Plan Review Details - Permit 17080634
Plan Review Stops For Permit 17080634
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-12-19 Cont ID  
Sent By rmcdouga Date 2017-12-19 Time 18:07 Rev Time 0.00
Received By rmcdouga Date 2017-12-19 Time 16:37 Sent To I
Notes
2017-12-19 18:09:45ADJUSTED VALUATION OF WORK FROM $1000.00 TO $10,000.00
 BASED ON THE SCOPE OF WORK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-09-13 Cont ID  
Sent By rmcdouga Date 2017-09-13 Time 14:54 Rev Time 0.00
Received By rmcdouga Date 2017-09-13 Time 07:04 Sent To  
Notes
2017-09-13 14:45:15PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) ON SHEET S.2 OF THE PLANS THE ELEVATIONS INDICATE
 THAT THE EXISTING CARPORT HAS A FLAT ROOF. THE EXTERIOR
 WALL SECTION ON SHEET S.1 SHOWS A VAULTED CEILING.
 PROVIDE CLARIFICATION AND SPECIFY THE CEILING HEIGHT IN
 THE ENCLOSED CARPORT ADDITION ON THE PLANS. SEE
 FBC-R305.1 MINIMUM HEIGHT. HABITABLE SPACE, HALLWAYS,
 BATHROOMS, TOILET ROOMS, LAUNDRY ROOMS AND PORTIONS OF
 BASEMENTS CONTAINING THESE SPACES SHALL HAVE A CEILING
 HEIGHT OF NOT LESS THAN 7 FEET (2134 MM).
  
 2) CLARIFY HOW THE ATTIC SPACE OR ENCLOSED RAFTER
 SPACES WILL BE VENTILATED IN ACCORDANCE WITH FBC-R806.1
 VENTILATION REQUIRED. ENCLOSED ATTICS AND ENCLOSED
 RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED
 DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE
 CROSS VENTILATION FOR EACH SEPARATE SPACE BY
 VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF
 RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST
 DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM AND 1/4 INCH
 (6.4 MM) MAXIMUM. VENTILATION OPENINGS HAVING A LEAST
 DIMENSION LARGER THAN 1/4 INCH (6.4 MM) SHALL BE
 PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH SCREENING,
 HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS
 HAVING A LEAST DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM
 AND 1/4 INCH (6.4 MM) MAXIMUM. OPENINGS IN ROOF FRAMING
 MEMBERS SHALL CONFORM TO THE REQUIREMENTS OF SECTION
 R802.1.8. REQUIRED VENTILATION OPENINGS SHALL OPEN
 DIRECTLY TO THE OUTSIDE AIR.
  
 3) THE VALUATION FOR THE WORK LISTED ON THE APPLICATION
 IS $1000.00. THE VALUATION OF WORK SHOULD BE WHAT A
 CONTRACTOR WILL CHARGE FOR LABOR, MATERIAL AND PROFIT
 FOR THIS PROJECT. FBC 109.3 BUILDING PERMIT VALUATION.
 FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN
 FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE
 LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION COST
 ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS
 PUBLISHED BY INTERNATIONAL CODE CONGRESS. FINAL
 BUILDING PERMIT VALUATION SHALL BE SET BY THE BUILDING
 OFFICIAL.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-12-11 Cont ID  
Sent By jpearson Date 2017-12-11 Time 10:31 Rev Time 0.00
Received By jpearson Date 2017-12-11 Time 09:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-09-06 Cont ID  
Sent By jpearson Date 2017-09-06 Time 16:08 Rev Time 0.00
Received By jpearson Date 2017-09-06 Time 16:08 Sent To B
Notes
2017-09-06 16:07:57CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. RISER DIAGRAM SHOWS A METER MAIN COMBO EXISTING
 FEEDING AN INTERIOR PANEL. PLAN SHOWS A METER AND PANEL
 ON EXTERIOR OF HOUSE. PROVIDE CORRECTION FOR
 DISCREPANCY. FBC 107.2.1; NEC 215.5
 2. IF THERE IS AN INTERIOR PANEL, WIRING TO THE
 INTERIOR PANEL MUST INCLUDE AN EQUIPMENT GROUNDING
 CONDUCTOR. SHOW LOCATION OF PANEL ON PLAN. NEC 250.122;
 FBC 107.2.1, FBC RE3704.6
 3. LOCATION OF INTERSYSTEM BONDING TERMINATION IS SHOWN
 AT THE INTERIOR PANEL. THIS SHOULD BE LOCATED AT MAIN
 SERVICE. PROVIDE CORRECTION. NEC 250.94; FBC RE3609.3
 4. NOTE # 9 STATES THAT RECEPTACLES SHALL BE TAMPER
 RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT
 APPLY TO TAMPER RESISTANT RECEPTACLES. ALSO, THE 2008
 CODE IS CITED, WHICH IS NOT THE CURRENT CODE. PROVIDE
 CORRECTION. NEC 406.12; FBC PREFACE, FBC RE4002.14
 5. BREAKER FOR WATER HEATER IS STATED AS 50 AMP, WHICH
 IS TOO LARGE FOR THE LOAD OF 4500 WATTS SPECIFIED IN
 LOAD CALCULATION. BREAKER SHOULD BE SIZED AT 125% OF
 THE LOAD. PROVIDE CORRECTION. NEC 422.13; FBC RE3702.10
 6. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING
 REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE
 INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG
 THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET
 FROM A RECEPTACLE OUTLET. PROVIDE CORRECTION. NEC
 210.52; FBC RE3901.2.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-04-09 Cont ID  
Sent By cpuell Date 2018-04-09 Time 15:39 Rev Time 0.00
Received By cpuell Date 2018-04-06 Time 10:33 Sent To  
Notes
2018-04-09 10:33:45IMPACT FEES ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-12-19 Cont ID  
Sent By rmcdouga Date 2017-12-19 Time 18:07 Rev Time 0.00
Received By rmcdouga Date 2017-11-20 Time 14:16 Sent To  
Notes
2017-11-21 14:16:56R31

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-09-13 Cont ID  
Sent By rmcdouga Date 2017-09-13 Time 14:55 Rev Time 0.00
Received By rmcdouga Date 2017-08-14 Time 17:06 Sent To  
Notes
2017-08-14 17:06:27R41

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2018-04-09 Cont ID  
Sent By rmcdouga Date 2018-04-09 Time 16:04 Rev Time 0.00
Received By rmcdouga Date 2018-04-09 Time 15:02 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-09-13 Cont ID  
Sent By rmcdouga Date 2017-09-13 Time 07:16 Rev Time 0.00
Received By rmcdouga Date 2017-09-13 Time 07:16 Sent To  
Notes
2017-09-13 07:17:59BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-12-13 Cont ID  
Sent By hmoser Date 2017-12-13 Time 15:04 Rev Time 0.00
Received By hmoser Date 2017-12-13 Time 14:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-09-13 Cont ID  
Sent By rmcdouga Date 2017-09-13 Time 11:09 Rev Time 0.00
Received By rmcdouga Date 2017-09-13 Time 10:19 Sent To  
Notes
2017-09-13 11:09:37PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE NOTES IN THE EQUIPMENT SCHEDULE STATES
 MINI-SPLIT FOR BACK COTTAGE. IT SHOULD READ FOR THE
 ENCLOSED CARPORT ADDITION. FBC 107.2.1
  
 2) THE NOTES IN THE EQUIPMENT SCHEDULE STATES HEAT PUMP
 CONDENSING UNIT IS MATCHED TO THE TWO (2) INDOOR AIR
 HANDLING UNITS LISTED. THE PLANS ONLY SHOW ONE INDOOR
 HANDLING UNIT. FBC 107.2.1
  
 3) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY
 EFFICIENCY FORM R405-2014. FBC ENERGY EFFICIENCY CODE
 SECTION R103.1.1.2
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-12-19 Cont ID  
Sent By gjohnson Date 2017-12-19 Time 16:21 Rev Time 0.00
Received By gjohnson Date 2017-12-19 Time 09:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-08-29 Cont ID  
Sent By thunt Date 2017-08-29 Time 15:09 Rev Time 0.00
Received By thunt Date 2017-08-29 Time 15:09 Sent To  
Notes
2017-08-29 15:10:438/29/17 1ST REVIEW DENIED
  
 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW
 DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED
 CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE
 APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL
 BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE
 LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION
 COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.),
 AS PUBLISHED BY INTERNATIONAL CODE CONGRESS.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2017-12-07 Cont ID  
Sent By ajones Date 2017-12-07 Time 16:07 Rev Time 0.00
Received By ajones Date 2017-12-07 Time 16:07 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-08-18 Cont ID  
Sent By njwira Date 2017-08-18 Time 09:01 Rev Time 0.00
Received By njwira Date 2017-08-17 Time 16:17 Sent To  
Notes
***NONE***