Plan Review Details - Permit 17080142
| Plan Review Stops For Permit 17080142 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-11-16 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2018-11-16 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2018-11-16 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2018-11-16 08:24:17 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 17080142 | | | 3RD REVIEW: DHARVEY 11/16/18 | | | | | | PREVIOUS COMMENTS: | | | I CLEARED COMMENT #1 SINCE I LOCATED THE CONVERSION OF | | | NGVD29 TO NAVD88 ON G-3. | | | HOWEVER, THE REMAINING COMMENTS WERE NOT ADDRESSED. | | | THERE WAS NO COMMENT RESPONSE SHEET FOR FIRST REVIEW | | | BUILDING COMMENTS AND ONLY E-SHEETS WERE UPDATED. | | | PLEASE PROVIDE COMMENT RESPONSE SHEETS AND | | | UPDATED/CLOUDED SHEETS AS NEEDED TO ADDRESS THE | | | COMMENTS. | | | | | | | | | | | | 2017-08-22 15:57:40 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17080142 | | | ADD: 1100 N. FLAGLER DR. LIFT STATION # 20 (SANITARY | | | SEWER) | | | CONT: TBD/ TO BE DETERMINED | | | TEL: 561-801-3659 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. AUGUST 22, 2017 | | | ACTION: DENIED | | | | | | 1) OK. | | | | | | 2) THE 2ND ISSUE OR UNKNOWN IS WHEN THIS LIFT STATION | | | WAS BUILT TO DETERMINE IF IT IS A PRE-FIRM OR POST FIRM | | | STRUCTURE? PLEASE PROVIDE WHEN THIS STRUCTURE WAS | | | BUILT. | | | RESPONSE: THIS IS A REPAIR AND THE COST DOES NOT EXCEED | | | THE 50% THRESHOLD | | | | | | 3) THE OTHER ISSUE TO DETERMINE TO WHAT EXTENT THIS | | | STRUCTURE HAS TO COMPLY IS WHAT DOLLAR AMOUNT IS THE | | | LIFT STATION, OR ANOTHER WORD HAS THE LIFT STATION HIT | | | THE 50% OF THE STRUCTURE VALUE AND NEED TO MEET THE | | | STANDARDS OF THE CURRENT CODE. | | | | | | COMMENT: REPAIR AND CURRENT CODE IS NOT APPLICABLE | | | | | | 4) SHEET G-2 THE GENERAL NOTES DOES NOT LIST THE DESIGN | | | CRITERIA FOR THIS BUILDING. OCCUPANCY TYPE WOULD BE | | | UTILITY. IN THE SPECS THIS FACILITY IS LISTED AS A | | | FORCE MAIN AND IT WOULD BE ASSUMED TO BE A RISK | | | CATEGORY III STRUCTURE. SEE TABLE 1604.5 OF THE 2014 | | | FBC-B. THE QUESTION IS THIS BUILDING AND OPERATION TO | | | BE CONSIDERED A WASTE WATER TREATMENT FACILITY AND | | | OTHER PUBLIC UTILITY FACILITIES NOT INCLUDED IN RISK | | | CATEGORY IV, THE RISK CATEGORY WOULD BE A III. | | | COMMENT: EXISTING AND THIS IS JUST A REPAIR TO KEEP IT | | | WORKING | | | | | | 5) 2014 FBC-B 1612.4 DESIGN AND CONSTRUCTION. THE | | | DESIGN AND CONSTRUCTION OF BUILDINGS AND STRUCTURES | | | LOCATED IN FLOOD HAZARD AREAS, INCLUDING COASTAL HIGH | | | HAZARD AREAS, SHALL BE IN ACCORDANCE WITH CHAPTER 5 OF | | | ASCE 7 AND WITH ASCE 24. PLEASE REVIEW IN THE ASCE/ SEI | | | 24-05 THE DEFINITION FOR COASTAL A ZONE. | | | COASTAL A ZONE. IN A COASTAL A ZONE, THE PRINCIPLE | | | SOURCES OF FLOODING MUST BE ASTRONOMICAL HIGH TIDES, | | | STORM SURGE, SEICHES OR TSUNAMIS. DURING THE BASE FLOOD | | | CONDITIONS, THE POTENTIAL FOR BREAKING WAVE HEIGHTS | | | SHALL BE GREATER THAN OR EQUAL TO 1.5 FEET. PLEASE | | | REVIEW ASCE/ SEI TABLE 4-1 AND THE REQUIRED HEIGHT | | | ABOVE EITHER THE BASE FLOOD OR THE DFE. ON THE NEW MAPS | | | NOT ADOPTED AS OF THIS REVIEW THE DESIGN FLOOD | | | ELEVATION, THE DESIGN FLOOD, INCLUDING WAVE HEIGHT, | | | RELATIVE TO THE DATUM SPECIFIED ON THE COMMUNITY?S | | | FLOOD HAZARD MAP. THERE ARE 2 HEIGHTS GIVEN WHEN THE | | | MEMBER ORIENTATION RELATIVE TO THE DIRECTION OF THE | | | WAVE APPROACH: | | | PARALLEL BFE + 1 FT. OR DFE WHICHEVER IS HIGHER. | | | PERPENDICULAR BFE + 2 FT. OR DFE, WHICHEVER IS HIGHER. | | | | | | PLEASE NOTE FROM THE CITY OF WEST PALM BEACH SUMMARY OF | | | COASTAL STILLWATER STUDY TABLE 9 FOR THIS SECTION OF | | | THE INTERCOASTAL WATER WAY GIVEN IN NAV88 IS 7.3 FT. | | | COMMENT: REPAIR LESS THAN 50% AND CURRENT RULES ARE NOT | | | APPLICABLE | | | | | | APPEAR THAT THE GENERATOR, AND ATTENDANT | | | UTILITIES WILL NEED TO BE ON A RAISED PLATFORM, WITH | | | STAIRS AND GUARDRAIL AROUND THE TOTAL STRUCTURE. THE | | | LIFT STATION ITSELF WOULD REQUIRE DRY FLOOD PROOFING TO | | | A HEIGHT OF BFE + 1 FT. OR DFE WHICHEVER IS HIGHER, SEE | | | ASCE/ SEI 24-05 TABLE 6-1. | | | COMMENT: GENERATOR WILL BE A TRAILERABLE PORTABLE | | | GENSET | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-28 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-27 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2018-09-28 10:51:10 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 17080142 | | | 2ND REVIEW: SEPTEMBER 28, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | I CLEARED COMMENT #1 SINCE I LOCATED THE CONVERSION OF | | | NGVD29 TO NAVD88 ON G-3. | | | HOWEVER, THE REMAINING COMMENTS WERE NOT ADDRESSED. | | | THERE WAS NO COMMENT RESPONSE SHEET FOR FIRST REVIEW | | | BUILDING COMMENTS AND ONLY E-SHEETS WERE UPDATED. | | | PLEASE PROVIDE COMMENT RESPONSE SHEETS AND | | | UPDATED/CLOUDED SHEETS AS NEEDED TO ADDRESS THE | | | COMMENTS. | | | | | | | | | | | | 2017-08-22 15:57:40 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17080142 | | | ADD: 1100 N. FLAGLER DR. LIFT STATION # 20 (SANITARY | | | SEWER) | | | CONT: TBD/ TO BE DETERMINED | | | TEL: 561-801-3659 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. AUGUST 22, 2017 | | | ACTION: DENIED | | | | | | 1) OK. | | | | | | 2) THE 2ND ISSUE OR UNKNOWN IS WHEN THIS LIFT STATION | | | WAS BUILT TO DETERMINE IF IT IS A PRE-FIRM OR POST FIRM | | | STRUCTURE? PLEASE PROVIDE WHEN THIS STRUCTURE WAS | | | BUILT. | | | | | | 3) THE OTHER ISSUE TO DETERMINE TO WHAT EXTENT THIS | | | STRUCTURE HAS TO COMPLY IS WHAT DOLLAR AMOUNT IS THE | | | LIFT STATION, OR ANOTHER WORD HAS THE LIFT STATION HIT | | | THE 50% OF THE STRUCTURE VALUE AND NEED TO MEET THE | | | STANDARDS OF THE CURRENT CODE. | | | | | | 4) SHEET G-2 THE GENERAL NOTES DOES NOT LIST THE DESIGN | | | CRITERIA FOR THIS BUILDING. OCCUPANCY TYPE WOULD BE | | | UTILITY. IN THE SPECS THIS FACILITY IS LISTED AS A | | | FORCE MAIN AND IT WOULD BE ASSUMED TO BE A RISK | | | CATEGORY III STRUCTURE. SEE TABLE 1604.5 OF THE 2014 | | | FBC-B. THE QUESTION IS THIS BUILDING AND OPERATION TO | | | BE CONSIDERED A WASTE WATER TREATMENT FACILITY AND | | | OTHER PUBLIC UTILITY FACILITIES NOT INCLUDED IN RISK | | | CATEGORY IV, THE RISK CATEGORY WOULD BE A III. | | | | | | 5) 2014 FBC-B 1612.4 DESIGN AND CONSTRUCTION. THE | | | DESIGN AND CONSTRUCTION OF BUILDINGS AND STRUCTURES | | | LOCATED IN FLOOD HAZARD AREAS, INCLUDING COASTAL HIGH | | | HAZARD AREAS, SHALL BE IN ACCORDANCE WITH CHAPTER 5 OF | | | ASCE 7 AND WITH ASCE 24. PLEASE REVIEW IN THE ASCE/ SEI | | | 24-05 THE DEFINITION FOR COASTAL A ZONE. | | | COASTAL A ZONE. IN A COASTAL A ZONE, THE PRINCIPLE | | | SOURCES OF FLOODING MUST BE ASTRONOMICAL HIGH TIDES, | | | STORM SURGE, SEICHES OR TSUNAMIS. DURING THE BASE FLOOD | | | CONDITIONS, THE POTENTIAL FOR BREAKING WAVE HEIGHTS | | | SHALL BE GREATER THAN OR EQUAL TO 1.5 FEET. PLEASE | | | REVIEW ASCE/ SEI TABLE 4-1 AND THE REQUIRED HEIGHT | | | ABOVE EITHER THE BASE FLOOD OR THE DFE. ON THE NEW MAPS | | | NOT ADOPTED AS OF THIS REVIEW THE DESIGN FLOOD | | | ELEVATION, THE DESIGN FLOOD, INCLUDING WAVE HEIGHT, | | | RELATIVE TO THE DATUM SPECIFIED ON THE COMMUNITY?S | | | FLOOD HAZARD MAP. THERE ARE 2 HEIGHTS GIVEN WHEN THE | | | MEMBER ORIENTATION RELATIVE TO THE DIRECTION OF THE | | | WAVE APPROACH: | | | PARALLEL BFE + 1 FT. OR DFE WHICHEVER IS HIGHER. | | | PERPENDICULAR BFE + 2 FT. OR DFE, WHICHEVER IS HIGHER. | | | | | | PLEASE NOTE FROM THE CITY OF WEST PALM BEACH SUMMARY OF | | | COASTAL STILLWATER STUDY TABLE 9 FOR THIS SECTION OF | | | THE INTERCOASTAL WATER WAY GIVEN IN NAV88 IS 7.3 FT. | | | | | | IT WOULD APPEAR THAT THE GENERATOR, AND ATTENDANT | | | UTILITIES WILL NEED TO BE ON A RAISED PLATFORM, WITH | | | STAIRS AND GUARDRAIL AROUND THE TOTAL STRUCTURE. THE | | | LIFT STATION ITSELF WOULD REQUIRE DRY FLOOD PROOFING TO | | | A HEIGHT OF BFE + 1 FT. OR DFE WHICHEVER IS HIGHER, SEE | | | ASCE/ SEI 24-05 TABLE 6-1. | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-08-22 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-08-22 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2017-08-22 15:57:40 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17080142 | | | ADD: 1100 N. FLAGLER DR. LIFT STATION # 20 (SANITARY | | | SEWER) | | | CONT: TBD/ TO BE DETERMINED | | | TEL: 561-801-3659 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. AUGUST 22, 2017 | | | ACTION: DENIED | | | | | | 1) PLEASE NOTE AT THIS TIME A THOROUGH REVIEW CANNOT BE | | | ACHIEVED THERE ARE TOO MANY VARIABLES. | | | THIS LIFT STATION AND ATTENDANT UTILITIES IS LOCATED IN | | | AN A5 FLOOD ZONE. THE SHEET C-3 INDICATES THE TOP OF | | | THE GENERATOR SLAB IS TO BE 4.75 FT. FOR LIFT STATION # | | | 20. SHEET G-3 NOTE 13 AND 14 FOR BOTH LIFT STATIONS, | | | LIFT STATION # 20 & 89 BOTH ELEVATIONS ARE GIVEN IN | | | NGVD 29. THE CITY OF WEST PALM BEACH BUILDING | | | DEPARTMENT IS USING NGVD 29 UNTIL THE NEW FLOOD MAPS | | | ARE ADOPTED. PLEASE PROVIDE THE ELEVATIONS IN BOTH | | | STANDARDS DURING THIS TRANSITION PERIOD. THANK YOU. | | | | | | 2) THE 2ND ISSUE OR UNKNOWN IS WHEN THIS LIFT STATION | | | WAS BUILT TO DETERMINE IF IT IS A PRE-FIRM OR POST FIRM | | | STRUCTURE? PLEASE PROVIDE WHEN THIS STRUCTURE WAS | | | BUILT. | | | | | | 3) THE OTHER ISSUE TO DETERMINE TO WHAT EXTENT THIS | | | STRUCTURE HAS TO COMPLY IS WHAT DOLLAR AMOUNT IS THE | | | LIFT STATION, OR ANOTHER WORD HAS THE LIFT STATION HIT | | | THE 50% OF THE STRUCTURE VALUE AND NEED TO MEET THE | | | STANDARDS OF THE CURRENT CODE. | | | | | | 4) SHEET G-2 THE GENERAL NOTES DOES NOT LIST THE DESIGN | | | CRITERIA FOR THIS BUILDING. OCCUPANCY TYPE WOULD BE | | | UTILITY. IN THE SPECS THIS FACILITY IS LISTED AS A | | | FORCE MAIN AND IT WOULD BE ASSUMED TO BE A RISK | | | CATEGORY III STRUCTURE. SEE TABLE 1604.5 OF THE 2014 | | | FBC-B. THE QUESTION IS THIS BUILDING AND OPERATION TO | | | BE CONSIDERED A WASTE WATER TREATMENT FACILITY AND | | | OTHER PUBLIC UTILITY FACILITIES NOT INCLUDED IN RISK | | | CATEGORY IV, THE RISK CATEGORY WOULD BE A III. | | | | | | 5) 2014 FBC-B 1612.4 DESIGN AND CONSTRUCTION. THE | | | DESIGN AND CONSTRUCTION OF BUILDINGS AND STRUCTURES | | | LOCATED IN FLOOD HAZARD AREAS, INCLUDING COASTAL HIGH | | | HAZARD AREAS, SHALL BE IN ACCORDANCE WITH CHAPTER 5 OF | | | ASCE 7 AND WITH ASCE 24. PLEASE REVIEW IN THE ASCE/ SEI | | | 24-05 THE DEFINITION FOR COASTAL A ZONE. | | | COASTAL A ZONE. IN A COASTAL A ZONE, THE PRINCIPLE | | | SOURCES OF FLOODING MUST BE ASTRONOMICAL HIGH TIDES, | | | STORM SURGE, SEICHES OR TSUNAMIS. DURING THE BASE FLOOD | | | CONDITIONS, THE POTENTIAL FOR BREAKING WAVE HEIGHTS | | | SHALL BE GREATER THAN OR EQUAL TO 1.5 FEET. PLEASE | | | REVIEW ASCE/ SEI TABLE 4-1 AND THE REQUIRED HEIGHT | | | ABOVE EITHER THE BASE FLOOD OR THE DFE. ON THE NEW MAPS | | | NOT ADOPTED AS OF THIS REVIEW THE DESIGN FLOOD | | | ELEVATION, THE DESIGN FLOOD, INCLUDING WAVE HEIGHT, | | | RELATIVE TO THE DATUM SPECIFIED ON THE COMMUNITY?S | | | FLOOD HAZARD MAP. THERE ARE 2 HEIGHTS GIVEN WHEN THE | | | MEMBER ORIENTATION RELATIVE TO THE DIRECTION OF THE | | | WAVE APPROACH: | | | PARALLEL BFE + 1 FT. OR DFE WHICHEVER IS HIGHER. | | | PERPENDICULAR BFE + 2 FT. OR DFE, WHICHEVER IS HIGHER. | | | | | | PLEASE NOTE FROM THE CITY OF WEST PALM BEACH SUMMARY OF | | | COASTAL STILLWATER STUDY TABLE 9 FOR THIS SECTION OF | | | THE INTERCOASTAL WATER WAY GIVEN IN NAV88 IS 7.3 FT. | | | | | | IT WOULD APPEAR THAT THE GENERATOR, AND ATTENDANT | | | UTILITIES WILL NEED TO BE ON A RAISED PLATFORM, WITH | | | STAIRS AND GUARDRAIL AROUND THE TOTAL STRUCTURE. THE | | | LIFT STATION ITSELF WOULD REQUIRE DRY FLOOD PROOFING TO | | | A HEIGHT OF BFE + 1 FT. OR DFE WHICHEVER IS HIGHER, SEE | | | ASCE/ SEI 24-05 TABLE 6-1. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-18 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-18 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-16 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-16 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2017-08-16 10:16:56 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE AIC RATING OF THE SERVICE | | | EQUIPMENT, ATS, AND LIFT STATION CONTROL PANEL IS | | | ADEQUATE. NEC 110.9, 110.10, 409.110(4) | | | 2. PROVIDE AIC RATING OF SERVICE DISCONNECT, ATS, AND | | | LIFT STATION CONTROL PANEL. NEC 110.3, 110.9, | | | 409.110(4) | | | 3. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-09-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-09-04 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-08-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-08-15 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2017-08-15 15:20:22 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE NO INDICATIONS OF REVIEW AND/OR COMPLIANCE | | | WITH THE REQUIERMENTS OF NFPA 820, STANDARD FOR FIRE | | | PROTECTION IN WASTEWATER TREATMENT AND COLLECTION | | | FACILITIES, 2012 EDITION. | | | | | | COMBUSTIBLE GAS DETECTION SYSTEM AND NFPA 72 MONITORING | | | MAY BE REQUIRED. | | | | | | PLEASE PROVIDE A REVIEW TO INCLUDE BUT NOT LIMITED TO: | | | | | | 3.3.48* PUMPING STATION. A STRUCTURE THAT CONTAINS | | | PUMPS AND APPURTENANT PIPING, VALVES, AND OTHER | | | MECHANICAL AND ELECTRICAL EQUIPMENT FOR PUMPING | | | WASTEWATER OR OTHER LIQUID. | | | A.3.3.48 PUMPING STATION. ALSO CALLED LIFT STATION. | | | | | | 3.3.72 WELL. | | | 3.3.72.1* DRY WELL. THE PORTION OF A PUMPING STATION | | | DESIGNED TO PROVIDE ISOLATION AND SHELTER OR | | | ACCOMMODATIONS FOR CONTROLS OR EQUIPMENT ASSOCIATED | | | WITH PUMPING OF WASTEWATER AND DESIGNED TO COMPLETELY | | | AND PERMANENTLY EXCLUDE WASTEWATER OR | | | WASTEWATER-DERIVED ATMOSPHERES. | | | 3.3.72.2* WET WELL. THE PORTION OF THE PUMPING STATION | | | THAT RECEIVES AND TEMPORARILY STORES WASTEWATER FOR THE | | | PURPOSE OF PUMPING. | | | A.3.3.72.1 DRYWELL. DRY WELLS CAN CONTAIN ACCIDENTAL | | | LEAKAGE OF WASTEWATER FROM SHAFT SEALS OR OCCASIONAL | | | SPILLS. A DRY WELL COULD CONTAIN EQUIPMENT SUCH AS | | | PUMPS, MOTORS, FANS, WIRING, CONTROLS, LIGHTS AND | | | ASSOCIATED | | | WIRING DEVICES, AND OTHER ACCESSORIES. | | | A.3.3.72.2 WET WELL. A WET WELL MIGHT OR MIGHT NOT | | | CONTAIN ELECTRICAL EQUIPMENT SUCH AS PUMPS, MOTORS, | | | FANS, WIRING AND WIRING DEVICES, CONTROLS, LIGHTS, AND | | | OTHER ACCESSORIES. | | | | | | 4.2* DESIGN AND CONSTRUCTION. THE DESIGN AND | | | CONSTRUCTION OF COLLECTION SYSTEM FACILITIES SHALL | | | CONFORM TO TABLE 4.2, WHICH SUMMARIZES THE VARIOUS | | | COMPONENTS ASSOCIATED WITH WASTEWATER COLLECTION AND | | | TRANSPORT SYSTEMS. | | | | | | D.2.4.7 PUMPING STATIONS THAT HANDLE RAW WASTEWATER | | | SHOULD BE CLASSIFIED IN THE SAME MANNER AS WASTEWATER | | | PUMPING STATIONS (SEE CHAPTER 4). IN-PLANT PUMPING | | | STATIONS SHOULD BE CLASSIFIED ON THE BASIS OF THEIR | | | LOCATION IN THE PROCESS TRAIN AND THE TYPE OF MATERIAL | | | HANDLED. RESTRICTIVE CLASSIFICATIONS ARE GENERALLY NOT | | | NECESSARY FOR PUMPING STATIONS THAT HANDLE FULLY | | | TREATED WASTEWATER | | | | | | CHAPTER 7 FIRE AND EXPLOSION PREVENTION AND PROTECTION | | | | | | 7.1* SCOPE. THIS CHAPTER SHALL ESTABLISH MINIMUM | | | REQUIREMENTS FOR OVERALL PROTECTION AGAINST FIRE AND | | | EXPLOSION HAZARDS IN WASTEWATER FACILITIES AND | | | ASSOCIATED COLLECTION SYSTEMS. | | | 7.1.1 GASES, LIQUIDS, AND SOLIDS SHALL BE ASSIGNED TO | | | ONE OF THE FOLLOWING TWO CATEGORIES: | | | (1) FLAMMABLE/COMBUSTIBLE HAZARDS | | | (2) SAFETY AND HEALTH HAZARDS | | | 7.1.2 THIS STANDARD SHALL APPLY TO THE FLAMMABILITY | | | ASPECTS OF A PARTICULAR SUBSTANCE, PROCESS, OR AREA | | | WITHIN WASTEWATER AND COLLECTION FACILITIES. | | | 7.1.3 NFPA 70E AND NFPA 101? SHALL BE REFERENCED FOR | | | ADDITIONAL REQUIREMENTS TO PROTECT AGAINST SAFETY AND | | | HEALTH HAZARDS. | | | 7.2 FIRE PROTECTION MEASURES. | | | 7.2.1 GENERAL. | | | 7.2.1.1 COLLECTION SYSTEMS, LIQUID STREAM TREATMENT | | | PROCESSES, AND SOLIDS-HANDLING PROCESSES SHALL BE | | | PROVIDED WITH FIRE PROTECTION FOR THE FIRE HAZARDS, AS | | | DESCRIBED IN TABLE 4.2, TABLE 5.2, TABLE 6.2(A), AND | | | TABLE 6.2(B). | | | 7.2.1.2 ENCLOSED SPACES CLASSIFIED AS EXPLOSION HAZARD | | | AREAS UNDER THIS DOCUMENT SHALL BE PHYSICALLY SEPARATED | | | FROM ALL UNCLASSIFIED ENCLOSURES. | | | 7.2.1.3 IN ADDITION TO THE FIRE PROTECTION SPECIFIED IN | | | CHAPTER 8, BUILDINGS, STRUCTURES, AND PROCESS ELEMENTS, | | | UNDER SOME CONDITIONS, SHALL BE PROVIDED WITH | | | AUTOMATIC-EXTINGUISHING SYSTEMS IN ACCORDANCE WITH THIS | | | CHAPTER. | | | | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-11-19 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-10-22 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-10-10 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-08-29 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-08-31 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-08-31 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-08-02 |
Time |
12:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-08-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-08-22 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-08-22 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2018-11-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-11-09 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-11-09 |
Time |
17:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2017-08-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-21 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-21 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2017-08-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-08-21 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-21 |
Time |
16:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
X |
PERMIT EXTENSION |
| Rev No |
1 |
Status |
N |
Date |
2018-03-01 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2018-03-01 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2018-03-01 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2018-03-01 14:46:43 | REVIEWED AND ACCEPTED 2/12/18 LETTER FROM LUIS PEREZ | | | REQUESTING A 90 DAY EXTENSION OF THE PERMIT APPLICATION | | | BECAUSE THE ORDER OF PRIORITY OF CAPITAL IMPROVEMENT | | | PROJECTS WAS CHANGED. EXTENSION GRANTED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-11-19 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-11-19 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-10-09 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-10-09 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-10-09 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2018-10-09 16:38:48 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 10.09.2018 | | | PERMIT NO.: 17080142 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. A SEPARATE LANDSCAPE PERMIT SHALL BE OBTAINED FOR | | | ALL LANDSCAPE SCREENING, AS APPROVED BY RESOLUTION NO. | | | 184-17 AND THE FACE-OF-THE-CITY PRESENTATION BEFORE THE | | | CITY COMMISSION ON JUNE 5, 2017. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-08-31 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-08-31 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-08-31 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2017-08-31 11:48:11 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 08.31.2017 | | | PERMIT NO.: 17080142 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. A SEPARATE LANDSCAPE PERMIT SHALL BE OBTAINED FOR | | | ALL LANDSCAPE SCREENING, AS APPROVED BY RESOLUTION NO. | | | 184-17 AND THE FACE-OF-THE-CITY PRESENTATION BEFORE THE | | | CITY COMMISSION ON JUNE 5, 2017. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |