| 2017-08-17 17:06:52 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER, PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. PROVIDE DESIGN WIND LOADS FOR PROPOSED STRUCTURE. |
| | 2002.4 LOADS. |
| | STRUCTURAL MEMBERS SUPPORTING SCREENED ENCLOSURES SHALL |
| | BE DESIGNED FOR WIND IN BOTH OF TWO ORTHOGONAL |
| | DIRECTIONS USING THE PRESSURES GIVEN IN TABLE 2002.4. |
| | EACH PRIMARY MEMBER SHALL ALSO BE DESIGNED FOR A 300 |
| | POUND (1.33 KN) LOAD APPLIED VERTICALLY DOWNWARD ALONG |
| | ANY 1 FOOT (305 MM) OF ANY MEMBER, NOT OCCURRING |
| | SIMULTANEOUSLY WITH WIND LOAD. |
| | |
| | 2. PROVIDE CONNECTOR SCHEDULE FOR COLUMN TO FOUNDATION, |
| | COLUMN TO BEAM, BEAM TO INSULATED PANEL AND INSULATED |
| | PANEL TO EXISTING STRUCTURE. SCHEDULE TO INCLUDE |
| | FASTENER TYPE, SIZE, LENGTH AND SPACING. |
| | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE |
| | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE |
| | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT |
| | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | 3. DESIGNER TO PRINT NAME AND SIGN PLAN. |
| | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL |
| | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING |
| | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON |
| | RESPONSIBLE FOR THE DESIGN. |