| Plan Review Stops For Permit 17080838 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-10-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-10-31 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-10-31 |
Time |
08:48 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-09-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-09-19 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-09-19 |
Time |
18:57 |
Sent To |
G |
|
| Notes |
| 2017-09-19 18:57:38 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE GENERATOR IS LOCATED IN EXPOSURE D WITH A 170 | | | MPH VULT WIND SPEED. BASED ON FBC-R 301.2.1, THE | | | REQUIRED PRESSURE IS 49.9 PSF. THE ENGINEERING THAT WAS | | | SUBMITTED HAS AN ALLOWABLE PRESSURE OF 40.38 PSF. | | | SUBMIT ENGINEERING THAT HAS AN ALLOWABLE PRESSURE OF | | | 49.9 PSF OR HIGHER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-08-25 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-08-25 |
Time |
06:51 |
Sent To |
E |
|
| Notes |
| 2017-08-25 07:24:22 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE GENERATOR PAD DRAWINGS ARE REQUIRED TO HAVE THE | | | FLORIDA ENGINEER'S SEAL AND ORIGINAL HANDWRITTEN | | | SIGNATURE, COPIES OR OTHER FACSIMILES ARE NOT | | | ACCEPTABLE. FAC 61G15 - 23.002 DIGITAL SIGNATURES ARE | | | ONLY ACCEPTABLE FOR ELECTRONICALLY TRANSMITTED PLANS | | | AND DOCUMENTS. RALPH H. WILSON'S LICENSE HAS BEEN | | | REVOKED PER DBPR. | | | | | | 2) PROVIDE MANUFACTURER'S DOCUMENTS WITH THE MODEL | | | NUMBER OF THE GENERATOR. THE GENERATOR MODEL NUMBER | | | NEEDS TO BE LISTED ONE THE PAD DOCUMENTS. FBC 107.2.1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-09-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-09-19 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-09-19 |
Time |
12:36 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-08-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-08-28 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-08-28 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2017-08-28 16:08:53 | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | | NFPA 70 2011 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | SMALL PANEL OFF TRANSFER SWITCH HAS #3S FEEDING IT HOW | | | IS THIS PROTECTED? |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2017-09-22 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-09-22 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-09-22 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-08-24 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-08-24 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-08-24 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2017-08-24 15:39:43 | 1) P.E SIGNATURE MUST BE WET, NO PHOTO COPIES ARE | | | ALLOWED | | | | | | 2) P.E RONALD WILSON # 9710 LICENSE IS REVOKED PER | | | MYFLORIDA.COM AS OF 02/28/2017 | | | | | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2014 FGC SEC.410.1 | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-08-24 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2017-08-24 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2017-08-24 |
Time |
08:49 |
Sent To |
G |
|
| Notes |
| 2017-08-24 08:52:45 | 8/24/2017 - NO MATERIAL AFFECT TO THE HISTORIC PROPERTY | | | - MEETS ZONING REQUIREMENTS. DLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-10-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-10-31 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-10-25 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2017-10-27 09:48:44 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-10-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-10-27 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-09-05 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2017-09-06 14:25:03 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-08-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-08-28 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-08-17 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2017-08-18 12:43:54 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-08-22 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-08-22 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-08-21 |
Time |
17:36 |
Sent To |
HIST |
|
| Notes |
|
|