| Plan Review Stops For Permit 17081495 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-10-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-10-16 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-10-16 |
Time |
18:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-09-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-20 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-09-20 |
Time |
17:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-10-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-25 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-25 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-09-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-19 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-19 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2017-09-19 08:45:40 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. RISER DIAGRAM SHOWS 3/0 WIRE ON A 225 AMP BREAKER | | | FEEDING PANEL A. 3/0 WIRE IS NOT RATED FOR 225 AMPS. | | | PROVIDE CORRECTION. NEC 310.15(B)(16) | | | 2. PROVIDE NOTE THAT ANY LOW VOLTAGE WORK, INCLUDING | | | FIRE ALARM, WILL BE UNDER SEPARATE PERMIT. FBC 105.1 | | | 3. PLAN SHOWS ADDRESS AS 300 23RD ST., WHILE PERMIT | | | APPLICATION SHOWS THE ADDRESS AS 304 23RD ST. PROVIDE | | | CORRECT ADDRESS ON PLANS. FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-10-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-10-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-10-13 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-09-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-09-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-09-05 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2017-09-05 15:03:21 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) THE ADDRESS ON THE TITLE BLOCK MAY BE INCORRECT. THE | | | ACTUAL ADDRESS APPEARS TO BE 312 23RD ST, SUITE # 300. | | | | | | PLEASE REVIEW, VERIFY AND CONFIRM THAT THE ADDRESS IS | | | CORRECT AND MAKE ANY APPLICABLE CHANGES. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-10-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-25 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-11 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-26 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-31 |
Time |
12:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-10-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-10-20 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-10-20 |
Time |
16:11 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-09-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-09-18 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-09-18 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2017-09-18 10:04:40 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17081495 | | | 9/18/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) M2.1: IDENTIFY THE PURPOSE OF THE DUCTWORK | | | REPRESENTED BY DOTTED LINES ON THE PLAN AND LABELED AS | | | "EXISTING". ARE THESE RETURN AIR DUCTS OR OUTSIDE AIR | | | DUCTS? PLEASE NOTE THAT THE TRASH ROOM IS A PROHIBITED | | | SOURCE OF RETURN AIR PER SECTION 918.6 ITEMS #2 AND 5, | | | AND ALSO A PROHIBITED SOURCE OF OUTSIDE AIR PER SECTION | | | 401.4 ITEM #2. ADDITIONALLY, RETURN AIR SHALL NOT BE | | | TAKEN FROM | | | THE ADJACENT OCCUPANCY PER SECTION 601.5 FBC-14 | | | MECHANICAL, AND SECTION C402.4.9 FBC-14 ENERGY | | | CONSERVATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-10-16 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-10-16 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-10-16 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-26 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-26 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2017-09-26 12:51:09 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. A GREASE INTERCEPTOR MAYBE REQUIRED FOR THREE | | | COMPARTMENT SINK IF FOOD PREP OR COOKING IS DONE IN THE | | | AREA. IF THERE IS NO COOKING OR FOOD PREP PLEASE | | | PROVIDE A SIGNED AND SEALED LETTER STATING THAT FACT. | | | PER FBC PL 1003.3.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|