| Plan Review Stops For Permit 17090002 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-11-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-11-22 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-11-22 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-10-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-10-17 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-10-17 |
Time |
09:59 |
Sent To |
M |
|
| Notes |
| 2017-10-17 11:54:50 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. OWNER/AGENT TO SIGN ENERGY SUBMITTAL. | | | 2. PROVIDE ICYNENE ICC/ES REPORT FOR PROPOSED | | | INSULATION. INDICATE WHICH PRODUCT WILL BE INSTALLED. | | | PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS AT TIME | | | OF INSPECTION PER ES REPORT REQUIREMENTS. | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-11-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-15 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-15 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-26 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-26 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2017-09-26 11:19:38 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE3901.12 | | | 2. LIGHTING IN MASTER CLOSETS SHOWS STANDARD RECESS | | | LIGHTS. PER CODE: "LIGHTING WITH OPEN OR PARTIALLY | | | ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS | | | SHALL NOT BE PERMITTED IN CLOTHES CLOSETS". PROVIDE | | | CORRECTION. NEC 410.16; FBC RE4003.12 | | | 3. PANEL SCHEDULE SHOWS A 50 AMP BREAKER FOR THE NEW | | | AHU AND A 30 AMP BREAKER FOR THE NEW CU. SPECS ON THE | | | MECHANICAL SHEETS REQUIRE A 30 AMP BREAKER FOR THE AHU | | | AND A 25 AMP BREAKER FOR THE CU. PROVIDE CORRECTION. | | | THE BRANCH CIRCUIT OVERCURRENT PROTECTION DEVICE RATING | | | SHALL BE THE SIZE AND TYPE MARKED ON THE EQUIPMENT. NEC | | | 440.22(C); FBC RE3702.11 | | | 4. PROVIDE PANEL SCHEDULE FOR PANEL A, INDICATING ANY | | | NEW OR ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR | | | THESE CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE | | | APPLICABLE TO COMPLY WITH CODE. NEC 210.8, 210.12, | | | 215.5, 408.4; FBC RE3706.2, RE3902 | | | 5. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE4002.14 | | | 6. A GFCI PROTECTED OUTLET ON A 20 AMP CIRCUIT IS | | | REQUIRED WITHIN 3 FEET OF EACH BASIN IN MASTER BATH. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | 3703.4, 3901.6 | | | 7. PROVIDE COMPLIANCE: ALL 120-VOLT, SINGLE PHASE, 15 | | | AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS IN | | | DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, | | | RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR AREAS | | | OR ROOMS, SHALL HAVE AFCI PROTECTION. A NOTE WILL | | | SUFFICE. NEC 210.12; FBC RE3902.12 | | | 8. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC CE R404.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2017-11-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-11-21 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-11-21 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2017-11-21 12:47:14 | A SEPARATE PERMIT IS REQUIRED FOR THE GAS. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-09-29 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2017-09-29 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2017-09-29 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2017-09-29 15:56:14 | FAILED 9/29/17 LAC | | | | | | 1. NEED SEPARATE PERMIT FOR GAS IS REQUIRED FBC A 105.3 | | | | | | 2. SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2014 FGC SEC.410.1. | | | | | | 3. INDICATE ON BOTH GAS DRAWINGS HOW THE PIPING THOUGH | | | THE EXTERIOR WILL BE PROTECTED. WPB AMENDMENTS TO THE | | | FBC SEC. 107.2.1. | | | | | | 4. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH FBC-2014 FUEL GAS CODE SEC. 402.2, AND | | | 301.3 OR 2014 FBC-RES. SEC. G2404.3. GAS APPLIANCES | | | SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS | | | FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT | | | THE TIME OF INSPECTION. FGC SEC.305.1, FBC-RES. | | | SEC.G2408.1. | | | | | | 5. SUBMIT COMBUSTION AIR CALCULATIONS FOR THE GAS | | | APPLIANCES. WHERE COMBUSTION AIR IS PROVIDED BY THE | | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR. FGC | | | SEC.304.9.3 OR FBCR G2407.9.3. | | | | | | 6. SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2014 FBC-FUEL | | | GAS SECS. 401.4, 401.8 THRU 402.6.1 AND TABLES 402.4 | | | (1) THRU 402.4 (37) OR 2014 FBC-RES. SEC. G2412.4, | | | G2412.8, G2413.1, G2413.2, & G2413.3. | | | | | | 7. THE BTU LOAD OF THE GAS SYSTEM MUST BE ADDED INTO | | | THE TOTAL BTU LOAD ON THE FUTURE GAS SYSTEM TO ENSURE | | | THE EXISTING SYSTEM IS PROPERLY SIZED. THE LOAD OF THE | | | FUTURE RANGE IN NOT CALCULATED ON THE GAS PIPING | | | ISOMETRIC PAGE P-1. IF UNDERSIZED, THE EXISTING SYSTEM | | | MUST BE REDONE TO ENSURE A SAFE OPERATING SYSTEM. FGC | | | SEC. 401.4, 401.8, 402.1, 402.2, 402.3 OR FBCR | | | SECS.G2412.4, G2412.8, G2413.1, G2413.2, G2413.3. | | | | | | 8. NEED A SHUTOFF VALVE AND HARD CAP FOR FUTURE RANGE | | | SHOW ON GAS ISOMERIC P-1 APPLIANCE SHUTOFF IFGC 409.5, | | | APPLIANCE CONNECTION IFGC 404.15, 411. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-09-07 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-09-07 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-09-07 |
Time |
14:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-11-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-11-22 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-10-24 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-10-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-10-18 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-09-01 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2017-12-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-12-08 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-12-08 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2017-12-08 11:13:49 | $236.59 PAID. MU-2017-032597. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-11-22 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-11-22 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2017-11-28 08:57:22 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-10-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-10-17 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-10-17 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2017-10-17 11:36:30 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-11-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-11-22 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-11-22 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-10-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-10-18 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-10-18 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-11-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-11-21 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-11-21 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-09-29 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2017-09-29 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2017-09-29 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2017-09-29 15:47:30 | DENIED 9/29/17 LAC | | | | | | 1. THE SHOWER IS SIZED AS A 3? PER CODE A 2? IS THE | | | MINIMUM, HOW MANY DFU?S (GPM) IS THE SHOWER HEAD TO | | | DRAIN TO THE SHOWER. FBC P3004.1, P3201.7 | | | | | | 2. PLANS CALL FOR A STEAM SHOWER PLEASE PROVIDE | | | LOCATION AND SPECIFICATION FOR STEAM GENERATOR, PLEASE | | | PROVIDE MANUFACTURE SPECIFICATION. IF THE STEAM UNIT IS | | | UNDER A THE SHOWER SEAT. HOW IS THE STEAM ENTERING THE | | | SHOWER? PLEASE CLARIFY WHAT TYPE OF PROTECTION IS BEING | | | USED AND SHOW WHERE IT GOING IN THE SHOWER. FBC | | | AMENDMENTS 107.2.1A-2 | | | | | | 3. SHOWER PAN IS NOT RECEDED IT WILL REQUIRE LINING FBC | | | P2709.2 | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2017-10-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-10-17 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-10-17 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-09-07 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-09-07 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-09-07 |
Time |
14:06 |
Sent To |
|
|
| Notes |
|
|