Plan Review Details - Permit 17080847
Plan Review Stops For Permit 17080847
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-09-28 Cont ID  
Sent By jwitmer Date 2017-09-28 Time 06:14 Rev Time 0.00
Received By jwitmer Date 2017-09-28 Time 06:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-08-24 Cont ID  
Sent By jwitmer Date 2017-08-24 Time 06:30 Rev Time  
Received By jwitmer Date 2017-08-24 Time 05:59 Sent To  
Notes
2017-08-24 06:18:032014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17080847
 ADD: 600 S. DIXIE HWY.
 CONT: J & G CARPENTRY INC.
 TEL: 561-855-4052
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. AUGUST 24, 2017
 ACTION: DENIED
 BUILDING BUILT IN 2006/ FAIR HOUSING
  
 1) CERTIFICATION BY CONTRACTOR. THE CONTRACTOR
 (QUALIFIER) THAT CREATED / DRAWN THE SET OF PLANS WILL
 NEED TO IDENTIFY THEMSELVES AS THE AUTHOR OF THE PLANS.
 PLEASE PRINT YOUR NAME, SIGN YOUR NAME AND LICENSE
 NUMBER FOR THE TRADE YOU ARE LICENSED IN AND PLANS
 DRAWN. 107.3.4.3 CERTIFICATION BY CONTRACTOR.
  
 2) NEW KITCHEN FLOOR WITH WHISPER MAT FOR TILE.
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 2A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 2B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-08-29 Cont ID  
Sent By jpearson Date 2017-08-29 Time 07:50 Rev Time 0.00
Received By jpearson Date 2017-08-29 Time 07:50 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-09-25 Cont ID  
Sent By pleduc Date 2017-09-25 Time   Rev Time 0.00
Received By pleduc Date 2017-09-25 Time 12:35 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-08-22 Cont ID  
Sent By pleduc Date 2017-08-22 Time   Rev Time 0.00
Received By pleduc Date 2017-08-22 Time 07:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-10-03 Cont ID  
Sent By gjohnson Date 2017-10-03 Time 15:05 Rev Time 0.00
Received By gjohnson Date 2017-09-20 Time 14:07 Sent To  
Notes
2017-09-22 14:07:41B07

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-09-13 Cont ID  
Sent By lmarchan Date 2017-09-13 Time 13:11 Rev Time 0.00
Received By lmarchan Date 2017-08-17 Time 12:47 Sent To  
Notes
2017-08-18 12:47:06B16

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2017-08-24 Cont ID  
Sent By jwitmer Date 2017-08-24 Time 06:30 Rev Time  
Received By jwitmer Date 2017-08-24 Time 05:59 Sent To  
Notes
2017-08-24 06:17:47NO CHANGE IN OCCUPANCY.

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-10-03 Cont ID  
Sent By gjohnson Date 2017-10-03 Time 15:05 Rev Time 0.00
Received By gjohnson Date 2017-10-03 Time 15:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-08-28 Cont ID  
Sent By gjohnson Date 2017-08-28 Time 16:23 Rev Time 0.00
Received By gjohnson Date 2017-08-28 Time 16:22 Sent To  
Notes
***NONE***