Plan Review Details - Permit 17080575
Plan Review Stops For Permit 17080575
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-10-02 Cont ID  
Sent By jpearson Date 2017-10-02 Time 08:54 Rev Time 0.00
Received By jpearson Date 2017-10-02 Time 08:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-08-28 Cont ID  
Sent By jpearson Date 2017-08-28 Time 13:42 Rev Time 0.00
Received By jpearson Date 2017-08-28 Time 13:42 Sent To  
Notes
2017-08-28 13:42:13CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE LOAD CALCULATION FOR SERVICE TO DETERMINE
 THAT THE SERVICE SIZE IS ADEQUATE. NEC 220; FBC
 RE3602.3
 2. SMOKE ALARMS SHALL BE FED FROM THE POWER SOURCE IN
 EACH INDIVIDUAL UNIT. PROVIDE CORRECTION. FBC R314.5
 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. NEC 250.94; FBC RE3609.3
 4. PROVIDE PANEL SCHEDULE OF EACH PANEL INDICATING
 WHICH BREAKERS ARE BEING REPLACED. NOTE THAT IF THERE
 IS PAINT ON THE BUSBARS OF THE PANELS, THOSE PANELS
 WILL NEED TO BE REPLACED PER CONVERSATION WITH DAN
 KEMPA. PROVIDE NOTE TO INDICATE STATUS OF PANELS, AS
 THE NOTE IN THE CITY'S SYSTEM STATES THAT THE PANELS
 HAVE BEEN COMPLETELY PAINTED. NEC 110.3, 110.12(B),
 215.5, 408.4; FBC RE3706.2
 5. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE OF WORK
 AND VALUE STATED. FBC 109.3
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-10-02 Cont ID  
Sent By jpearson Date 2017-10-02 Time 08:54 Rev Time 0.00
Received By jpearson Date 2017-09-18 Time 09:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-08-28 Cont ID  
Sent By jpearson Date 2017-08-28 Time 13:42 Rev Time 0.00
Received By jpearson Date 2017-08-16 Time 09:33 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2017-10-02 Cont ID  
Sent By jpearson Date 2017-10-02 Time 08:54 Rev Time 0.00
Received By jpearson Date 2017-10-02 Time 08:54 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2017-08-28 Cont ID  
Sent By jpearson Date 2017-08-28 Time 13:01 Rev Time 0.00
Received By jpearson Date 2017-08-28 Time 13:01 Sent To  
Notes
2017-08-28 13:06:32[email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved