Plan Review Details - Permit 17081050
| Plan Review Stops For Permit 17081050 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-12-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-12-08 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-12-08 |
Time |
15:25 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-09-13 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-09-13 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2017-09-13 15:10:45 | ADDRESS F/D COMMENTS FOR AN ELECTRICAL PASS JLEAHY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-12-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-12-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-12-07 |
Time |
16:05 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-08-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-08-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-08-25 |
Time |
08:25 |
Sent To |
M |
|
| Notes |
| 2017-08-25 09:56:23 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THIS SUBMITTAL DOES NOT INCLUDE DETAILS OR EQUIPMENT | | | THAT IS TIED IN TO A DRY DOUBLE ACTION SPRINKLER | | | SYSTEM. | | | | | | PER NFPA 13, | | | | | | 8.15.10 ELECTRICAL EQUIPMENT. | | | 8.15.10.1 UNLESS THE REQUIREMENTS OF 8.15.10.3 ARE MET, | | | SPRINKLER PROTECTION SHALL BE REQUIRED IN ELECTRICAL | | | EQUIPMENT ROOMS. | | | 8.15.10.2 HOODS OR SHIELDS INSTALLED TO PROTECT | | | IMPORTANT ELECTRICAL EQUIPMENT FROM SPRINKLER DISCHARGE | | | SHALL BE NONCOMBUSTIBLE. | | | 8.15.10.3 SPRINKLERS SHALL NOT BE REQUIRED IN | | | ELECTRICAL EQUIPMENT ROOMS WHERE ALL OF THE FOLLOWING | | | CONDITIONS ARE MET: | | | (1) THE ROOM IS DEDICATED TO ELECTRICAL EQUIPMENT ONLY. | | | (2) ONLY DRY-TYPE ELECTRICAL EQUIPMENT IS USED. | | | (3) EQUIPMENT IS INSTALLED IN A 2-HOUR FIRE-RATED | | | ENCLOSURE INCLUDING PROTECTION FOR PENETRATIONS. | | | (4) NO COMBUSTIBLE STORAGE IS PERMITTED TO BE STORED IN | | | THE ROOM. | | | | | | | | | THE CONDITIONS OF 8.15.10.3 HAVE NOT BEEN MET. | | | SPRINKLER PERMIT 17060221 HAS BEEN DENIED BASED ON THE | | | SAME COMMENT. | | | | | | PLEASE COORDINATE WITH THE FIRE SPRINKLER CONTRACTOR | | | NAD PROVIDED FOR THE REQUIRED SYSTEM PROTECTION. | | | | | | | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
F |
Date |
2017-12-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-12-08 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-12-07 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2017-12-07 14:48:21 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-09-13 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-08-22 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2017-08-23 15:57:30 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2017-09-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-09-06 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-09-06 |
Time |
10:18 |
Sent To |
E |
|
| Notes |
|
|
|