | | CONNECTION OF A FOOD WASTE GRINDER. THE WASTE LINE OF A | | | DOMESTIC DISHWASHING MACHINE DISCHARGING INTO A KITCHEN | | | SINK TAILPIECE OR FOOD WASTE GRINDER SHALL CONNECT TO A | | | DECK-MOUNTED AIR GAP OR THE WASTE LINE SHALL RISE AND | | | BE SECURELY FASTENED TO THE UNDERSIDE OF THE SINK RIM | | | OR COUNTER. | | | | | | 6. SHT. P.1.3.00B KEY NOTE #6 SHALL COMPLY WITH FBC PL | | | 708.3.5 BUILDING DRAIN AND BUILDING SEWER JUNCTION. | | | THERE SHALL BE A CLEANOUT NEAR THE JUNCTION OF THE | | | BUILDING DRAIN AND THE BUILDING SEWER. THE JUNCTION OF | | | THE BUILDING DRAIN AND SEWER SHALL BE 30" MAX FROM | | | BUILDING. 15' DOES NOT COMPLY. | | | | | | 7. THE 4" VENT LOCATED AT THE END OF THE RUN FOR THE | | | MASTER BATH TOILET IS A HORIZONTAL DRY VENT WICH IS NOT | | | CODE COMPLAINT THAT VENT IS NOT REQUIRED. PER FBC PL | | | 905.3 - 905.5 | | | | | | 8. PLEASE LABEL ALL FIXTURES ON WATER RISER. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2017-11-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-11-20 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-11-20 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-09-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-09-20 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-09-19 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2017-09-20 10:01:19 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOF PERMIT REQUIRED. | | | 2. PROVIDE PRODUCT APPROVAL FOR PROPOSED MODIFIED | | | BITUMEN UNDERLAYMENT. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
JR |
Date |
2018-02-02 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-02-02 |
Time |
14:40 |
Sent To |
PC |
|
| Notes |
| 2018-02-02 14:40:50 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 02.02.2018 | | | PERMIT NO.: 17090021 | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, | | | ALL LANDSCAPING FOR THE SUBJECT RESIDENCE SHALL BE | | | INSTALLED IN ACCORDANCE WITH APPROVED PLANS (PERMIT | | | #17110882) AND PASS INSPECTION. | | | | | | 2. PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF | | | OCCUPANCY WITHIN THE DEVELOPMENT, ALL COMMON AREA | | | ELEMENTS (INCLUDING SIDEWALKS, LANDSCAPING, ENTRY, | | | STREETSCAPE, CONGRESS AVENUE BUFFER, ETC.) SHALL BE | | | INSTALLED (IN ACCORDANCE WITH APPROVED/PERMITTED PLANS. | | | | | | 3. PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF | | | OCCUPANCY WITHIN THE DEVELOPMENT, THE FOUNTAINS | | | REQUIRED BY THE DESIGN GUIDELINES SHALL BE INSTALLED IN | | | ALL LAKE AREAS THAT SEPARATE THE DEVELOPMENT FROM THE | | | EXISTING RESIDENTIAL NEIGHBORHOODS. | | | | | | 4. THE USE OF THE STRUCTURE AS A TEMPORARY SALES OFFICE | | | SHALL NOT EXCEED TWO (2) YEARS (FROM THE DATE OF | | | ISSUANCE OF THE CO), UNLESS AN EXTENSION HAS BEEN | | | GRANTED BY THE PLANNING & ZONING ADMINISTRATOR. | | | | | | 5. THE MODEL DWELLING/SALES OFFICE SHALL BE NOT BE USED | | | TO PROMOTE THE SALE OF LOTS OR DWELLINGS NOT LOCATED IN | | | THE PROJECT. | | | | | | 6. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, | | | AT LEAST FIVE (5) OFF-STREET PARKING SPACES SHALL BE | | | PROVIDED. | | | | | | 7. THE MODEL DWELLING/SALES OFFICE SHALL NOT BE | | | ILLUMINATED (EXCEPT AS IS CUSTOMARY FOR A RESIDENTIAL | | | DWELLING) OR USED FOR ANY BUSINESS ACTIVITY LATER THAN | | | 9:00PM. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2017-11-30 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-11-30 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-11-30 |
Time |
16:25 |
Sent To |
PC |
|
| Notes |
| 2017-11-30 16:26:13 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 11.30.2017 | | | PERMIT NO.: 17090021 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PRIOR TO THE ISSUANCE OF ANY PERMITS FOR THE SINGLE | | | FAMILY DEVELOPMENT WITHIN BANYAN CAY, A MINOR PLANNED | | | DEVELOPMENT AMENDMENT SHALL BE SUBMITTED TO THE | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION, | | | AND APPROVED. THE MINOR AMENDMENT SHOULD PROVIDE FOR | | | ALL OF THE MODELS THAT ARE PROPOSED, AND SHOW | | | COMPLIANCE WITH THE BANYAN CAY DESIGN GUIDELINES, | | | INCLUDING COLOR SCHEMES, THE MINIMUM NUMBER OF EXTERIOR | | | MODIFICATIONS THAT ARE REQUIRED, AND THE MINIMUM NUMBER | | | OF UNIT LANDSCAPE PLANS. | | | | | | 6. PLEASE NOTE THAT PRIOR TO THE ISSUANCE OF THE FIRST | | | CERTIFICATE OF OCCUPANCY, ALL COMMON AREA LANDSCAPING | | | SHALL BE INSTALLED (ENTRY, STREETSCAPE, CONGRESS AVENUE | | | BUFFER, ETC.). | | | | | | 7. PLEASE NOTE THAT PRIOR TO THE ISSUANCE OF THE FIRST | | | CERTIFICATE OF OCCUPANCY, THE FOUNTAINS REQUIRED BY THE | | | DESIGN GUIDELINES SHALL BE INSTALLED IN ALL LAKE AREAS | | | THAT SEPARATE THE DEVELOPMENT FROM THE EXISTING | | | RESIDENTIAL NEIGHBORHOODS. | | | | | | 8. ACCORDING TO THE APPROVED CROSS SECTION FOR THE 40 | | | FOOT WIDE PRIVATE ROADWAY, AS APPROVED IN THE DESIGN | | | GUIDELINES, THERE IS TO BE A 4 FOOT MEANDERING SIDEWALK | | | ALONG THE STREET THAT MEANDERS FROM THE RIGHT-OF-WAY | | | INTO THE SIDEWALK EASEMENT, BACK INTO THE RIGHT-OF-WAY, | | | ETC. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
JROACH |
Date |
2017-09-25 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-09-25 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2017-09-25 16:23:51 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 09.25.2017 | | | PERMIT NO.: 17090021 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PRIOR TO THE ISSUANCE OF ANY PERMITS FOR THE SINGLE | | | FAMILY DEVELOPMENT WITHIN BANYAN CAY, A MINOR PLANNED | | | DEVELOPMENT AMENDMENT SHALL BE SUBMITTED TO THE | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION, | | | AND APPROVED. THE MINOR AMENDMENT SHOULD PROVIDE FOR | | | ALL OF THE MODELS THAT ARE PROPOSED, AND SHOW | | | COMPLIANCE WITH THE BANYAN CAY DESIGN GUIDELINES, | | | INCLUDING COLOR SCHEMES, THE MINIMUM NUMBER OF EXTERIOR | | | MODIFICATIONS THAT ARE REQUIRED, AND THE MINIMUM NUMBER | | | OF UNIT LANDSCAPE PLANS. | | | | | | 2. PRIOR TO THE ISSUANCE OF ANY PERMITS FOR THE SINGLE | | | FAMILY DEVELOPMENT WITHIN BANYAN CAY, THE PLAT SHALL BE | | | RECORDED TO ESTABLISH THE INDIVIDUAL FEE-SIMPLE LOTS. | | | WHILE THE PLAT WAS PREVIOUSLY APPROVED, IT IS REQUIRED | | | THAT A MINOR SUBDIVISION APPLICATION BE SUBMITTED TO | | | THE DEVELOPMETN SERVICES DEPARTMENT ? PLANNING DIVISION | | | AND BE APPROVED BY THE CITY COMMISSION, AS THE NAME OF | | | THE PLAT HAS CHANGED, THE LOCATIONS OF THE EASEMENTS | | | HAS CHANGED, ETC. | | | | | | 3. THE DIMENSIONS OF THE PROPOSED SITE SETBACKS ON THE | | | SITE PLAN DIFFER FROM THAT WHICH IS SHOWN ON THE | | | SURVEY. ENSURE THAT ALL PLANS ARE CONSISTENT AND | | | ACCURATE. | | | | | | 4. THE SITE PLAN SHOULD IDENTIFY THE LOCATION OF ANY | | | PROPOSED MECHANCIAL EQUIPMENT (I.E. A/C CONDENSING | | | UNITS). PLEASE NOTE THAT MECHANICAL EQUIPMENT MAY NOT | | | ENCROACH MORE THAN FOUR (4) FEET INTO ANY REQUIRED | | | PRINCIPAL STRUCTURE SETBACK. | | | | | | 5. ALL LANDSCAPING SHALL BE SUBMITTED AND APPROVED AS A | | | SEPARATE LANDSCAPE PERMIT. | | | | | | 6. PLEASE NOTE THAT PRIOR TO THE ISSUANCE OF THE FIRST | | | CERTIFICATE OF OCCUPANCY, ALL COMMON AREA LANDSCAPING | | | SHALL BE INSTALLED (ENTRY, STREETSCAPE, CONGRESS AVENUE | | | BUFFER, ETC.). | | | | | | 7. PLEASE NOTE THAT PRIOR TO THE ISSUANCE OF THE FIRST | | | CERTIFICATE OF OCCUPANCY, THE FOUNTAINS REQUIRED BY THE | | | DESIGN GUIDELINES SHALL BE INSTALLED IN ALL LAKE AREAS | | | THAT SEPARATE THE DEVELOPMENT FROM THE EXISTING | | | RESIDENTIAL NEIGHBORHOODS. | | | | | | 8. ACCORDING TO THE APPROVED CROSS SECTION FOR THE 40 | | | FOOT WIDE PRIVATE ROADWAY, AS APPROVED IN THE DESIGN | | | GUIDELINES, THERE IS TO BE A 4 FOOT MEANDERING SIDEWALK | | | ALONG THE STREET THAT MEANDERS FROM THE RIGHT-OF-WAY | | | INTO THE SIDEWALK EASEMENT, BACK INTO THE RIGHT-OF-WAY, | | | ETC. | | | | | | 9. LANDSCAPE PLANS NEED TO SHOW THE PROPERTY | | | BOUNDARIES. | | | | | | 10. LANDSCAPE PLANS SHALL PROVIDE A TABLE SHOWING | | | COMPLIANCE WITH SECTION 94-442(B)(2)A. OF THE CITY?S | | | ZONING AND LAND DEVELOPMENT REGULATIONS (REQUIRED | | | AMOUNT OF PLANT MATERIAL). | | | | | | 11. IT APPEARS ON THE LANDSCAPE PLAN THAT THE A LARGE | | | SHAD TREE IS PROPOSED TO BE INSTALLED IN THE UTILTY | | | EASEMENT. PLANTING IN AN EASEMENT SHALL REQUIRE THE | | | CONSENT OF ALL EASEMENT HOLDERS. | | | | | | 12. IT APPEARS THAT THE PROPOSED LANDSCAPE PLAN HAS NOT | | | ACCOUNTED FOR THE APPROVED STREETSCAPE PLAN. PLEASE | | | ENSURE THAT ALL PLANS ARE COMPATIBLE AND ARE SHOWN IN | | | CONTEXT WITH ONE ANOTHER. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
|