| Plan Review Stops For Permit 17080634 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-12-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-12-19 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-12-19 |
Time |
16:37 |
Sent To |
I |
|
| Notes |
| 2017-12-19 18:09:45 | ADJUSTED VALUATION OF WORK FROM $1000.00 TO $10,000.00 | | | BASED ON THE SCOPE OF WORK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-09-13 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-09-13 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2017-09-13 14:45:15 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) ON SHEET S.2 OF THE PLANS THE ELEVATIONS INDICATE | | | THAT THE EXISTING CARPORT HAS A FLAT ROOF. THE EXTERIOR | | | WALL SECTION ON SHEET S.1 SHOWS A VAULTED CEILING. | | | PROVIDE CLARIFICATION AND SPECIFY THE CEILING HEIGHT IN | | | THE ENCLOSED CARPORT ADDITION ON THE PLANS. SEE | | | FBC-R305.1 MINIMUM HEIGHT. HABITABLE SPACE, HALLWAYS, | | | BATHROOMS, TOILET ROOMS, LAUNDRY ROOMS AND PORTIONS OF | | | BASEMENTS CONTAINING THESE SPACES SHALL HAVE A CEILING | | | HEIGHT OF NOT LESS THAN 7 FEET (2134 MM). | | | | | | 2) CLARIFY HOW THE ATTIC SPACE OR ENCLOSED RAFTER | | | SPACES WILL BE VENTILATED IN ACCORDANCE WITH FBC-R806.1 | | | VENTILATION REQUIRED. ENCLOSED ATTICS AND ENCLOSED | | | RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED | | | DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE | | | CROSS VENTILATION FOR EACH SEPARATE SPACE BY | | | VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF | | | RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST | | | DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM AND 1/4 INCH | | | (6.4 MM) MAXIMUM. VENTILATION OPENINGS HAVING A LEAST | | | DIMENSION LARGER THAN 1/4 INCH (6.4 MM) SHALL BE | | | PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH SCREENING, | | | HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS | | | HAVING A LEAST DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM | | | AND 1/4 INCH (6.4 MM) MAXIMUM. OPENINGS IN ROOF FRAMING | | | MEMBERS SHALL CONFORM TO THE REQUIREMENTS OF SECTION | | | R802.1.8. REQUIRED VENTILATION OPENINGS SHALL OPEN | | | DIRECTLY TO THE OUTSIDE AIR. | | | | | | 3) THE VALUATION FOR THE WORK LISTED ON THE APPLICATION | | | IS $1000.00. THE VALUATION OF WORK SHOULD BE WHAT A | | | CONTRACTOR WILL CHARGE FOR LABOR, MATERIAL AND PROFIT | | | FOR THIS PROJECT. FBC 109.3 BUILDING PERMIT VALUATION. | | | FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR | | | FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN | | | FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | | LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION COST | | | ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS | | | PUBLISHED BY INTERNATIONAL CODE CONGRESS. FINAL | | | BUILDING PERMIT VALUATION SHALL BE SET BY THE BUILDING | | | OFFICIAL. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-12-11 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-11 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-11 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-09-06 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-06 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-06 |
Time |
16:08 |
Sent To |
B |
|
| Notes |
| 2017-09-06 16:07:57 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. RISER DIAGRAM SHOWS A METER MAIN COMBO EXISTING | | | FEEDING AN INTERIOR PANEL. PLAN SHOWS A METER AND PANEL | | | ON EXTERIOR OF HOUSE. PROVIDE CORRECTION FOR | | | DISCREPANCY. FBC 107.2.1; NEC 215.5 | | | 2. IF THERE IS AN INTERIOR PANEL, WIRING TO THE | | | INTERIOR PANEL MUST INCLUDE AN EQUIPMENT GROUNDING | | | CONDUCTOR. SHOW LOCATION OF PANEL ON PLAN. NEC 250.122; | | | FBC 107.2.1, FBC RE3704.6 | | | 3. LOCATION OF INTERSYSTEM BONDING TERMINATION IS SHOWN | | | AT THE INTERIOR PANEL. THIS SHOULD BE LOCATED AT MAIN | | | SERVICE. PROVIDE CORRECTION. NEC 250.94; FBC RE3609.3 | | | 4. NOTE # 9 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. ALSO, THE 2008 | | | CODE IS CITED, WHICH IS NOT THE CURRENT CODE. PROVIDE | | | CORRECTION. NEC 406.12; FBC PREFACE, FBC RE4002.14 | | | 5. BREAKER FOR WATER HEATER IS STATED AS 50 AMP, WHICH | | | IS TOO LARGE FOR THE LOAD OF 4500 WATTS SPECIFIED IN | | | LOAD CALCULATION. BREAKER SHOULD BE SIZED AT 125% OF | | | THE LOAD. PROVIDE CORRECTION. NEC 422.13; FBC RE3702.10 | | | 6. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. PROVIDE CORRECTION. NEC | | | 210.52; FBC RE3901.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-04-09 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-04-06 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2018-04-09 10:33:45 | IMPACT FEES ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-12-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-12-19 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-11-20 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-09-13 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-08-14 |
Time |
17:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-04-09 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-09 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-09-13 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-09-13 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2017-09-13 07:17:59 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-12-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-12-13 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-12-13 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-09-13 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-09-13 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2017-09-13 11:09:37 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE NOTES IN THE EQUIPMENT SCHEDULE STATES | | | MINI-SPLIT FOR BACK COTTAGE. IT SHOULD READ FOR THE | | | ENCLOSED CARPORT ADDITION. FBC 107.2.1 | | | | | | 2) THE NOTES IN THE EQUIPMENT SCHEDULE STATES HEAT PUMP | | | CONDENSING UNIT IS MATCHED TO THE TWO (2) INDOOR AIR | | | HANDLING UNITS LISTED. THE PLANS ONLY SHOW ONE INDOOR | | | HANDLING UNIT. FBC 107.2.1 | | | | | | 3) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY | | | EFFICIENCY FORM R405-2014. FBC ENERGY EFFICIENCY CODE | | | SECTION R103.1.1.2 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-12-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-12-19 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-12-19 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-08-29 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-08-29 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-08-29 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2017-08-29 15:10:43 | 8/29/17 1ST REVIEW DENIED | | | | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW | | | DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED | | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE | | | APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL | | | BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | | LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-12-07 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2017-12-07 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2017-12-07 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-08-18 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-08-18 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-08-17 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|