Plan Review Details - Permit 17071224
| Plan Review Stops For Permit 17071224 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-08-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-21 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-21 |
Time |
07:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-02 |
Time |
07:19 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-02 |
Time |
07:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-08-17 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2017-08-18 12:52:18 | RESUB ROUTED TO JPEARSON'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-08-11 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2017-08-14 17:26:08 | CCOLES DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-07-31 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-08-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-21 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-21 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2017-08-21 10:07:20 | MECHANICAL PROVISO: | | | | | | SEPARATE PERMITS ARE REQUIRED FOR THE ROTARY OVEN | | | EXHAUST, AND THE WALK-IN COOLER AND FREEZER. | | | | | | CCOLE- 8/21/17 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-08-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-15 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-15 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2017-08-15 12:23:42 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17071224 | | | 8/15/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M0.1: THE BUILDING PRESSURIZATION TABLE IS | | | INCORRECTLY INDICATING NEUTRAL PRESSURE, HOWEVER IT | | | SHOULD READ -200. PLEASE CORRECT AND PROVIDE THE MAKE | | | UP AIR FOR THE ROTARY OVEN IN THE CALCULATION TABLE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-09 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-09 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2017-08-09 09:19:04 | 1ST REVIEW FBC-2014 MECHANICAL | | | REVISION PERMIT #17071224 | | | 8/9/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SUBMIT AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW 2.5 TON AC SYSTEM- SECTION C403.2.1 FBC-14 ENERGY | | | CONSERVATION. | | | | | | 2) REVISE THE ENERGY COMPLIANCE FORM TO INCLUDE THE NEW | | | AC SYSTEM. | | | | | | 3) SHEET M0.1: PLEASE PROVIDE THE BUILDING | | | PRESSURIZATION AND KITCHEN EXHAUST TABLES THAT ARE | | | MISSING FROM THE REVISED PLAN SHEET. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-08-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-08-03 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-03 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
|