Plan Review Details - Permit 17071275
| Plan Review Stops For Permit 17071275 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-08-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-07 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-07 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-04 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-04 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2017-08-04 09:44:24 | RESIDENTIAL (R3) ELEVATION CERTIFICATE BUILDING REVIEW | | | COMMENTS. | | | | | | 1- FINAL EQUIPMENT ELEVATION SHOWN ON PAGE 2 OF 6 | | | DOESN'T COMPLY WITH THE CITY CODE SEC. 94-546(B)(1). | | | BASED ON THE PERMIT APPLICATION, THE ELEVATION NEED TO | | | BE AT LEAST 6" ABOVE THE BASE FLOOD ELEVATION. THE BASE | | | FLOOD ELEVATION FOR FLOOD ZONE A5 IS 7'-0". THEREFORE, | | | EQUIPMENT NEEDS TO BE ELEVATED AND RE-INSPECTION IS | | | REQUIRED. | | | | | | 2- ITEM #C2(B) ON PAGE 2 OF 6 NEEDS TO BE COMPLETED. | | | THIS IS A TWO STORY RESIDENCE. NA IS INCORRECT. SEC. | | | 107.2.1 CITY AMENDMENTS. SEC. R322 FBC-RESIDENTIAL. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-08-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-07 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-07 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2017-08-07 12:16:20 | REVISED ELEVATION CERTIFICATE SUBMITTED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-08-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-04 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-07-31 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2017-08-01 13:40:18 | SUBMITTAL ROUTED TO JGOMEZ |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-08-04 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-08-04 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-08-04 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2017-08-04 13:45:40 | MEAN HEIGTH OK |
|
|
|