| Plan Review Stops For Permit 17080530 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-11-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-11-21 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-11-21 |
Time |
11:44 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-09-13 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-09-13 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2017-09-13 13:43:43 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DESIGN PROFESSIONALS TO SIGN AND SEAL PLANS. | | | | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. | | | | | | PROVIDE SIGNATURE AND SEAL FOR VLAD DUMITRESCU, | | | ARCHITECT OF RECORD AND ANDREW J. MORGAN, P.E. FOR | | | ENGINEER OF RECORD PER F.S. 481 & 471 RESPECTIVELY. | | | | | | 61G1-16.001 ARCHITECT?S AND INTERIOR DESIGNER?S SEAL. | | | EACH ARCHITECT AND INTERIOR DESIGNER SHALL ACQUIRE A | | | SEAL WITH WHICH SHE OR HE SHALL IDENTIFY ALL PLANS, | | | SPECIFICATIONS OR REPORTS PREPARED OR ISSUED BY HER OR | | | HIM AND FILED FOR PUBLIC RECORD. THE SEAL SHALL BE | | | CAPABLE OF LEAVING A PERMANENT INK REPRESENTATION OR | | | OTHER FORM OF EMBOSSING OR OPAQUE AND PERMANENT | | | IMPRESSION, WHICH ALSO MAY BE COMPUTER GENERATED | | | IMPRESSIONS, ON THE SURFACE OF PRINTS OR OTHER | | | DUPLICATIONS OF DRAWINGS, AND, AS APPROPRIATE, UPON | | | SPECIFICATION PAGES, AND OTHER ARTICLES OF SERVICE. | | | WHERE REQUIRED, ELECTRONIC FILES MAY BE SEALED IN | | | ACCORDANCE WITH RULE 61G1-16.005, F.A.C. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-11-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-21 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-21 |
Time |
13:37 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-08-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-29 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-29 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2017-08-29 09:21:54 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RECEPTACLES SPACED PER CODE: RECEPTACLES | | | SHALL BE INSTALLED SO THAT NO POINT MEASURED | | | HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL SPACE IS | | | MORE THAN 6 FEET FROM A RECEPTACLE OUTLET. PROVIDE | | | CORRECTION. NEC 210.52; FBC RE3901.2.1 | | | 2. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES OR EXITS WITH | | | GRADE LEVEL ACCESS. PROVIDE CORRECTION. NEC | | | 210.70(A)(2)(B), FBC RE3903.3 | | | 3. PROVIDE FLOOR PLAN SHOWING ALL EXISTING SMOKE | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC R314.3, FBC 107.2.1 | | | 4. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC | | | RE3706.2, RE3902 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-11-08 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-11-08 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-11-08 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-08-18 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-08-18 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-08-18 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-12-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-12-04 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-12-01 |
Time |
12:56 |
Sent To |
I |
|
| Notes |
| 2017-12-04 12:57:07 | RESUB ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-11-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-21 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-02 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-09-13 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-08-10 |
Time |
13:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-09-13 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-09-13 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2017-12-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-12-04 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-12-04 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2017-11-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-11-21 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-11-21 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2017-11-21 12:36:18 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM | | | COMPONENETS. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | -OR- | | | | | | YOU MAY ELECT TO DEFER YOUR ROOFING SUBMITTALS | | | | | | 2. 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | -OR- | | | | | | 3. YOU MAY ELECT TO APPLY FOR A STAND ALONE ROOFING | | | PERMIT. IF YOU CHOOSE THIS OPTION YOU MAY REDUCE THE | | | VALUE OF THE PRIMARY PERMIT BY AN APPROPRIATE AMOUNT | | | AND YOUR ROOFING CONTRACTOR SHALL PAY ANY FEES DUE FOR | | | THE ROOFING PERMIT. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-09-13 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-09-13 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2017-09-13 13:21:41 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING PERMIT REQUIRED. | | | 2. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM | | | COMPONENTS. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-11-08 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-11-08 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-11-08 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-08-18 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-08-18 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-08-18 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|