Plan Review Details - Permit 17080643
Plan Review Stops For Permit 17080643
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-08-18 Cont ID  
Sent By jwitmer Date 2017-08-18 Time 07:44 Rev Time 0.00
Received By jwitmer Date 2017-08-18 Time 07:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-09-06 Cont ID  
Sent By jpearson Date 2017-09-06 Time 07:08 Rev Time 0.00
Received By jpearson Date 2017-09-06 Time 07:08 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-08-16 Cont ID  
Sent By jpearson Date 2017-08-16 Time 11:09 Rev Time 0.00
Received By jpearson Date 2017-08-16 Time 11:08 Sent To  
Notes
2017-08-16 11:08:54CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE SHOW WINDOW OUTLET PER CODE. NEC 210.62
 2. PROVIDE AUTOMATIC CONTROL FOR SIGN AND SHOW WINDOW
 LIGHTING PER FBC ENERGY CODE. FBC C405.2.4
 3. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1:
 8.4.2. FBC C405.7.1
 4. PLAN SHOWS CIRCUIT A-26 AS THE SIGN CIRCUIT, BUT THE
 PANEL SCHEDULE SHOWS CIRCUIT A-13 AS THE SIGN CIRCUIT.
 CLARIFY AND/OR CORRECT. FBC 107.2.1
 5. PANEL SCHEDULE SHOWS CIRCUIT A-5 FEEDING "DIM HH
 THERAPY LIGHTING". I DO NOT SEE THIS CIRCUIT OR THE
 LIGHTING ON THE PLAN. CLARIFY AND/OR CORRECT. FBC
 107.2.1
 6. PROVIDE THE ADDITIONAL LIGHTING CONTROLS STIPULATED
 IN THE FBC ENERGY CODE. MANY AREAS DO NOT SHOW ANY
 AUTOMATIC CONTROL. FBC C405.2.2, 405.2.2.2
 7. PROVIDE INTERIOR LIGHTING CALCULATION, INCLUDING NEW
 FIXTURES ADDED, SHOWING COMPLIANCE WITH THE FBC ENERGY
 CODE FOR THE SPACE. FBC C405.5
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2017-09-15 Time   Rev Time 0.00
Received By lmarchan Date 2017-09-01 Time 13:38 Sent To  
Notes
2017-09-05 13:39:09RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2017-08-21 Time   Rev Time 0.00
Received By cpuell Date 2017-08-14 Time 10:12 Sent To  
Notes
2017-08-15 10:13:53B03

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-09-15 Cont ID  
Sent By ccole Date 2017-09-15 Time 07:41 Rev Time 0.00
Received By ccole Date 2017-09-15 Time 07:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-08-21 Cont ID  
Sent By ccole Date 2017-08-21 Time 17:23 Rev Time 0.00
Received By ccole Date 2017-08-21 Time 16:03 Sent To  
Notes
2017-08-21 17:32:041ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17080643
 8/21/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE FLEX DUCT SIZES SHOWN ON THE PLANS APPEAR TO BE
 OVERSIZED FOR THE AMOUNT OF AIR BEING SUPPLIED. PLEASE
 VERIFY THAT THESE SIZES- 18" FOR 345 CFMS, 12" FOR 140
 CFMS ETC. ARE CORRECT.
  
 2) PROVIDE A DAMPER FOR THE OUTSIDE AIR INTAKE DUCT
 THAT WILL AUTOMATICALLY SHUT WHEN THE SYSTEM OR SPACE
 IS NOT IN USE- SECTION C403.2.4.4 FBC-14 ENERGY
 CONSERVATION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-08-21 Cont ID  
Sent By thunt Date 2017-08-21 Time 15:05 Rev Time 0.00
Received By thunt Date 2017-08-21 Time 14:06 Sent To  
Notes
***NONE***