Plan Review Details - Permit 17070801
| Plan Review Stops For Permit 17070801 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-10-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-10-25 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-10-25 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-09-26 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-09-26 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2017-09-26 11:34:29 | PLAN | | | REVIEW COMMENTS | | | | | | 3RD REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) (PREVIOUS COMMENT) THE PRODUCT APPROVAL THAT WAS | | | SUBMITTED FOR THE BUILT UP ROOF (NOA NO.:14-1030.01) | | | WILL REQUIRE ENHANCED FASTENING IN ORDER TO MEET THE | | | UPLIFT PRESSURES FOR ROOF ZONES 2 AND 3. THE FASTENING | | | OPTION THAT YOU INDICATED ON PAGE 15 OF THE NOA HAS A | | | MAXIMUM DESIGN PRESSURE OF -52.5 PSF. THE REQUIRED | | | UPLIFT PRESSURES FOR ZONE 2 IS -63.6 PSF AND FOR ZONE 3 | | | IS -95.7 PER SHEET S.3 OF THE APPROVED PLANS. SEE | | | LIMITATION NUMBER 7 ON PAGE 31 AND SUBMIT TWO SETS OF | | | SIGNED AND SEALED RAS 117 CALCULATIONS FOR ENHANCED | | | FASTENING FOR THE PERIMETER AND CORNER AREAS OF THE | | | ROOF. FBC - R301.2.1 | | | | | | 2) (PREVIOUS COMMENT) THE RAS 117 CALCULATIONS THAT | | | WERE SUBMITTED ARE BASED ON NOA NO.13-1022.15 WHICH HAS | | | BEEN SUPERCEDED BY NOA NO. 14-1030.01. THE SYSTEM AND | | | FASTENING OPTION THAT YOU INDICATED ON THE PRODUCT | | | APPROVAL THAT WAS SUBMITTED DOES NOT MATCH THE | | | CALCULATIONS. PLEASE SUBMIT MATCHING DOCUMENTS. FBC | | | 107.2.1 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-08-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-08-22 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-08-22 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2017-08-22 15:25:57 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) (PREVIOUS COMMENT) THE PRODUCT APPROVAL THAT WAS | | | SUBMITTED FOR THE BUILT UP ROOF (NOA NO.:14-1030.01) | | | WILL REQUIRE ENHANCED FASTENING IN ORDER TO MEET THE | | | UPLIFT PRESSURES FOR ROOF ZONES 2 AND 3. THE FASTENING | | | OPTION THAT YOU INDICATED ON PAGE 15 OF THE NOA HAS A | | | MAXIMUM DESIGN PRESSURE OF -52.5 PSF. THE REQUIRED | | | UPLIFT PRESSURES FOR ZONE 2 IS -63.6 PSF AND FOR ZONE 3 | | | IS -95.7 PER SHEET S.3 OF THE APPROVED PLANS. SEE | | | LIMITATION NUMBER 7 ON PAGE 31 AND SUBMIT TWO SETS OF | | | SIGNED AND SEALED RAS 117 CALCULATIONS FOR ENHANCED | | | FASTENING FOR THE PERIMETER AND CORNER AREAS OF THE | | | ROOF. FBC - R301.2.1 | | | | | | 2) (NEW COMMENT) THE RAS 117 CALCULATIONS THAT WERE | | | SUBMITTED ARE BASED ON NOA NO.13-1022.15 WHICH HAS BEEN | | | SUPERCEDED BY NOA NO. 14-1030.01. THE SYSTEM AND | | | FASTENING OPTION THAT YOU INDICATED ON THE PRODUCT | | | APPROVAL THAT WAS SUBMITTED DOES NOT MATCH THE | | | CALCULATIONS. PLEASE SUBMIT MATCHING DOCUMENTS. FBC | | | 107.2.1 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-07-21 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-07-21 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2017-07-21 18:03:58 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE | | | BUILT UP ROOF (NOA NO.:14-1030.01) WILL REQUIRE | | | ENHANCED FASTENING IN ORDER TO MEET THE UPLIFT | | | PRESSURES FOR ROOF ZONES 2 AND 3. THE FASTENING OPTION | | | THAT YOU INDICATED ON PAGE 15 OF THE NOA HAS A MAXIMUM | | | DESIGN PRESSURE OF -52.5 PSF. THE REQUIRED UPLIFT | | | PRESSURES FOR ZONE 2 IS -63.6 PSF AND FOR ZONE 3 IS | | | -95.7 PER SHEET S.3 OF THE APPROVED PLANS. SEE | | | LIMITATION NUMBER 7 ON PAGE 31 AND SUBMIT TWO SETS OF | | | SIGNED AND SEALED RAS 117 CALCULATIONS FOR ENHANCED | | | FASTENING FOR THE PERIMETER AND CORNER AREAS OF THE | | | ROOF. FBC - R301.2.1 | | | | | | NOTE: THE LEDGER FASTENING DETAIL ON THE ROOF FRAMING | | | PLAN IS APPROVED. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-10-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-10-25 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-10-17 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2017-10-18 14:44:26 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-09-26 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-09-15 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2017-09-18 10:37:39 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-08-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-08-22 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-08-18 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2017-08-22 10:40:59 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-07-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-07-21 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-07-20 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2017-07-21 11:33:14 | SUBMITTAL ROUTED TO RMCDOUGAL |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |