Plan Review Details - Permit 17070891
| Plan Review Stops For Permit 17070891 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-25 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-09-25 |
Time |
17:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-10-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-19 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-19 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-09-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-27 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-27 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2017-09-27 06:56:19 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROJECT SUMMARY REFERENCES THE 2009 NEC, WHICH DOES | | | NOT EXIST. THE CURRENT ELECTRICAL CODE IS THE 2011 NEC. | | | PROVIDE CORRECTION. FBC PREFACE. | | | 2. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY PERSON RESPONSIBLE FOR THE DESIGN. FS 471, | | | 481; FBC 107.2.1, 107.3.5 | | | 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-08-30 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2017-08-30 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2017-08-30 |
Time |
14:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-10-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-19 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-16 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2017-10-17 15:18:39 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-09-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-27 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-25 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2017-08-28 13:07:17 | B11 | | 2017-07-28 09:55:07 | 17070891 | | | | | | 1ST REVIEW: FBC 2014 5TH ED. | | | 1ST REVIEW FBC 2014 EXISTING BUILDING | | | | | | APPLICATION DEEMED DEFICIENT. INFORMED CONTRACTOR. | | | | | | NEED SITE PLAN, ARCHITECTURAL DETAILS AND CODE | | | INFORMATION TO DETERMINE SCOPE OF WORK. | | | | | | 553.792?BUILDING PERMIT APPLICATION TO LOCAL | | | GOVERNMENT.? | | | (1)?WITHIN 10 DAYS OF AN APPLICANT SUBMITTING AN | | | APPLICATION TO THE LOCAL GOVERNMENT, THE LOCAL | | | GOVERNMENT SHALL ADVISE THE APPLICANT WHAT INFORMATION, | | | IF ANY, IS NEEDED TO DEEM THE APPLICATION PROPERLY | | | COMPLETED IN COMPLIANCE WITH THE FILING REQUIREMENTS | | | PUBLISHED BY THE LOCAL GOVERNMENT. | | | | | | | | | STEVEN KENNEDY, CBO | | | ASSISTANT BUILDING OFFICIAL | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-09-07 |
|
|
Cont ID |
|
| Sent By |
escheide |
Date |
2017-09-07 |
Time |
16:13 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2017-09-07 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2017-09-07 16:13:51 | NO INCREASE IN SQUARE FOOTAGE. |
|
|
|
Account Summary | Usage Policy | Privacy Policy