| Plan Review Stops For Permit 17080637 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-11-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-11-17 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-11-17 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2017-11-17 15:06:49 | 11/16/17 REVISED PLANS SUBMITTED. JG. | | | | | | | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: | | | A) EXTERIOR SWING DOORS AS SHOWN ON PLANS. NOA | | | 01-0122.09 SUBMITTED EXPIRED ON APRIL 25, 2007. NEED | | | CURRENT NOA. | | | 2- ARCHITECT OF RECORD TO APPROVE IN WRITING ABOVE | | | PRODUCT APPROVAL. | | | 3- SPECIFY ALL FRAMING MEMBERS AND CONNECTORS ON THE | | | TYP. EXTERIOR WALL FRAMING DETAIL ON SHEET A-4. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-11-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-11-14 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-11-14 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2017-11-14 12:17:23 | RESIDENTIAL (R3) ALTERATION THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- CLEARLY SPECIFY TYPE AND SIZE OF EXISTING BEDROOM | | | WINDOWS AND TYPE AND SIZE OF PROPOSED BEDROOM WINDOWS | | | TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS. SEC. | | | 704 OF FBC-EXISTING BUILDING, 5TH EDITION (2014). | | | RESPONSE: REPEAT COMMENT. SIZES OF WINDOWS SHOWN ON THE | | | FLOOR PLAN ON SHEET A-2 DON'T MATCH SIZES SHOWN ON THE | | | EXTERIOR ELEVATIONS ON SHEET A-3. REVISE AS REQUIRED TO | | | MATCH. MASTER BEDROOM AND BEDROOM #2 WINDOW SIZE SHOWN | | | ON PLAN DON'T MATCH THOSE SHOWN ON THE ELEVATIONS. | | | NOTE: THE ONLY WINDOW SIZES THAT COMPLY WITH ALL THE | | | EGRESS REQUIREMENTS ARE THE 36" X 63" SINGLE HUNG | | | WINDOW SPECIFIED FOR BEDROOM #2 ON THE EAST ELEVATION | | | AND THE 36" X 72" SINGLE HUNG WINDOWS SPECIFIED FOR THE | | | MASTER BEDROOM. THE OTHER WINDOW SIZES DON'T SEEM TO | | | COMPLY WITH THE MIN. 24" CLEAR HEIGHT OPENING. REVISE | | | PLANS AS REQUIRED. | | | | | | NOTE: ARCHITECT MAY BE CHARGED 4 TIMES THE PLAN REVIEW | | | FEE AS REQUIRED BY FLORIDA STATUTE 553.80(2)(B) FOR | | | MULTIPLE PLAN REVIEW REJECTIONS. | | | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | A) EXTERIOR SWING DOORS AS SHOWN ON PLANS. NOA | | | 01-0122.09 SUBMITTED EXPIRED ON APRIL 25, 2007. NEED | | | CURRENT NOA. | | | RESPONSE: NO PRODUCT APPROVAL SUBMITTED AT THIS TIME. | | | NOTE: THIS MAY BE SUBMITTED AFTER PERMIT IS ISSUED, BUT | | | BEFORE INSPECTIONS TO AVOID CONFLICT/DELAYS. | | | | | | 3- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | (INCLUDING THE ONES THAT WERE ALREADY SUBMITTED) AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | RESPONSE. REPEAT COMMENT. | | | | | | 4- NEW SHEET T-1: | | | A) THE CONSTRUCTION TYPE SPECIFIED UNDER THE LOCATION | | | MAP IS INCORRECT. THIS IS A TYPE VB CONSTRUCTION NOT | | | TYPE III. SEC. 602 FBC-5TH EDITION (2014). | | | RESPONSE: REPEAT COMMENT. | | | | | | B) AS REQUESTED ON PREVIOUS CHECKLIST THE SCOPE OF WORK | | | WAS REVISED TO SAY ALTERATION LEVEL 3 INSTEAD OF LEVEL | | | 2. THIS WAS DONE, BUT THERE IS STILL REFERENCE FOR | | | ALTERATION LEVEL 2 BELOW THE FRONT ELEVATION SHOWN ON | | | THE UPPER RIGHT CORNER OF THIS DRAWING. CLARIFY/REVISE | | | AS REQUIRED TO MATCH THE SCOPE OF WORK. SEC. 107.2.1 | | | CITY AMENDMENTS. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS | | | FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-10-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-10-19 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-10-18 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2017-10-18 15:50:29 | RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- THERE ARE TWO STRUCTURES SHOWN ON PLANS SUBMITTED. | | | THE MAIN HOUSE AND THE REAR STRUCTURE. NEED TO SUBMIT A | | | PERMIT APPLICATION FOR EACH STRUCTURE. 105.1 AND SEC. | | | 107.2.1.4 CITY AMENDMENTS. | | | RESPONSE: REVISED PLANS SPECIFY THAT REAR STRUCTURE IS | | | GOING TO BE DEMOLISHED. NEED TO SUBMIT SEPARATE PERMIT | | | APPLICATION FOR THE DEMOLITION OF THE REAR BUILDING. | | | COORDINATE WITH THE HISTORIC PLANNER. | | | | | | 2- CLEARLY SPECIFY TYPE AND SIZE OF EXISTING BEDROOM | | | WINDOWS AND TYPE AND SIZE OF PROPOSED BEDROOM WINDOWS | | | TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS. SEC. | | | 704 OF FBC-EXISTING BUILDING, 5TH EDITION (2014). | | | RESPONSE: SIZES OF WINDOWS SHOWN ON THE FLOOR PLAN ON | | | SHEET A-2 DON'T MATCH SIZES SHOWN ON THE EXTERIOR | | | ELEVATIONS ON SHEET A-3. REVISE AS REQUIRED TO MATCH. | | | ALSO, TO AVOID CONFLICTS, PLEASE USE THE SAME FORMAT TO | | | SPECIFY SIZE OF WINDOWS (FOR EXAMPLE 37"W X 63"H SINGLE | | | HUNG WINDOWS). NOTE: THERE ARE SOME BEDROOM WINDOWS | | | THAT DON'T SEEM TO COMPLY WITH THE EGRESS REQUIREMENTS. | | | ALL BEDROOMS NEED TO COMPLY WITH THE EGRESS | | | REQUIREMENTS. CLEARLY SHOW THE ACTUAL SIZE OF THE | | | BEDROOM WINDOWS THAT COMPLY WITH THE EGRESS | | | REQUIREMENTS SPECIFIED ON THE EGRESS WINDOWS NOTES ON | | | SHEET A-2 AND A-3. SEE PGT SINGLE HUNG PRODUCT APPROVAL | | | SUBMITTED FOR STANDARD SIZES. | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | A) EXTERIOR SWING DOORS AS SHOWN ON PLANS. NOA | | | 01-0122.09 SUBMITTED EXPIRED ON APRIL 25, 2007. NEED | | | CURRENT NOA. | | | RESPONSE: REPEAT COMMENT. | | | | | | B) CLARIFY IF NEW ROOFING IS GOING TO BE INSTALLED OR | | | NOT. IF SO, THEN NEED TO PROVIDE PRODUCT APPROVAL. AND, | | | CLEARLY MARK APPROVED ASSEMBLY TO BE INSTALLED AND | | | PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF | | | REQUIRED. | | | RESPONSE: REPEAT COMMENT. | | | | | | 4- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | (INCLUDING THE ONES THAT WERE ALREADY SUBMITTED) AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | RESPONSE. REPEAT COMMENT. | | | | | | 5- NEW SHEET T-1: | | | A) ALTERATION LEVEL WAS CHANGED FROM LEVEL 3 TO LEVEL | | | 2. THE WORK AREA EXCEEDS 50 PERCENT OF THE AREA OF THE | | | BUILDING. THEREFORE, THE ALTERATION LEVEL IS 3. REVISE | | | AS REQUIRED. SEC. 505 FBC-EXISTING BUILDING, 5TH | | | EDITION (2014). | | | | | | B) THE CONSTRUCTION TYPE SPECIFIED UNDER SITE DATA AND | | | UNDER THE LOCATION MAP IS INCORRECT. THIS IS A TYPE VB | | | CONSTRUCTION NOT TYPE III. SEC. 602 FBC-5TH EDITION | | | (2014). | | | | | | 6- SHEET A-4: | | | A) POST BASE CONNECTOR "A1" IS NOT CLEAR. WHAT'S "HBC | | | POST BASE"? CLEARLY SPECIFY SPECIFIC POST BASE MODEL TO | | | BE USED AND PROVIDE CURRENT FLORIDA PRODUCT APPROVAL | | | NUMBER. | | | SEC. R301.1 FBC-RESIDENTIAL. | | | | | | B) STUCCO ON WOOD FRAMED BUILDINGS REQUIRES 2 WATER | | | RESISTIVE BARRIERS AS REQUIRED BY SEC. R703.6.3 | | | FBC-RESIDENTIAL. REVISE SPECIFICATIONS ON THE TYPICAL | | | WALL SECTION AS REQUIRED. | | | | | | C) CLARIFY IF NEW ROOFING IS GOING TO BE INSTALLED OR | | | NOT. IF SO, THEN NEED TO PROVIDE PRODUCT APPROVAL. FAC | | | 61G20-3.001. CLARIFY WHY BOTH WALL SECTIONS PROVIDE | | | SPECIFICATIONS FOR THE FLAT ROOF. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | D) SPECIFY ALL FRAMING MEMBERS AND CONNECTORS ON THE | | | TYPICAL EXTERIOR WALL FRAMING DETAIL. SEC. R301.1 | | | FBC-RESIDENTIAL. | | | | | | 7- BASED ON ALL THE SCOPE OF WORK SHOWN ON PLANS | | | (INCLUDING ALL THE MECHANICAL AND ELECTRICAL WORK SHOWN | | | ON PLANS) THE VALUE DECLARED IN THE PERMIT APPLICATION | | | IS TOO LOW. VALUE TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. CONTRACTOR TO UPDATE VALUE AND ADD THE FEES | | | FOR THE DESIGN PROFESSIONAL. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS | | | FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-09-13 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-09-13 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2017-09-13 11:28:38 | RESIDENTIAL (R3) ALTERATIONS BUILDING REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- THERE ARE TWO STRUCTURES SHOWN ON PLANS SUBMITTED. | | | THE MAIN HOUSE AND THE REAR STRUCTURE. NEED TO SUBMIT A | | | PERMIT APPLICATION FOR EACH STRUCTURE. SAME SET OF | | | PLANS CAN BE USED FOR BOTH STRUCTURES. THERE IS NO NEED | | | TO SUBMIT SEPARATE PLANS FOR EACH STRUCTURE. SEC. 105.1 | | | AND SEC. 107.2.1.4 CITY AMENDMENTS. NOTE: THE SEPARATE | | | PERMITS ARE FOR PROPER INSPECTIONS OF EACH STRUCTURE | | | AND FOR THE PROPER RECORD RETENTION. | | | | | | 2- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG) FOR IMPACT FEES ASSESSMENT. BRING | | | BACK COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF | | | FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE | | | UNIFIED LAND DEVELOPMENT CODE. | | | NOTE: THIS IS FOR THE CONVERSION OF THE GARAGE TO | | | HABITABLE AREA. | | | | | | 3- SHEET CS-1: | | | A) REAR STRUCTURE SHOWN ON THE SITE PLAN STATES "EXIST. | | | ONE STORY PLAYROOM TO BE REMODELED 626 S.F.". ACCORDING | | | TO CITY RECORDS THE REAR STRUCTURE IS A GARAGE AND | | | HABITABLE AREA. THERE ARE NO CITY RECORDS SHOWING ANY | | | PERMIT FOR THE PLAYROOM. REVISE PLANS AS REQUIRED. SHOW | | | ALL WORK AS BEING PROPOSED NOT EXISTING. SAME COMMENT | | | APPLIES TO FLOOR PLAN ON SHEET A-1 SEC. 105.1 AND SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | B) CLARIFY WHAT DOES "IMPORTANCE FACTOR = 1.21" | | | SPECIFIED ON THE DESIGN LOAD SCHEDULE STANDS FOR? . | | | DOES ARCHITECT MEANS RISK CATEGORY?. IF SO, SEE TABLE | | | 1604.5 FBC-BUILDING, 5TH EDITION (2014) FOR THE CORRECT | | | RISK CATEGORY. REVISE AS REQUIRED. | | | | | | C) CLARIFY THE NOTE AT THE BOTTOM OF THE DESIGN LOAD | | | SCHEDULE. WHY THE WINDOW AND DOOR MANUFACTURERS SHALL | | | MULTIPLY THE DOORS AND WINDOWS GIVEN DESIGN PRESSURES | | | BY THE APPROPRIATE FACTORS TO OBTAIN TEST PRESSURES? | | | THIS IS NOT CLEAR. DOORS AND WINDOWS NEED TO MEET THE | | | DESIGN PRESSURES THAT ARE CALCULATED BY THE ARCHITECT | | | OF RECORD. THERE IS NO NEED TO OBTAIN THE TEST | | | PRESSURES. THESE PRESSURES ARE USUALLY GIVEN IN THE | | | PRODUCT APPROVAL. CLARIFY/REVISE AS REQUIRED. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | D) PROVIDE CORRECT SCOPE OF WORK AND ALTERATION LEVEL | | | FOR THE REAR STRUCTURE. THIS IS NOT JUST ALTERATION | | | LEVEL 3. THIS IS A "CHANGE OF USE" OF GARAGE TO | | | HABITABLE SPACE. REVISE AS REQUIRED. SEC. 506 | | | FBC-EXISTING BUILDING, 5TH EDITION (2014). | | | | | | 4- SHEET A-1: | | | A) PROVIDE COMPLETE DETAIL AND SPECIFICATIONS FOR THE | | | SECTIONS OF THE EXTERIOR WALLS TO BE REPAIRED, | | | INCLUDING ALL FRAMING MEMBERS AND CONNECTORS. SEC. | | | R301.1 FBC-RESIDENTIAL.5TH EDITION (2014). | | | | | | B) CLEARLY SPECIFY TYPE AND SIZE OF EXISTING BEDROOM | | | WINDOWS AND TYPE AND SIZE OF PROPOSED BEDROOM WINDOWS | | | TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS OF | | | SEC. 704 OF FBC-EXISTING BUILDING, 5TH EDITION (2014). | | | | | | C) ARCHITECT TO PROVIDE SPECIFICATIONS SHOWING | | | COMPLIANCE WITH THE REQUIRED HEATING ON EACH ROOM OF | | | THE PROPOSED PLAYROOM CONVERSION. SEC. R303.9 | | | FBC-RESIDENTIAL. | | | | | | 5- SPECIFY ALL FRAMING MEMBERS AND CONNECTORS ON ALL | | | EXTERIOR WALL FRAMING DETAILS ON SHEET A-3. SEC. R301.1 | | | FBC-RESIDENTIAL. | | | | | | 6- CLARIFY IF SCOPE OF WORK INCLUDES RE-ROOFING. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | A) FLAT ROOF IF RE-ROOFING IS PART OF THE SCOPE OF | | | WORK. COORDINATE WITH ITEM #6 ABOVE. CLEARLY IDENTIFY | | | FLAT ROOF ASSEMBLY TO BE INSTALLED AND PROVIDE SIGNED | | | AND SEALED RAS 117 CALCULATIONS IF SELECTED ASSEMBLY | | | DOESN'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. | | | | | | B) GLASS BLOCK AS SHOWN ON PLANS. NOTE: COORDINATE WITH | | | HISTORIC PLANER IF GLASS BLOCK IS ALLOWED. | | | | | | C) INSULATED EXTERIOR SWING DOOR. JELD-WEN NOA | | | 01-0122.09 SUBMITTED EXPIRED ON APRIL 25, 2007. NEED | | | CURRENT NOA. | | | | | | D) SLIDING WINDOWS A SHOWN ON PLANS. | | | | | | E) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS | | | AND DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL | | | COVER PAGE AND PAGE SHOWING THE SPECIFIC CONNECTOR OR | | | ARCHITECT OF RECORD TO LIST THE CURRENT FLORIDA PRODUCT | | | APPROVAL NUMBER NEXT TO EACH SPECIFIED CONNECTOR. | | | | | | 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS | | | FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-10-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-27 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-27 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-08-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-30 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-30 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2017-08-30 11:47:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW. PROVIDE PANEL | | | SCHEDULE INDICATING ANY NEW OR ALTERED CIRCUITS, THE | | | WIRE AND BREAKER SIZE FOR THESE CIRCUITS, AND AFCI OR | | | GFCI PROTECTION WHERE APPLICABLE TO COMPLY WITH CODE. | | | NEC 210.8, 210.12, 215.5, 408.4; FBC RE3706.2, RE3902FS | | | 471.003(2)(H); 471.025; FBC 107.2.1, 107.3.5 | | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO INTERIOR | | | PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM | | | BONDING TERMINATION POINT. NEC 215.5, 230, 250.50, | | | 250.94, 408.30 FBC RE3706.1, RE3608.1, RE3609.3; FBC | | | 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-11-28 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-11-28 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2017-11-14 17:46:16 | NEW DRAWINGS SUBMITTED. JG. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-10-11 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-10-11 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-10-11 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2017-10-11 14:50:48 | SEPERATE PERMIT REQUIRED FOR DEMO OF REAR BUILDING |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-08-25 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-08-25 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-08-25 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2017-08-25 09:51:13 | FLOOR PLANS AND ELEVATIONS DO NOT MATCH FOR WINDOW | | | STYLES/OPENINGS. NO NEW GLASS BLOCK PERMITTED, ALL | | | WINDOWS TO BE SH, VERTICALLY ORIENTED WITH RAISED | | | EXTERIOR MUNTINS. | | | | | | QUESTIONS, CONTACT: | | | | | | FRIEDERIKE MITTNER, CITY HISTORIC PRESERVATION PLANNER | | | (561) 822-1457 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-11-28 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-11-08 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-10-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-27 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-02 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-09-13 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-14 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2017-10-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-10-18 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-10-18 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2017-10-18 16:47:21 | ACCORDING TO PLANS REAR STRUCTURE IS GOING TO BE | | | DEMOLISHED. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-09-13 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-09-13 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2017-09-13 11:34:58 | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG) FOR IMPACT FEES ASSESSMENT. BRING | | | BACK COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF | | | FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE | | | UNIFIED LAND DEVELOPMENT CODE. | | | NOTE: THIS IS FOR THE CONVERSION OF THE GARAGE TO | | | HABITABLE AREA. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-10-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-10-26 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-10-26 |
Time |
13:03 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2017-10-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-10-19 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-19 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2017-10-27 12:44:37 | ADDED "N" STATUS TO THIS STEP BECAUSE IT WAS ORIGINALLY | | | LEFT BLANK AND IT HAS BEEN APPROVED AT A LATER DATE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-09-13 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-09-13 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2017-09-13 16:13:17 | NO MECHANICAL WORK SHOWN. ANY MECHANICAL WORK REQUIRES | | | COMPLETE INFORMATION UNDER SEPARATE PERMIT. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2017-11-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-11-17 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-11-17 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2017-11-17 16:03:15 | NEW PLANS SUBMITTED. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-11-14 |
Time |
18:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-11-14 |
Time |
18:29 |
Sent To |
|
|
| Notes |
| 2017-11-14 17:47:55 | NEW DRAWINGS SUBMITTED. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-10-13 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2017-10-13 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2017-10-13 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2017-10-13 14:37:50 | 10/13/17 APPROVED SUB PLUMBING PERMIT APPLICATION AND | | | PLANS WILL BE REQUIRED LAC | | 2017-10-02 14:31:00 | NEW SET OF PLANS SUBMITTED. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-08-29 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-08-29 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-08-29 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2017-08-29 14:03:05 | SUB PLUMBING PERMIT APPLICATION AND PLANS WILL BE | | | REQUIRED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-11-28 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-11-28 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2017-11-17 17:23:23 | NEW DRAWINGS SUBMITTED. JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-10-11 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-10-11 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-10-11 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2017-10-02 14:31:24 | NEW SET OF PLANS SUBMITTED. JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-08-25 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-08-25 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-08-25 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|