Plan Review Details - Permit 17081061
| Plan Review Stops For Permit 17081061 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-09-15 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-09-15 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-09-15 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-11-03 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-11-03 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-09-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-18 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-18 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2017-09-18 09:50:28 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. MORE DETAIL REQUIRED FOR RELOCATION OF STEAM | | | GENERATOR. IS THIS UNIT RATED TO BE INSTALLED IN A DAMP | | | LOCATION? HOW IS THE POWER SUPPLIED TO THE UNIT, WITH | | | CORD AND PLUG OR DIRECT CONNECTED (NO RECEPTACLE | | | PERMITTED IN SHOWER)? IS THE BENCH THIS IS LOCATED | | | UNDER COMPLETELY ENCLOSED SO THE STEAM UNIT WOULD NOT | | | ACTUALLY BE IN THE SHOWER? WHERE IS THE REQUIRED | | | DISCONNECT FOR THIS UNIT? PROVIDE RESPONSES AND SPEC | | | SHEET FOR UNIT. NEC 110.3, 406.9(C), 424.12(B), 424.19 | | | 2. PROVIDE FLOOR PLAN SHOWING SMOKE/CO ALARMS IN EACH | | | LOCATION REQUIRED PER CODE. SHOW ON PLAN ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC R314.3, FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-11-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-10-17 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-10-17 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2017-09-18 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-03 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-03 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2017-11-03 12:34:23 | SEPARATE PERMIT REQUIRED FPOR MECHANICAL ALTERATIONS. | | | CCOLE- 11/3/17 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-10-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-10-17 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-10-17 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2017-10-17 14:23:43 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17081061 | | | 10/17/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A SCOPE OF WORK FOR MECHANICAL WITH | | | CORRESPONDING DETAILS ON THE PLAN. CLARIFY IF ANY | | | ALTERATIONS TO THE EXISTING HVAC SYSTEMS ARE PROPOSED | | | FOR THE NEW BATHROOM SUCH AS NEW EXHAUST FAN AND VENT, | | | NEW AC DUCTS, DIFFUSER, OR GRILLS ETC. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-10-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2017-10-26 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2017-10-26 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2017-10-26 16:56:05 | 10/26/17 APPROVED BY PLUMBING, PUT BACK IN "27", LAC |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-09-18 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2017-09-18 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2017-09-18 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2017-09-18 14:07:44 | FAUCET IN MASTER VALVE SHALL HAVE A TEMPERED MIXING | | | VALVE. IF INTEGRAL PROVIDE SPECIFICATION OR LOCATION | | | WHERE IT WILL BE PLACED FBC P2724.1 | | | | | | SHOWER SHOWS A WEDI SYSTEM PLEASE PROVIDE MANUFACTURE | | | SPECIFICATIONS. PLEASE PROVIDE WHAT STANDARD OF TESTING | | | METHODS WAS USED FOR PRODUCT APPROVAL. FBC P2609.4 | | | | | | SHOWER SHOWS A STEAM GENERATOR PLEASE PROVIDE | | | MANUFACTURE SPECIFICATION. THE STEAM UNIT IS UNDER A | | | THE SHOWER SEAT. HOW IS THE STEAM ENTERING THE SHOWER? | | | PLEASE CLARIFY WHAT TYPE OF PROTECTION IS BEING USED | | | AND SHOW WHERE IT GOING IN THE SHOWER. FBC AMENDMENTS | | | 107.2.1 | | | | | | HAND HELD SHOWER MUST HAVE INTEGRAL VACUUM BREAKER FBC | | | P2902.4.2 | | | | | | LAVS SHOW WALL MOUNTED FAUCET TO FIXTURE AND REQUIRE | | | VALVES SERVING IT. PLEASE SHOW AND CLARIFY IF BEING | | | INSTALLED UNDER SINK. FBC P2903.9.3 | | | | | | LAY OUT ON PLAN NOT TO CODE, PLEASE PROVIDE AN | | | ISOMETRIC DIAGRAM. SHOWER EXCEEDS LENGTH ON TRAP AND | | | VENTING. DRAIN, WASTE AND VENT PIPE SIZING AND RISER | | | DIAGRAM FBC P3004, P3005 | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | 561-805-6720 | | | [email protected] | | | |
|
|
|