Plan Review Details - Permit 17081240
| Plan Review Stops For Permit 17081240 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-09 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-09 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2018-08-02 08:01:45 | FIRE PUMP PERMIT BY OYTHERS JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-09-13 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-09-13 |
Time |
16:05 |
Sent To |
M |
|
| Notes |
| 2017-09-13 16:06:31 | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | | NFPA 70 2011 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NO ELECTRIC SHOWN FOR PROPOSED FIRE PUMP AND CONTROLER. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-07-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-07-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-07-27 |
Time |
13:14 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-08-30 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-08-30 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-08-30 |
Time |
10:17 |
Sent To |
E |
|
| Notes |
| 2017-08-30 10:44:42 | 4396 EASLEY DRIVE - DEWATERING BUILDING | | | FS PERMIT #17081240 | | | UGFIRELINE: #16020206 | | | BUILDING MASTER #15060563 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE PLANS DO NOT INDICATE AN ADDRESS FOR THE FACILITY. | | | | | | THE PERMIT VALUE OF $15,000 IS UNDERVALUED FOR THE | | | SCOPE OF THE PROJECT. PERMIT VALUES SHALL INCLUDE BOTH | | | LABOR AND MATERIALS. SUBMIT A COPY OF THE SIGNED | | | CONTRACT INDICATING VALUE. | | | | | | THE UNDERGROUND FIRE MAIN (PERMIT #16020206) DOES NOT | | | SHOW A SUPPLY TO A FIRE PUMP AND NO REVISION WAS EVER | | | SUBMITTED SHOWING THIS CHANGE. THIS PERMIT HAS BEEN | | | CLOSED. A SEPARATE UNDERGROUND PERMIT WILL BE NEEDED BY | | | A FLORIDA STATE FIRE PROTECTION CONTRACTOR FOR THIS | | | UNDERGROUND WORK. | | | | | | THE FIRE SPRINKLER SYSTEM DESIGN CANNOT BE VERIFIED | | | WITHOUT THE FIRE PUMP AND PUMP HOUSE SUBMITTALS. WHAT | | | CONTRACTOR IS BUYING AND INSTALLING THE PUMP AND HOUSE? | | | IS THE ELECTRICAL SERVICE FOR THE FIRE PUMP, JOCKEY | | | PUMP AND CONTROLLERS PERMITTED? | | | | | | STANDPIPE PROVIDED FOR EXTERIOR EGRESS STAIR. | | | | | | CLOSELY SPACED SPRINKLER DEMAND NOT FOUND IN ANY | | | HYDRAULIC CALCULATIONS. | | | | | | SUBMIT THE SAFETY DATA SHEET JUSTIFYING SPRINKLER | | | PROTECTION IS NOT REQUIRED IN THE ELEVATOR PIT | | | UTILIZING NON-COMBUSTIBLE HYDRAULIC OIL. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-02 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-07-25 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2018-07-26 16:29:17 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-09-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-09-18 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-08-25 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2017-08-28 10:54:05 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2018-08-01 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-08-01 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-08-01 |
Time |
14:34 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-09-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-09-18 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-09-18 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2017-09-18 10:18:04 | PLEASE REFER TO FIRE COMMENTS. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
|