Plan Review Details - Permit 17081495
Plan Review Stops For Permit 17081495
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-10-16 Cont ID  
Sent By shill Date 2017-10-16 Time 18:04 Rev Time 0.00
Received By shill Date 2017-10-16 Time 18:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-09-20 Cont ID  
Sent By shill Date 2017-09-20 Time 17:42 Rev Time 0.00
Received By shill Date 2017-09-20 Time 17:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-10-25 Cont ID  
Sent By jpearson Date 2017-10-25 Time 14:27 Rev Time 0.00
Received By jpearson Date 2017-10-25 Time 14:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-09-19 Cont ID  
Sent By jpearson Date 2017-09-19 Time 08:45 Rev Time 0.00
Received By jpearson Date 2017-09-19 Time 08:45 Sent To  
Notes
2017-09-19 08:45:40CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. RISER DIAGRAM SHOWS 3/0 WIRE ON A 225 AMP BREAKER
 FEEDING PANEL A. 3/0 WIRE IS NOT RATED FOR 225 AMPS.
 PROVIDE CORRECTION. NEC 310.15(B)(16)
 2. PROVIDE NOTE THAT ANY LOW VOLTAGE WORK, INCLUDING
 FIRE ALARM, WILL BE UNDER SEPARATE PERMIT. FBC 105.1
 3. PLAN SHOWS ADDRESS AS 300 23RD ST., WHILE PERMIT
 APPLICATION SHOWS THE ADDRESS AS 304 23RD ST. PROVIDE
 CORRECT ADDRESS ON PLANS. FBC 107.2.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-10-13 Cont ID  
Sent By pleduc Date 2017-10-13 Time   Rev Time 0.00
Received By pleduc Date 2017-10-13 Time 09:32 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-09-06 Cont ID  
Sent By pleduc Date 2017-09-06 Time   Rev Time 0.00
Received By pleduc Date 2017-09-05 Time 14:58 Sent To  
Notes
2017-09-05 15:03:21THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THE ADDRESS ON THE TITLE BLOCK MAY BE INCORRECT. THE
 ACTUAL ADDRESS APPEARS TO BE 312 23RD ST, SUITE # 300.
  
 PLEASE REVIEW, VERIFY AND CONFIRM THAT THE ADDRESS IS
 CORRECT AND MAKE ANY APPLICABLE CHANGES.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-10-25 Cont ID  
Sent By jpearson Date 2017-10-25 Time 14:28 Rev Time 0.00
Received By jpearson Date 2017-10-11 Time 14:43 Sent To  
Notes
2017-10-12 14:43:49B16

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-09-26 Cont ID  
Sent By gjohnson Date 2017-09-26 Time 12:51 Rev Time 0.00
Received By gjohnson Date 2017-08-31 Time 12:40 Sent To  
Notes
2017-09-01 12:40:33B09

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-10-20 Cont ID  
Sent By ccole Date 2017-10-20 Time 16:22 Rev Time 0.00
Received By ccole Date 2017-10-20 Time 16:11 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-09-18 Cont ID  
Sent By ccole Date 2017-09-18 Time 09:42 Rev Time 0.00
Received By ccole Date 2017-09-18 Time 09:18 Sent To  
Notes
2017-09-18 10:04:401ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17081495
 9/18/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) M2.1: IDENTIFY THE PURPOSE OF THE DUCTWORK
 REPRESENTED BY DOTTED LINES ON THE PLAN AND LABELED AS
 "EXISTING". ARE THESE RETURN AIR DUCTS OR OUTSIDE AIR
 DUCTS? PLEASE NOTE THAT THE TRASH ROOM IS A PROHIBITED
 SOURCE OF RETURN AIR PER SECTION 918.6 ITEMS #2 AND 5,
 AND ALSO A PROHIBITED SOURCE OF OUTSIDE AIR PER SECTION
 401.4 ITEM #2. ADDITIONALLY, RETURN AIR SHALL NOT BE
 TAKEN FROM
 THE ADJACENT OCCUPANCY PER SECTION 601.5 FBC-14
 MECHANICAL, AND SECTION C402.4.9 FBC-14 ENERGY
 CONSERVATION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-10-16 Cont ID  
Sent By thunt Date 2017-10-16 Time 13:42 Rev Time 0.00
Received By thunt Date 2017-10-16 Time 13:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-09-26 Cont ID  
Sent By gjohnson Date 2017-09-26 Time 12:38 Rev Time 0.00
Received By gjohnson Date 2017-09-26 Time 10:44 Sent To  
Notes
2017-09-26 12:51:091ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. A GREASE INTERCEPTOR MAYBE REQUIRED FOR THREE
 COMPARTMENT SINK IF FOOD PREP OR COOKING IS DONE IN THE
 AREA. IF THERE IS NO COOKING OR FOOD PREP PLEASE
 PROVIDE A SIGNED AND SEALED LETTER STATING THAT FACT.
 PER FBC PL 1003.3.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  