Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-08-14 Cont ID  
Sent By pleduc Date 2017-08-14 Time   Rev Time 0.00
Received By pleduc Date 2017-08-14 Time 10:49 Sent To PC
Notes
2017-08-14 13:03:34THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) PROVIDE AN EXIT SIGN ON THE GATE LEADING TO OUT TO
 SIDEWALK.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-07-25 Cont ID  
Sent By pleduc Date 2017-07-25 Time   Rev Time 0.00
Received By pleduc Date 2017-07-24 Time 16:46 Sent To PC
Notes
2017-07-25 13:15:25THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE ARE NO INDICATIONS OF EXISTING FIRE HYDRANTS
 AND/OR FDC LOCATION THAT MAY BE AFFECTED BY THE
 PROPOSED LOCATION.
  
 FIRE HYDRANTS AND FDC'S SHALL NO BE BLOCKED BY THE
 INSTALLATION AND ACCESSIBLE AT ALL TIMES.
  
 PLEASE INDICATE AND ACCOUNT FOR ACCESSIBLILTY.
  
  
  
 2) THERE ARE NO INDICATIONS OF GATES OR ACCESS POINTS.
 GATES SHALL HAVE KNOX PADLOCK PROVIDED FOR 24 HR
 EMERGENCY ACCESS.
  
 PLEASE PROVIDE.
  
  
  
 3) THE EXISTING SCHOOL HAS REQUIRED EXITS AND ACCESS TO
 PUBLIC WAYS. THERE ARE NO INDICATIONS THAT THE PUBLIC
 WAY ACCESS IS PROVIODED WITH THE PROPOSED. THE PROPOSED
 DETAIL REMOVES PUBLIC WAY ACCESS.
  
 PLEASE INDICATED HOW AND WHERE THE EXISTING EXIT PUBLIC
 WAY ACCESS IS MAINTAINED.
  
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-08-24 Cont ID  
Sent By cpuell Date 2017-08-24 Time 11:18 Rev Time 0.00
Received By cpuell Date 2017-08-10 Time 10:26 Sent To  
Notes
2017-08-11 10:26:26RESUB ROUTED TO LLOUIE VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-25 Cont ID  
Sent By pleduc Date 2017-07-25 Time   Rev Time 0.00
Received By pleduc Date 2017-07-21 Time 09:45 Sent To  
Notes
2017-07-24 09:45:31ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 2 Status P Date 2017-08-11 Cont ID  
Sent By llouie Date 2017-08-11 Time   Rev Time 0.00
Received By llouie Date 2017-08-11 Time   Sent To FIRE
Notes
2017-08-11 16:04:24ZONING APPROVED WITH THE FOLLOWING PROVISOS:
  
 1.) TEMPORARY CONSTRUCTION FENCE SHALL BE MAINTAINED IN
 A SATISFACTORY MANNER BY THE PERMITTEE/LANDOWNER.
  
 2.) GATES SHALL BE CHAINED WITH A LOCK SUBSTANTIAL
 ENOUGH TO ENSURE CLOSURE AND SECURITY WHEN WORKERS ARE
 NOT ON THE JOB.
  
  
  
  
  
2017-08-11 15:25:45ROUTED TO LINDA LOUIE

Review Stop Z ZONING
Rev No 1 Status F Date 2017-07-24 Cont ID  
Sent By llouie Date 2017-07-24 Time   Rev Time  
Received By llouie Date 2017-07-24 Time   Sent To FIRE
Notes
2017-07-24 15:16:48** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) HIGHLIGHT THE LOCATION OF THE CONSTRUCTION FENCE
 FOR BETTER VISIBILITY IN THE PLANS.
  
 2.) SHOW THE LOCATION OF THE ACCESS GATE.
  
 3.) PROVIDE SCREENING DETAILS. WIND SCREENING SHALL BE
 SUBSTANTIAL ENOUGH TO AVOID RIPS OR TEARS DUE TO WIND
 OR SUN, AND SHALL HAVE NO LESS THAN 85 PERCENT OPACITY.
 [ZLDR S.94-316(D)(2)]
  
 4.) THE PROPOSED TEMPORARY CONSTRUCTION FENCE SHALL NOT
 BE LOCATED WITHIN THE VISIBILITY TRIANGLE. THE
 VISIBILITY TRIANGLE BEGINS AT THE POINT WHERE THE
 PROPERTY LINES MEET AT THE CORNER, THEN 20 FT. ALONG
 THE FRONT PROPERTY LINE, THENCE DIAGONALLY TO A POINT
 ALONG THE SIDE PROPERTY LINE 20 FT. FROM THE POINT OF
 BEGINNING. PLEASE DEMONSTRATE COMPLIANCE. [ZLDR
 S.94-305(E)]
  
  
 NOTES:
  
 * ALL TEMPORARY CONSTRUCTION FENCING SHALL BE
 MAINTAINED IN A SATISFACTORY MANNER BY THE
 PERMITTEE/LANDOWNER AT ALL TIMES.
  
 * GATES SHALL BE CHAINED WITH A LOCK SUBSTANTIAL ENOUGH
 TO ENSURE CLOSURE AND SECURITY WHEN WORKERS ARE NOT ON
 THE JOB SITE.
  
 * REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
  
  
  
  
  
  
  
2017-07-24 14:05:06ROUTED TO LINDA LOUIE


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved