Plan Review Details - Permit 17080446
Plan Review Stops For Permit 17080446
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-09-13 Cont ID  
Sent By shill Date 2017-09-13 Time 12:15 Rev Time 0.00
Received By shill Date 2017-09-13 Time 12:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-08-15 Cont ID  
Sent By shill Date 2017-08-15 Time 17:59 Rev Time 0.00
Received By shill Date 2017-08-15 Time 17:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2017-10-04 Cont ID  
Sent By jpearson Date 2017-10-04 Time 06:57 Rev Time 0.00
Received By jpearson Date 2017-10-04 Time 06:57 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2017-09-18 Cont ID  
Sent By jpearson Date 2017-09-18 Time 11:09 Rev Time 0.00
Received By jpearson Date 2017-09-18 Time 11:08 Sent To  
Notes
2017-09-18 11:08:55CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENT NOT ADDRESSED:
 2. PROVIDE INTERIOR LIGHTING CALCULATION SHOWING
 COMPLIANCE WITH THE FBC ENERGY CODE. FBC C405.5
 (PROVIDE CALCULATION SHOWING THE ALLOWED WATTAGE FOR
 THE AREA AND THE PROPOSED WATTAGE TO BE INSTALLED, IN
 COMPLIANCE WITH CODE.)
  
 NEW COMMENT:
 1. EMERGENCY AND EXIT LIGHTS ARE REQUIRED TO BE FED
 FROM THE GENERAL LIGHTING CIRCUIT IN THE AREA. THERE
 SHOULD NOT BE A SEPARATE CIRCUIT FOR THESE ITEMS.
 PROVIDE CORRECTION. NEC 700.12(F)
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-08-15 Cont ID  
Sent By jpearson Date 2017-08-15 Time 14:49 Rev Time 0.00
Received By jpearson Date 2017-08-15 Time 14:49 Sent To  
Notes
2017-08-15 14:49:34CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE A BLOCK NOTE INDICATING THE REQUIRED
 SEPARATE PERMITS AND DATA SPECIFICATION SHEET
 SUBMITTALS FOR ALL LOW VOLTAGE SYSTEMS TO INCLUDE BUT
 NOT LIMITED TO FIRE ALARM, CCTV, PHONE AND DATA,
 WIRELESS SYSTEMS, KITCHEN HOODS ETC. FBC 105.1
 2. PROVIDE INTERIOR LIGHTING CALCULATION SHOWING
 COMPLIANCE WITH THE FBC ENERGY CODE. FBC C405.5
 3. PROVIDE THE ADDITIONAL LIGHTING CONTROLS STIPULATED
 IN THE FBC ENERGY CODE. MANY AREAS DO NOT SHOW A
 TIMECLOCK CONTROLLED CIRCUIT OR AN OCCUPANCY SENSORS.
 FBC C405.2.2, 405.2.2.2
 4. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1:
 8.4.2. FBC C405.7.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-09-05 Cont ID  
Sent By pleduc Date 2017-09-05 Time   Rev Time 0.00
Received By pleduc Date 2017-09-05 Time 11:32 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-08-14 Cont ID  
Sent By pleduc Date 2017-08-14 Time   Rev Time 0.00
Received By pleduc Date 2017-08-14 Time 10:49 Sent To  
Notes
2017-08-14 12:02:05THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) SHEET M1 - A 3,000 CFM A/C UNIT IS PROPOSED. A DUCT
 DETECTOR IS NOT READILL INDICATED OR NOTED.
 PER NFPA NFPA 90A, STANDARD FOR THE INSTALLATION OF
 AIR-CONDITIONING AND VENTILATING SYSTEMS, 2012 EDITION.
  
 CHAPTER 6 CONTROLS
 6.4* SMOKE DETECTION FOR AUTOMATIC CONTROL.
 6.4.1 TESTING. ALL AUTOMATIC SHUTDOWN DEVICES SHALL BE
 TESTED AT LEAST ANNUALLY.
 6.4.2* LOCATION.
 6.4.2.1 SMOKE DETECTORS LISTED FOR USE IN AIR
 DISTRIBUTION SYSTEMS SHALL BE LOCATED AS FOLLOWS:
 (1) DOWNSTREAM OF THE AIR FILTERS AND AHEAD OF ANY
 BRANCH CONNECTIONS IN AIR SUPPLY SYSTEMS HAVING A
 CAPACITY GREATER THAN 944 L/SEC (2000 FT3/MIN)
 (2) AT EACH STORY PRIOR TO THE CONNECTION TO A COMMON
 RETURN AND PRIOR TO ANY RECIRCULATION OR FRESH AIR
 INLET CONNECTION IN AIR RETURN SYSTEMS HAVING A
 CAPACITY GREATER THAN 7080 L/SEC (15,000 FT3/MIN) AND
 SERVING MORE THAN ONE STORY
  
  
 PLEASE ENSURE THE REQUIREMENT IS MET AND PROVIDE THE
 APPLICABLE REVISION PRIOR TO FIRE FINAL.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2017-10-10 Time   Rev Time 0.00
Received By lmarchan Date 2017-10-02 Time 13:50 Sent To  
Notes
2017-10-03 13:51:05RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-09-22 Cont ID  
Sent By gjohnson Date 2017-09-22 Time 17:56 Rev Time 0.00
Received By gjohnson Date 2017-08-30 Time 16:06 Sent To  
Notes
2017-08-31 16:06:54B23

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-08-22 Cont ID  
Sent By gjohnson Date 2017-08-22 Time 18:06 Rev Time 0.00
Received By gjohnson Date 2017-08-09 Time 15:41 Sent To  
Notes
2017-08-10 15:41:32B19

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-10-19 Cont ID  
Sent By ccole Date 2017-10-10 Time 12:31 Rev Time 0.00
Received By ccole Date 2017-10-10 Time 07:36 Sent To  
Notes
2017-10-10 12:34:023RD REVIEW FBC-2014 MECHANICAL
 PERMIT #17080446
 10/10/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) COMMENT #2 FROM THE PREVIOUS REVIEW WAS NOT
 ADDRESSED AND STILL EXISTS. I HAVE REPRINTED IT BELOW.
  
 M2: THE WIND DESIGN CRITERIA USING ULTIMATE WIND SPEED
 OF 140 MPH BASED ON THE ASCE 7-05 IS OUTDATED- SEE
 SECTION1609.1.1 FBC-14 BUILDING. THE ULTIMATE WIND
 SPEED FOR WEST PALM BEACH IS 170 MPH BASED ON THE
 CURRENT EDITION OF ASCE 7-2010- PLEASE CORRECT.
  
 2) NEW COMMENT: THE DIRECTIONAL ARROWS FOR THE AIRFLOW
 OF THE RETURN AIR DUCTWORK ARE POINTING IN THE WRONG
 DIRECTION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-09-14 Cont ID  
Sent By ccole Date 2017-09-14 Time 17:10 Rev Time 0.00
Received By ccole Date 2017-09-14 Time 15:52 Sent To  
Notes
2017-09-14 17:36:321ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17080446
 9/14/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M1: CLARIFY HOW MAKEUP WILL BE PROVIDED FOR
 THE EXHAUST VENTILATION SYSTEM IN THE TRAINING ROOM
 WHICH IS REQUIRED TO RUN CONTINUOUSLY WHEN THE ROOM IS
 OCCUPIED- SEE SECTION 501.4.
  
 2) M2: THE WIND DESIGN CRITERIA USING ULTIMATE WIND
 SPEED OF 140 MPH BASED ON THE ASCE 7-05 IS OUTDATED-
 SEE SECTION1609.1.1 FBC-14 BUILDING. THE ULTIMATE WIND
 SPEED FOR WEST PALM BEACH IS 170 MPH BASED ON THE
 CURRENT EDITION OF ASCE 7-2010.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-08-22 Cont ID  
Sent By ccole Date 2017-08-22 Time 08:59 Rev Time 0.00
Received By ccole Date 2017-08-22 Time 08:59 Sent To  
Notes
2017-08-22 09:16:371ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17080446
 8/22/17
  
 1) EXHAUST VENTILATION AT A RATE OF 0.5 CFMS PER SQ.
 FT. IS REQUIRED FOR THE BARBER SHOP AREA- TABLE 403.3.
 PLEASE PROVIDE A SYSTEM AND REVISE THE PLANS AND THE
 AIR BALANCE CALCULATIONS ACCORDINGLY.
  
 2) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE
 NEW RTU- SECTION C403.2.1 FBC-14 ENERGY CONSERVATION.
  
 3) PROVIDE A DUCT SMOKE DETECTOR IN THE RETURN AIR
 SYSTEM OF THE NEW RTU- SECTION 606.2.1
  
 4) REFER TO SECTION 301.15 AND PROVIDE ENGINEERED
 STRUCTURAL DETAILS FOR INSTALLATION OF THE NEW RTU
 INCLUDING THE ROOF OPENING AND REINFORCEMENTS, CURB AND
 RTU ATTACHMENTS. PLEASE INCLUDE THE WIND LOAD DESIGN
 CRITERIA AS SPECIFIED IN SECTION 1609 FBC-14 BUILDING.
  
 5) PROVIDE A CONDENSATE DISPOSAL PLAN FOR THE RTU.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-09-22 Cont ID  
Sent By gjohnson Date 2017-09-22 Time 17:56 Rev Time 0.00
Received By gjohnson Date 2017-09-22 Time 17:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-08-22 Cont ID  
Sent By gjohnson Date 2017-08-22 Time 17:52 Rev Time 0.00
Received By gjohnson Date 2017-08-22 Time 15:21 Sent To  
Notes
2017-08-22 18:06:021ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. SHOW CLEAR FLOOR SPACE AT BREAKROOM SINK . PER FBC
 ACC 606.2
  
 2. SHT. P1 WATER METER DETAIL THE THE WATTS 009-QT THAT
 IS LISTED IS NOT A LEAD FREE DEVISE AND SHALL NOT BE
 USED. A SEPARATE PERMIT IS REQUIRED FOR BACKFLOW.
  
 3. A WATER-HAMMER ARRESTOR SHALL BE INSTALLED WHERE
 QUICK-CLOSING VALVES ARE UTILIZED WATER FOUNTAIN EXT.
 PER FBC PL604.9
  
 4. FULL-OPEN VALVES SHALL BE INSTALLED ON THE TOP OF
 EVERY WATER DOWN-FEED PIPE. PER FBC PL 606.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  