Plan Review Details - Permit 17071106
| Plan Review Stops For Permit 17071106 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-08-31 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2017-08-31 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2017-08-31 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2017-08-31 11:22:41 | PERMIT VALUATION COMMENT ADDRESSED AS FOLLOWS. | | | CONTRACTOR OBTAINED A SEPARATE DEMOLITION PERMIT # | | | 17071106 WITH A PERMIT FEE BASED ON THE STATED VALUE OF | | | $8,000 FOR THAT SCOPE OF WORK. THE $52,000 VALUE STATED | | | FOR THIS REMODEL PERMIT EXCLUDES THE DEMOLITION AND THE | | | CONTRACTOR PROVIDED A BREAKDOWN SHOWING THAT THE JOB | | | WILL BE BILLED TO THE OWNER ON A TIME AND MATERIALS | | | BASIS. THE BREAKDOWN SHOWED THE HOURLY RATES FOR THE | | | PERSONNEL WHO WILL WORK ON THE PROJECT. OK TO ACCEPT | | | STATED VALUE. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6652 ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-02 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-02 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2017-08-02 16:26:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FBC 109, VALUE TO INCLUDE LABOR, MATERIALS, | | | OVERHEAD, PROFIT, INCLUDING ITEMS PROVIDED BY OTHERS. | | | PROVIDE A COPY OF THE CONTRACT VIA EMAIL. PLANS HAVE | | | BEEN STAMPED AND APPEAR CODE COMPLIANT. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-02 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-02 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-08-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-08-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-08-03 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2017-08-04 10:49:44 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) THE COVER SHEET INDICATES "THIS BUILDING IS | | | NON-SPRINKLED CONDOMINIUM" AND IS INCORRECT. THE | | | BUILDING IS SPRINKLERED. THE FIRE SPRINKLER SYSTEM | | | SHALL BE MAINTAINED THROUGHOUT CONSTRUCTION. | | | | | | ANY AND ALL WORK ON THE FIRE SPRINKLER SYSTEM SHALL BE | | | DONE UNDER SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE | | | SAFETY CONTRACTORS. | | | | | | | | | 2) ANY WORK ON FIRE ALARM EQUIPMENT SHALL BE DONE UNDER | | | SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY | | | CONTRACTORS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-09-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-08-31 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2017-09-01 09:40:20 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-08-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-08-11 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-27 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-09-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-09-07 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-09-07 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-09 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-09 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2017-08-09 12:40:42 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17071106 | | | 8/8/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A SCOPE OF WORK FOR MECHANICAL ALTERATIONS | | | WITH CORRESPONDING DRAWINGS AND DETAILS ON THE PLANS. | | | | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE NEW | | | RANGE AND EXHAUST HOOD- SEE SECTION 505. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-08-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-08-11 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-11 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
|