Plan Review Details - Permit 17071087
| Plan Review Stops For Permit 17071087 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-01-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-05 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-05 |
Time |
07:16 |
Sent To |
I |
|
| Notes |
| 2018-01-05 12:13:27 | ****PROVISO**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FROM PREVIOUS LIST: | | | | | | 4. DETAIL 1-S1.0 SPECS SELF DRILLING SCREWS PER | | | MANUFACTURER REQUIREMENTS. DETAIL 2-M2 ALSO REFERS TO | | | MANUFACTURER INSTRUCTIONS. FBC B 1609, REVISE DETAILS | | | TO SPECIFY FASTENING INCLUDING DIAMETER, LENGTH, | | | FASTENING PATTERN. IF THIS WILL BE DELEGATED | | | ENGINEERING PER FLORIDA ADMINISTRATIVE CODE 61G15-30, | | | PROVIDE THE DELEGATED ENGINEERING (UNIT FASTENING TO | | | CURB, ANY OTHER ) AT THIS TIME. STRUCTURAL ENGINEER OF | | | RECORD (SEOR) TO REVIEW DELEGATED ENGINEERING PRIOR TO | | | SUBMITTAL. | | | | | | DETAIL WAS NOT REVISED BUT A NEW NOTE REFERS TO THIS AS | | | "DELEGATED ENGINEERING". SUBJECT TO INSPECTOR'S | | | DISCRETION, A REVISION MAY BE REQUIRED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-02 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-02 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2017-08-02 16:07:16 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FS489, CLARIFY SCOPE OF WORK FOR WADMAN FABRICATORS. | | | I WAS UNABLE TO FIND A LICENSE NUMBER FOR THIS COMPANY | | | ON DBPR WEBSITE. WILL THIS WORK BE DONE ON SITE OR OFF | | | SITE? | | | | | | 2. S1.0, FBC B TABLE 1607.1(26), ALL ROOF SURFACES | | | SUBJECT TO MAINTENANCE WORKERS TO BE DESIGNED TO A 300# | | | LIVE LOAD, 20# SPECIFIED, CLARIFY OR REVISE. | | | | | | 3. THIS APPEARS TO BE LOCATED IN EXPOSURE C, SEE FBC | | | 1609.4, SEE ALSO ASCE7-10 AND COMMENTARY. THE LARGE | | | OPEN SPACE (PARKING LOT) CREATES A PATCH CONDITION IN | | | THAT DIRECTION, THE AREA TO THE NORTH AND AREA TO THE | | | NORTHWEST ARE OPEN; REVISE PLAN (AND DESIGN, IF | | | NECESSARY) TO EXPOSURE C OR EMAIL RATIONALE FOR | | | EXPOSURE B VIA EMAIL PRIOR TO RESUBMITTAL. | | | | | | 4. DETAIL 1-S1.0 SPECS SELF DRILLING SCREWS PER | | | MANUFACTURER REQUIREMENTS. DETAIL 2-M2 ALSO REFERS TO | | | MANUFACTURER INSTRUCTIONS. FBC B 1609, REVISE DETAILS | | | TO SPECIFY FASTENING INCLUDING DIAMETER, LENGTH, | | | FASTENING PATTERN. IF THIS WILL BE DELEGATED | | | ENGINEERING PER FLORIDA ADMINISTRATIVE CODE 61G15-30, | | | PROVIDE THE DELEGATED ENGINEERING (UNIT FASTENING TO | | | CURB, ANY OTHER ) AT THIS TIME. STRUCTURAL ENGINEER OF | | | RECORD (SEOR) TO REVIEW DELEGATED ENGINEERING PRIOR TO | | | SUBMITTAL. | | | | | | OTHER STRUCTURAL SPECS ARE ALSO TOO GENERAL TO SHOW | | | COMPLIANCE WITH FBC B 1609, RESISTANCE TO WIND LOADS. | | | FOR INSTANCE, 1-M2 REFERS TO "HOLD DOWN BRACKETS". | | | | | | 5. SOME PAGES ARE NOT SIGNED AND SEALED IN ACCORDANCE | | | WITH FLORIDA STATUTE 471. PRIOR TO RESUBMITTAL, VERIFY | | | THAT ALL PAGES INCLUDE AN ORIGINAL "WET" SIGNATURE. FOR | | | INSTANCE, SEE STRUCTURAL PAGES (NOT ORIGINAL SIGNATURE, | | | WAS DIGITALLY SIGNED AND SEALED). CHECK ALL PAGES PRIOR | | | TO RESUBMITTAL. | | | | | | 6. TITLE BLOCK FOR DONALD C. CARROLL, PE IS NOT CLEAR. | | | SEE FS471, FAC61G15-23.002. REVISE S1.0 TO INCLUDE OR | | | CLARIFY. | | | | | | 7. SEE FLORIDA STATUTE 471.0195; THE DBPR WEBSITE | | | (MYFLORIDALICENSE.COM) DOES NOT REFLECT THAT THE | | | FOLLOWING HAVE TAKEN THE ADVANCED FLORIDA BUILDING CODE | | | COURSE. PLEASE SEND EVIDENCE THAT THE COURSE WAS | | | COMPLETED TO FBPE AND REQUEST THAT THEY UPDATE THE | | | WEBSITE. THIS COURSE IS DUE WITHIN ONE YEAR AFTER THE | | | ADOPTION OF THE FBC (WAS DUE JUNE 30, 2016). | | | | | | JASON M. SCATES, PE | | | RICKY N TERRELL, PE | | | RANDALL C. HAASE, PE | | | | | | THIS WILL NOT DELAY PERMIT ISSUANCE. | | | | | | 8. FBC 109, VALUE TO INCLUDE LABOR, MATERIALS, | | | OVERHEAD, PROFIT, INCLUDING ITEMS PROVIDED BY OTHERS. | | | PLAN NOTES THAT SOME ITEMS WILL BE PROVIDED BY WALMART; | | | VERIFY THAT THE VALUE OF THOSE ITEMS ARE INCLUDED IN | | | PERMIT VALUE. | | | | | | 9. SHEETS S1.1 THROUGH S4.0 ARE BLANK; PLEASE REMOVE, | | | FBC 107. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-12-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-28 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-28 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-08-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-01 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-01 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2017-08-01 10:04:41 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL SPECS FOR ALL NEW EQUIPMENT TO BE | | | INSTALLED INCLUDING MINIMUM CIRCUIT AMPACITY | | | REQUIREMENTS AND MAXIMUM OVERCURRENT PROTECTION | | | REQUIRED PER MANUFACTURER. NEC 110.3; FBC 107.2.1 | | | 2. PROVIDE VOLTAGE DROP CALCULATIONS FOR EACH BRANCH | | | CIRCUIT TO ANY NEW EQUIPMENT INSTALLED. ALTHOUGH NOT | | | SUPPLIED WITH THE AMPACITY REQUIREMENTS NOTED IN | | | COMMENT #1, AN ESTIMATED VOLTAGE DROP CALCULATION SHOWS | | | THAT SOME EXISTING WIRING APPEARS TO NOT BE SIZED | | | ADEQUATELY TO COMPLY WITH FBC ENERGY CODE. PROVIDE | | | CORRECTIONS AS NECESSARY SO THAT CONDUCTORS ARE SIZED | | | FOR A MAXIMUM VOLTAGE DROP OF 3%. FBC C405.7.3.2, FBC | | | 107.2.1 | | | 3. SHEET E1, RTU SCHEDULE, SHOWS A DIFFERENT VALUE FOR | | | THE REQUIRED OCPD AND THE EXISTING OCPD. THE BRANCH | | | CIRCUIT OVERCURRENT PROTECTION DEVICE RATING SHALL BE | | | THE SIZE AND TYPE MARKED ON THE EQUIPMENT. NEC 110.3, | | | 440.22(C) | | | 4. SHEET RE3, CASE DEFROST DETAIL, STATES THAT B PHASE | | | IS A HIGH LEG, BUT ALSO STATES THAT THIS IS A 208 VOLT | | | SYSTEM WHICH DOES NOT HAVE A HIGH LEG. PLEASE CLARIFY | | | AND/OR CORRECT. FBC 107.2.1 | | | 5. PROVIDE PANEL SCHEDULE FOR ANY PANEL AFFECTED BY | | | PROPOSED WORK. INCLUDE DETAILS OF WIRING AND BREAKER | | | SIZE FOR NEW AND ALTERED CIRCUITS. INCLUDE TOTAL LOAD | | | CALCULATED FOR PANEL TO CONFIRM THE CAPACITY OF PANEL | | | IS SUFFICIENT TO SUPPLY LOADS. NEC 215.5, 408.4, | | | 408.30; FBC 107.2.1, 107.3.5 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-12-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-12-20 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-12-20 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2017-12-20 14:15:07 | I HAVE REVIEWED THE RESPONSE LETTER DATED AUG. 10, 2017 | | | FROM MS. SHERRY BROWN OF GLOBAL SECURITY. THE LETTER | | | INDICATES 3 REASONS WHY FIRE ALARM NOTIFICATION | | | APPLIANCES ARE NEEDED; HOWEVER, NONE OF THE REASONS ARE | | | SUPPORTED BY NFPA 72. IF THE FIRE INSPECTOR FIELD | | | RESULTS INDICATE LOW AUDIBILITY IN THE NEW FREEZERS, | | | THEN TO MEET THE AUDIOBILITY REQUIREMENTS OF NFPA 72, | | | TYPICALLY FIRE ALARM NOTIFICATION DEVICES WILL BE | | | REQUIRED IN THESE LARGE COOLERS. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-08-02 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-08-02 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2017-08-02 11:03:25 | TO MEET THE AUDIOBILITY REQUIREMENTS OF NFPA 72, | | | TYPICALLY FIRE ALARM NOTIFICATION DEVICES WILL BE | | | REQUIRED IN THESE LARGE COOLERS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-01-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-05 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-12-12 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-07-27 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-12-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-12-21 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-12-21 |
Time |
15:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-09 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-09 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2017-08-09 08:45:44 | 1ST REVIEW FBC-2014 MECHANICAL , EXISTING BUILDING, & | | | ENERGY CONSERVATION CODES. | | | PERMIT #17071087 | | | 8/9/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET R3: REFER TO SECTION 1104.2 AND INDICATE THE | | | AMOUNT OF REFRIGERANT IN EACH CIRCUIT. | | | | | | 2) REM2: CLARIFY IF EMERGENCY VENTILATION WILL BE | | | PROVIDED AT LEAK DETECTION ALARM LOCATIONS. | | | | | | 3) PROVIDE REFRIGERANT PIPING SPECIFICATIONS- SECTION | | | 1107.5. | | | | | | 4) PROVIDE SUBMITTALS FOR THE LEAK DETECTORS, PIPING | | | INSULATION, AND PIPING PENETRATION SEALANTS. PLEASE | | | NOTE THAT ALL SUBMITTALS SHALL BE APPROVED BY THE | | | ENGINEER OF RECORD. | | | | | | 5) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR ALL | | | NEW RTU'S- SECTION C403.2.1 FBC-14 ENERGY CONSERVATION. | | | | | | 6) PROVIDE DUCT SMOKE DETECTORS IN THE RETURN AIR | | | SYSTEMS OF ALL NEW AND REPLACED RTU'S- SECTION 606.2.1. | | | PLEASE NOTE THIS REQUIREMENT WILL BE WAIVED IF | | | MANUFACTURER'S SPECIFICATIONS INDICATE THE UNITS ARE | | | NOT CAPABLE OF SUPPLYING OVER 2000 CFMS OF AIR. | | | | | | 7) REFER TO TABLE 403.3 AND PROVIDE MINIMUM VENTILATION | | | CALCULATIONS FOR ALL NEW ROOMS AND SPACES. | | | | | | 8) THE PLAN IS SPECIFYING "NEW" AND "REPLACED" RTU'S. | | | PROVIDE STRUCTURAL ENGINEERING FOR THE ROOF OPENINGS | | | AND SUPPORTS FOR THE NEW RTU'S. | | | | | | 9) M2: SUBMIT THE LENNOX BRACKET SPECIFICATIONS WITH | | | APPROVAL STAMP BY THE ENGINEER OF RECORD. THE EOR SHALL | | | SPECIFY HOW MANY BRAQCKETS AND SCREWS ARE REQUIRED PER | | | WIND LOAD CALCULATIONS- SECTION 301.15. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|