| Plan Review Stops For Permit 17080446 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-13 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-09-13 |
Time |
12:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-08-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-15 |
Time |
17:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-15 |
Time |
17:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-10-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-04 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-04 |
Time |
06:57 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-09-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-18 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-18 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2017-09-18 11:08:55 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENT NOT ADDRESSED: | | | 2. PROVIDE INTERIOR LIGHTING CALCULATION SHOWING | | | COMPLIANCE WITH THE FBC ENERGY CODE. FBC C405.5 | | | (PROVIDE CALCULATION SHOWING THE ALLOWED WATTAGE FOR | | | THE AREA AND THE PROPOSED WATTAGE TO BE INSTALLED, IN | | | COMPLIANCE WITH CODE.) | | | | | | NEW COMMENT: | | | 1. EMERGENCY AND EXIT LIGHTS ARE REQUIRED TO BE FED | | | FROM THE GENERAL LIGHTING CIRCUIT IN THE AREA. THERE | | | SHOULD NOT BE A SEPARATE CIRCUIT FOR THESE ITEMS. | | | PROVIDE CORRECTION. NEC 700.12(F) | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-08-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-15 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-15 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2017-08-15 14:49:34 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE A BLOCK NOTE INDICATING THE REQUIRED | | | SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR ALL LOW VOLTAGE SYSTEMS TO INCLUDE BUT | | | NOT LIMITED TO FIRE ALARM, CCTV, PHONE AND DATA, | | | WIRELESS SYSTEMS, KITCHEN HOODS ETC. FBC 105.1 | | | 2. PROVIDE INTERIOR LIGHTING CALCULATION SHOWING | | | COMPLIANCE WITH THE FBC ENERGY CODE. FBC C405.5 | | | 3. PROVIDE THE ADDITIONAL LIGHTING CONTROLS STIPULATED | | | IN THE FBC ENERGY CODE. MANY AREAS DO NOT SHOW A | | | TIMECLOCK CONTROLLED CIRCUIT OR AN OCCUPANCY SENSORS. | | | FBC C405.2.2, 405.2.2.2 | | | 4. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1: | | | 8.4.2. FBC C405.7.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-09-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-09-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-09-05 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-08-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-08-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-08-14 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2017-08-14 12:02:05 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) SHEET M1 - A 3,000 CFM A/C UNIT IS PROPOSED. A DUCT | | | DETECTOR IS NOT READILL INDICATED OR NOTED. | | | PER NFPA NFPA 90A, STANDARD FOR THE INSTALLATION OF | | | AIR-CONDITIONING AND VENTILATING SYSTEMS, 2012 EDITION. | | | | | | CHAPTER 6 CONTROLS | | | 6.4* SMOKE DETECTION FOR AUTOMATIC CONTROL. | | | 6.4.1 TESTING. ALL AUTOMATIC SHUTDOWN DEVICES SHALL BE | | | TESTED AT LEAST ANNUALLY. | | | 6.4.2* LOCATION. | | | 6.4.2.1 SMOKE DETECTORS LISTED FOR USE IN AIR | | | DISTRIBUTION SYSTEMS SHALL BE LOCATED AS FOLLOWS: | | | (1) DOWNSTREAM OF THE AIR FILTERS AND AHEAD OF ANY | | | BRANCH CONNECTIONS IN AIR SUPPLY SYSTEMS HAVING A | | | CAPACITY GREATER THAN 944 L/SEC (2000 FT3/MIN) | | | (2) AT EACH STORY PRIOR TO THE CONNECTION TO A COMMON | | | RETURN AND PRIOR TO ANY RECIRCULATION OR FRESH AIR | | | INLET CONNECTION IN AIR RETURN SYSTEMS HAVING A | | | CAPACITY GREATER THAN 7080 L/SEC (15,000 FT3/MIN) AND | | | SERVING MORE THAN ONE STORY | | | | | | | | | PLEASE ENSURE THE REQUIREMENT IS MET AND PROVIDE THE | | | APPLICABLE REVISION PRIOR TO FIRE FINAL. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-10-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-10-02 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2017-10-03 13:51:05 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-09-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-22 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-30 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-08-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-08-22 |
Time |
18:06 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-09 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-10-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-10-10 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-10-10 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2017-10-10 12:34:02 | 3RD REVIEW FBC-2014 MECHANICAL | | | PERMIT #17080446 | | | 10/10/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) COMMENT #2 FROM THE PREVIOUS REVIEW WAS NOT | | | ADDRESSED AND STILL EXISTS. I HAVE REPRINTED IT BELOW. | | | | | | M2: THE WIND DESIGN CRITERIA USING ULTIMATE WIND SPEED | | | OF 140 MPH BASED ON THE ASCE 7-05 IS OUTDATED- SEE | | | SECTION1609.1.1 FBC-14 BUILDING. THE ULTIMATE WIND | | | SPEED FOR WEST PALM BEACH IS 170 MPH BASED ON THE | | | CURRENT EDITION OF ASCE 7-2010- PLEASE CORRECT. | | | | | | 2) NEW COMMENT: THE DIRECTIONAL ARROWS FOR THE AIRFLOW | | | OF THE RETURN AIR DUCTWORK ARE POINTING IN THE WRONG | | | DIRECTION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-09-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-09-14 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-09-14 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2017-09-14 17:36:32 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17080446 | | | 9/14/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M1: CLARIFY HOW MAKEUP WILL BE PROVIDED FOR | | | THE EXHAUST VENTILATION SYSTEM IN THE TRAINING ROOM | | | WHICH IS REQUIRED TO RUN CONTINUOUSLY WHEN THE ROOM IS | | | OCCUPIED- SEE SECTION 501.4. | | | | | | 2) M2: THE WIND DESIGN CRITERIA USING ULTIMATE WIND | | | SPEED OF 140 MPH BASED ON THE ASCE 7-05 IS OUTDATED- | | | SEE SECTION1609.1.1 FBC-14 BUILDING. THE ULTIMATE WIND | | | SPEED FOR WEST PALM BEACH IS 170 MPH BASED ON THE | | | CURRENT EDITION OF ASCE 7-2010. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-22 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-22 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2017-08-22 09:16:37 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17080446 | | | 8/22/17 | | | | | | 1) EXHAUST VENTILATION AT A RATE OF 0.5 CFMS PER SQ. | | | FT. IS REQUIRED FOR THE BARBER SHOP AREA- TABLE 403.3. | | | PLEASE PROVIDE A SYSTEM AND REVISE THE PLANS AND THE | | | AIR BALANCE CALCULATIONS ACCORDINGLY. | | | | | | 2) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW RTU- SECTION C403.2.1 FBC-14 ENERGY CONSERVATION. | | | | | | 3) PROVIDE A DUCT SMOKE DETECTOR IN THE RETURN AIR | | | SYSTEM OF THE NEW RTU- SECTION 606.2.1 | | | | | | 4) REFER TO SECTION 301.15 AND PROVIDE ENGINEERED | | | STRUCTURAL DETAILS FOR INSTALLATION OF THE NEW RTU | | | INCLUDING THE ROOF OPENING AND REINFORCEMENTS, CURB AND | | | RTU ATTACHMENTS. PLEASE INCLUDE THE WIND LOAD DESIGN | | | CRITERIA AS SPECIFIED IN SECTION 1609 FBC-14 BUILDING. | | | | | | 5) PROVIDE A CONDENSATE DISPOSAL PLAN FOR THE RTU. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-09-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-22 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-22 |
Time |
17:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-08-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-08-22 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-22 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2017-08-22 18:06:02 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHOW CLEAR FLOOR SPACE AT BREAKROOM SINK . PER FBC | | | ACC 606.2 | | | | | | 2. SHT. P1 WATER METER DETAIL THE THE WATTS 009-QT THAT | | | IS LISTED IS NOT A LEAD FREE DEVISE AND SHALL NOT BE | | | USED. A SEPARATE PERMIT IS REQUIRED FOR BACKFLOW. | | | | | | 3. A WATER-HAMMER ARRESTOR SHALL BE INSTALLED WHERE | | | QUICK-CLOSING VALVES ARE UTILIZED WATER FOUNTAIN EXT. | | | PER FBC PL604.9 | | | | | | 4. FULL-OPEN VALVES SHALL BE INSTALLED ON THE TOP OF | | | EVERY WATER DOWN-FEED PIPE. PER FBC PL 606.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|