Plan Review Details - Permit 17080539
Plan Review Stops For Permit 17080539
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-11-14 Cont ID  
Sent By shill Date 2017-11-14 Time 07:53 Rev Time 0.00
Received By shill Date 2017-11-14 Time 07:53 Sent To  
Notes
2017-11-14 07:54:02****PROVISO****
 ISSUED AT APPLICANT'S RISK
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 A COMPREHENSIVE PLAN REVIEW IS NOT PERFORMED ON
 DELEGATED ENGINEERING AS THE ENGINEERING IS TO COMPLY
 WITH THE FLORIDA BUILDING CODE AND THE
 APPROVED/REVIEWED PLAN. DEVIATION FROM THE PLANS AND/OR
 FBC IS TO BE SUBMITTED AS A REVISION FROM THE DESIGNER
 OF RECORD.
  
 INSTALLATION TO BE IN ACCORDANCE WITH THE REVIEWED
 PLANS (PERMIT DOCUMENTS) PERMITTED UNDER MASTER PERMIT:
  
 #16020194
  
 AND FBC 2014. ANY DEVIATION FROM THE ISSUED MASTER
 PERMIT OR FBC 2014 IS REQUIRED TO BE SUBMITTED AS A
 REVISION, PREPARED BY DESIGNER OF RECORD.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-09-13 Cont ID  
Sent By shill Date 2017-09-13 Time 10:24 Rev Time 0.00
Received By shill Date 2017-09-13 Time 10:24 Sent To  
Notes
2017-09-13 10:41:06****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. SHEET SD01 DESIGN CRITIERA IS 170MPH EXPOSURE C, BUT
 GATE HAS PROPOSED DESIGN CRITERIA OF 115MPH. REVISE
 COVER PAGE (SD01) TO CLARIFY DESIGN CRITERIA, FBC 107,
 FBC B 1609.
  
 2. FBC B 1609, FBC 107, CALCULATIONS FOR ROLLING GATE
 ARE FOR 115 MPH. SD10 DECLARES 170MPH EXPOSURE C AND
 ALSO STATES THAT "GATE SHALL REMAIN IN OPEN SECURED
 POSITION DURING WINDSTORM EVENTS WITH SUSTAINED WINDS
 OVER 115 MPH".
  
 REVISE PLAN TO INDICATE CODE SECTION WHICH ALLOWS THIS
 WIND DESIGN.
  
 REVISE CALCULATIONS TO BE CONSISTENT WITH THE WIND
 DESIGN CRITERIA ON THE PLAN.
  
 CLARIFY HOW THIS WILL BE ENFORCED. HOW WILL OTHERS
 (MANAGEMENT, FUTURE MANAGEMENT, FUTURE OWNERS) KNOW
 THAT THE GATE MUST BE SECURED? THIS IS NOT A TYPICAL
 DESIGN.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-11-28 Cont ID  
Sent By shill Date 2017-11-28 Time 06:14 Rev Time  
Received By shill Date 2017-10-31 Time 12:37 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-17 Cont ID  
Sent By cpuell Date 2017-10-17 Time 15:56 Rev Time 0.00
Received By cpuell Date 2017-08-30 Time 13:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2017-11-14 Cont ID  
Sent By shill Date 2017-11-14 Time 07:55 Rev Time 0.00
Received By shill Date 2017-11-14 Time 07:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2017-09-13 Cont ID  
Sent By shill Date 2017-09-13 Time 11:31 Rev Time 0.00
Received By shill Date 2017-09-13 Time 11:31 Sent To  
Notes
2017-09-13 11:31:39DIGITAL SIGNATURES OK
 RESUBMITTED REVISED DOCUMENTS WILL REQUIRE SIGNATURE
 VERIFICATION 2ND REVIEW
  

Review Stop Z ZONING
Rev No 2 Status N Date 2017-11-21 Cont ID  
Sent By aaponte Date 2017-11-21 Time 08:47 Rev Time 0.00
Received By aaponte Date 2017-11-21 Time 08:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2017-10-17 Cont ID  
Sent By aaponte Date 2017-10-17 Time 14:46 Rev Time 0.00
Received By aaponte Date 2017-10-17 Time 14:45 Sent To  
Notes
***NONE***