| Plan Review Stops For Permit 17081015 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-10-23 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-10-23 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-10-23 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-29 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-29 |
Time |
17:55 |
Sent To |
|
|
| Notes |
| 2017-08-29 18:03:59 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. CALCULATIONS AND PLANS ARE FOR THE SIX STORY | | | BUILDING. THE ADDRESS ON THE APPLICATION, 2221, DOES | | | NOT CORRELATE WITH ANY OF THE BUILDING PERMIT | | | APPLICATIONS (2201, 2171, 2191 N AUSTRALIAN AVE). THE | | | SITE PLAN SHOWS A SIX STORY PROPOSED BUILDING AS 2221 N | | | AUSTRALIAN AVE. ON THE SITE PLAN, WHERE IS 2191 N | | | AUSTRALIAN AVE? IS ANOTHER SIX STORY PROPOSED? FBC 107, | | | SCOPE NOT CLEAR. | | | | | | SITE PLAN SHOWS "EXISTING" SIX STORY BUILDINGS WHICH DO | | | NOT APPEAR ON AERIALS, AND NO EVIDENCE OF PERMITS FOR | | | RECENT CONSTRUCTION OF SIX STORY BUILDINGS ON THIS | | | PARCEL. REVISE SITE PLAN (ON ALL AFFECTED PERMITS) OR | | | CLARIFY. | | | | | | 2. A COMPLETE SET OF PLANS WAS SUBMITTED. REMOVE | | | UNNECESSARY SHEETS, FBC 107. SEE REVIEW UNDER 17081012 | | | FOR DOCUMENTS TYPICALLY REQUIRED FOR FOUNDATION PERMIT. | | | | | | 3. CALCULATIONS INCLUDE OUTDATED CODE REFERENCES, | | | REVISE, FBC CH 35 (ASCE7-05, IBC 2009, ACI 2008, ETC.). | | | | | | 4. IF THIS IS A PROPOSED SIX STORY, THIS IS A THRESHOLD | | | BUILDING AND THE COMMENTS FOR 17081012 ARE APPLICABLE. | | | | | | SCOPE NOT CLEAR; COMPLETE REVIEW CANNOT BE DONE AT THIS | | | TIME. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-11-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-02 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-26 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2017-11-02 15:12:09 | FIRE REVIEW PASSED WITHOUTH FIRE PUMP, CHANGES | | | ELECTRICAL STATUS TO PASS. 11-2-17 | | 2017-10-26 14:12:29 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | PREVIOUS COMMENTS CORRECTED HAVE BEEN REMOVED AND NOTED | | | AS CORRECTED. REMAINING PREVIOUS COMMENTS HAVE THE | | | ORIGINAL COMMENT THAT STILL NEEDS CORRECTION WITH | | | FURTHER COMMENT IN (PARENTHESES). | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. PANEL H SHOWS A JOCKEY PUMP ON CIRCUIT 19, 21, 23. | | | IS THIS THE JOCKEY PUMP FOR THE FIRE PUMP SYSTEM? IF | | | SO, THIS CANNOT BE FEED FROM PANEL H. THE JOCKEY PUMP | | | SPECIFIED ON SHEET FP 2.0 IS NOT SHOWN ON RISER DIAGRAM | | | WITH FIRE PUMP. PROVIDE CORRECTION. NEC 215.5, | | | 695.4(B)(3); FBC 107.2.1 (JOCKEY PUMP AND ENTIRE FIRE | | | PUMP SYSTEM HAS BEEN REMOVED FROM PLANS. THIS WILL NEED | | | TO BE ON PLAN FOR THE FOUNDATION PERMIT BECAUSE THE | | | WIRING TO THE FIRE PUMP NEEDS TO MEET THE CODE | | | REQUIREMENTS OF NEC 695.6). | | | 5. FIRE PUMP SERVICE IS NOT LABELED AS ONE OF THE MAINS | | | FOR THE BUILDING. PROVIDE CORRECTION. NEC 230.2(E) | | | (ENTIRE FIRE PUMP SYSTEM HAS BEEN REMOVED FROM PLANS. | | | THIS WILL NEED TO BE ON PLAN FOR THE FOUNDATION PERMIT | | | BECAUSE THE WIRING TO THE FIRE PUMP NEEDS TO MEET THE | | | CODE REQUIREMENTS OF NEC 695.6). | | | 6. CORRECTED. | | | 7. PROVIDE DETAILS OF SECOND POWER SOURCE REQUIRED FOR | | | FIRE PUMP. NEC 695.3(B) (ENTIRE FIRE PUMP SYSTEM HAS | | | BEEN REMOVED FROM PLANS. THIS WILL NEED TO BE ON PLAN | | | FOR THE FOUNDATION PERMIT BECAUSE THE WIRING TO THE | | | FIRE PUMP NEEDS TO MEET THE CODE REQUIREMENTS OF NEC | | | 695.6 AND 695.14. SHOW LOCATION ON PLAN OF FIRE PUMP | | | ROOM AND THE ELECTRICAL FEED TO THAT ROOM FROM PRIMARY | | | AND SECONDARY SOURCE.) | | | 8. PROVIDE LOAD CALCULATION FOR FIRE PUMP CONTROLLER | | | AND ASSOCIATED EQUIPMENT TO VERIFY FEEDER, GROUNDING, | | | AND OVERCURRENT PROTECTION REQUIREMENTS. NEC 695.6 | | | (ENTIRE FIRE PUMP SYSTEM HAS BEEN REMOVED FROM PLANS. | | | THIS WILL NEED TO BE ON PLAN FOR THE FOUNDATION PERMIT | | | BECAUSE THE WIRING TO THE FIRE PUMP NEEDS TO MEET THE | | | CODE REQUIREMENTS OF NEC 695.6). | | | 9. PLAN STATES THAT THE LOCKED ROTOR CURRENT FOR THE | | | FIRE PUMP MOTOR IS 32.2 AMPS. ACCORDING TO TABLE | | | 430.251(B), THE LOCKED ROTOR CURRENT FOR A MOTOR THIS | | | SIZE SHOULD BE 179 AMPS. PROVIDE CORRECTION. NEC TABLE | | | 430.251(B); FBC 107.2.1 (ENTIRE FIRE PUMP SYSTEM HAS | | | BEEN REMOVED FROM PLANS. THIS WILL NEED TO BE ON PLAN | | | FOR THE FOUNDATION PERMIT BECAUSE THE WIRING TO THE | | | FIRE PUMP NEEDS TO MEET THE CODE REQUIREMENTS OF NEC | | | 695.6). | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-09-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-05 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-05 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2017-09-05 15:53:37 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SEE BUILDING PLAN REVIEW COMMENTS IN REFERENCE TO | | | ADDRESS ON PLANS. PROVIDE CORRECTION AS NEEDED ON | | | PLANS. FBC 107.2.1 | | | 2. SHEET E-8 SHOWS 7 SETS OF 750 KCMIL CU FOR SERVICE | | | FEEDERS, WHILE SHEET E-6 SHOWS 7 SETS OF 600 KCMIL CU. | | | CORRECT DISCREPANCY. FBC 107.2.1 | | | 3. LOAD CALCULATION FOR MDP SHOWS SEVERAL DIFFERENT | | | CALCULATIONS (ONE STORY, TWO STORY, ETC.). PROVIDE LOAD | | | CALCULATION RELATED TO THIS PERMIT ONLY FOR THE SIX | | | STORY BUILDING. REMOVE ALL OTHER UNRELATED INFORMATION. | | | ADDITIONALLY, THE LOAD VA SHOWN FOR THE 1 BEDROOM UNIT | | | IS THE SAME AS FOR THE 2 BEDROOM UNIT. LOAD CALCULATION | | | FOR PANEL H IS DIFFERENT THAN LISTED IN PANEL SCHEDULE. | | | PROVIDE CORRECTIONS. NEC 220, 220.84, 215.2, 408.30; | | | FBC 107.2.1 | | | 4. PANEL H SHOWS A JOCKEY PUMP ON CIRCUIT 19, 21, 23. | | | IS THIS THE JOCKEY PUMP FOR THE FIRE PUMP SYSTEM? IF | | | SO, THIS CANNOT BE FEED FROM PANEL H. THE JOCKEY PUMP | | | SPECIFIED ON SHEET FP 2.0 IS NOT SHOWN ON RISER DIAGRAM | | | WITH FIRE PUMP. PROVIDE CORRECTION. NEC 215.5, | | | 695.4(B)(3); FBC 107.2.1 | | | 5. FIRE PUMP SERVICE IS NOT LABELED AS ONE OF THE MAINS | | | FOR THE BUILDING. PROVIDE CORRECTION. NEC 230.2(E) | | | 6. PANEL H LOAD CALCULATION STATES THAT THE FIRST 10K | | | VA ARE AT 100%. HOWEVER, THE LOAD SHOWN IS 4320 VA, NOT | | | 10,000. PANEL H1 LOAD CALCULATION IS SIMILARLY WRONG. | | | PROVIDE CORRECTION. NEC 220.44 | | | 7. PROVIDE DETAILS OF SECOND POWER SOURCE REQUIRED FOR | | | FIRE PUMP. NEC 695.3(B) | | | 8. PROVIDE LOAD CALCULATION FOR FIRE PUMP CONTROLLER | | | AND ASSOCIATED EQUIPMENT TO VERIFY FEEDER, GROUNDING, | | | AND OVERCURRENT PROTECTION REQUIREMENTS. NEC 695.6 | | | 9. PLAN STATES THAT THE LOCKED ROTOR CURRENT FOR THE | | | FIRE PUMP MOTOR IS 32.2 AMPS. ACCORDING TO TABLE | | | 430.251(B), THE LOCKED ROTOR CURRENT FOR A MOTOR THIS | | | SIZE SHOULD BE 179 AMPS. PROVIDE CORRECTION. NEC TABLE | | | 430.251(B); FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2017-10-25 |
|
|
Cont ID |
|
| Sent By |
squinone |
Date |
2017-10-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
squinone |
Date |
2017-10-25 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-11-02 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-11-02 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-11-02 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-08-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-08-25 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-08-25 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2017-08-25 13:07:29 | FOUNDATION ONLY | | | | | | PER NFPA 241 SECTION 8.7.2.3, WHERE UNDERGROUND WATER | | | MAINS AND HYDRANTS ARE TO BE PROVIDED, THEY SHALL BE | | | INSTALLED, COMPLETED, AND IN SERVICE PRIOR TO VERTICAL | | | CONSTRUCTION WORK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-11-03 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-11-01 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2017-11-02 15:26:09 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-11-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-11-02 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-16 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-10-04 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-10-04 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-08-22 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-08-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-29 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-29 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2017-08-29 08:48:55 | PER EMAIL DATED 8/29/17 FROM WILLIE SWOPE, PALM BEACH | | | COUNTY IMPACT FEE OFFICE, IMPACT FEES MAY BE PAID | | | BEFORE (VERTICAL) BUILDING PERMIT; OK TO ISSUE | | | FOUNDATION PERMITS WITHOUT PALM BEACH COUNTY IMPACT FEE | | | COLLECTION. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-10-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-10-23 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-10-23 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-11-03 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-11-03 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-10-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-10-30 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-10-30 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2017-10-30 09:00:27 | 1) ONE SET OF THE SUBMITTED PLANS HAS PLUMBING SHEETS | | | THAT DO NOT BEAR THE SEAL OF THE DESIGN ENGINEER OF | | | RECORD. COMPLY WITH F.A.C. RULE 61G15-23.001. REFER TO | | | SHEETS P-1, P-3, P-5, P-6 & P-10. | | | 2) ONE SET OF THE SUBMITTED PLANS DOES NOT CONTAIN ANY | | | PLUMBING DRAWINGS. SUBMIT THE PLUMBING DRAWINGS FOR | | | REVIEW. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-09-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-06 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-06 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2017-09-06 17:02:15 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. TRAP PRIMER VALVES ARE REQUIRED ON ALL FLOOR DRAINS | | | TRAP GUARDS ARE NOT APPROVED. PER FBC PL 1002.4 TRAP | | | SEALS. | | | EACH FIXTURE TRAP SHALL HAVE A LIQUID SEAL OF NOT LESS | | | THAN 2 INCHES (51 MM) AND NOT MORE THAN 4 INCHES (102 | | | MM), OR DEEPER FOR SPECIAL DESIGNS RELATING TO | | | ACCESSIBLE FIXTURES. WHERE A TRAP SEAL IS SUBJECT TO | | | LOSS BY EVAPORATION, A TRAP SEAL PRIMER VALVE SHALL BE | | | INSTALLED. TRAP SEAL PRIMER VALVES SHALL CONNECT TO THE | | | TRAP AT A POINT ABOVE THE LEVEL OF THE TRAP SEAL. A | | | TRAP SEAL PRIMER VALVE SHALL CONFORM TO ASSE 1018 OR | | | ASSE 1044. | | | | | | 2. THERE SHALL BE A CLEANOUT NEAR THE JUNCTION OF THE | | | BUILDING DRAIN AND THE BUILDING SEWER. PER FBC PL | | | 708.3.5 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2017-10-23 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-10-23 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-10-23 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2017-10-23 14:16:16 | RECEIVED SPECIAL INSPECTOR AGREEMENT. | | | GFA PAUL H DANFOURTH PE, SI | | | NOEL WOODALL INSPECTOR BN 2505 | | | CARL D. CROOK INSPECTOR BN 3909 |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2017-08-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-29 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-29 |
Time |
18:16 |
Sent To |
|
|
| Notes |
| 2017-08-29 18:16:42 | SEE 17081012 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-11-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-11-01 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-09-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-09-19 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|