Plan Review Details - Permit 17080240
| Plan Review Stops For Permit 17080240 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-11-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-21 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-14 |
Time |
08:56 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-08-16 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-04 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2017-08-07 13:09:44 | REVISION ROUTED TO GJOHNSON |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-11-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-21 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-21 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-08-16 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-16 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2017-08-16 15:59:57 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE ISOMETRIC DRAWING DOES NOT MATCH LAYOUT OF FLOOR | | | PLAN. PER WPB AMEND TO FBC 107.2.1 | | | 2. INDICATE EXISTING PIPING AND NEW PIPING ON PLAN . | | | PER WPB AMEND TO FBC 107.2.1 | | | 3. SHT. P-1 SHOWER IS NOT VENTED WC IS NOT VENTED THE | | | WASHING MACHINE AND KITCHEN SHALL CONNECT TO BUILDING | | | DRAIN SEPARATELY FROM THE BATHROOM GROUP. PER FBC RES | | | P3108.1 | | | 4. PROVIDE SIZING CALCULATIONS SHOWING THAT 1/2 WILL | | | SUPPLY WATER FOR ALL PLUMBING FIXTURES TO COMPLY WITH | | | FBC RES P2903.1 AND TABLE P2903.1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | |
|
|
|