Plan Review Details - Permit 17070703
Plan Review Stops For Permit 17070703
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-08-30 Cont ID  
Sent By shill Date 2017-08-30 Time 09:59 Rev Time 0.00
Received By shill Date 2017-08-30 Time 09:59 Sent To  
Notes
2017-08-30 10:01:58****PROVISO****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 18" MANEUVERING CLEARANCE REQUIRED FOR DOOR 2A, FBC A
 FIGURE 404.2.4.1(A)
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-08-02 Cont ID  
Sent By shill Date 2017-08-02 Time 11:03 Rev Time 0.00
Received By shill Date 2017-08-02 Time 11:03 Sent To  
Notes
2017-08-02 11:06:56****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. FBC EC C101.5, SEE THE CHECK LIST ON THE ENERGY
 CALCS; INPUT REPORT WAS NOT PROVIDED. PROVIDE THE INPUT
 REPORT, RE-RUN THE ENERGY CALCS.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-08-31 Cont ID  
Sent By jpearson Date 2017-08-31 Time 08:23 Rev Time 0.00
Received By jpearson Date 2017-08-31 Time 08:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-07-25 Cont ID  
Sent By jpearson Date 2017-07-25 Time 14:48 Rev Time 0.00
Received By jpearson Date 2017-07-25 Time 14:48 Sent To  
Notes
2017-07-25 14:58:01CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO INTERIOR
 PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM
 BONDING TERMINATION POINT. NEC 215.5, 230, 250.50,
 250.94, 408.30
 2. PROVIDE NOTE THAT THE SERVICE EQUIPMENT SHALL BE
 MARKED WITH THE MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT
 AVAILABLE PER NEC 110.24.
 3. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS FROM MAIN SERVICE (FOR ENTIRE BUILDING) FEEDING
 THIS UNIT TO CONFIRM THE CURRENT SERVICE SIZE IS
 ADEQUATE. NEC 220, 215.5, 215.2; FBC 107.2.1
 4. PROVIDE GRAPH OF INTERIOR LIGHTING POWER ALLOWANCES
 PER THE FBC ENERGY CODE IN RELATION TO THE CONNECTED
 INTERIOR LIGHTING PROPOSED TO COMPLY WITH CODE. FBC
 C405.5
 5. ALL RECEPTACLES IN KITCHEN/WORK AREA AND WITHIN 6
 FEET OF A SINK MUST BE GFCI PROTECTED. PROVIDE
 CORRECTION. NEC 210.8(B)(2),(5)
 6. PROVIDE CALCULATION FOR AVAILABLE SHORT CIRCUIT
 CURRENT AT NEW PANEL TO CONFIRM AIC RATING IS ADEQUATE.
 NEC 110.10
 7. PROVIDE AUTOMATIC CONTROL FOR SIGN AND SHOW WINDOW
 OUTLETS PER FBC ENERGY CODE. FBC C405.2.4
 8. PROVIDE AUTOMATIC LIGHTING CONTROL FOR LIGHTS OVER
 COUNTER ON CIRCUIT C36. FBC C405.2.2
  
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-08-30 Cont ID  
Sent By pleduc Date 2017-08-30 Time   Rev Time 0.00
Received By pleduc Date 2017-08-30 Time 13:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-07-25 Cont ID  
Sent By pleduc Date 2017-07-25 Time   Rev Time 0.00
Received By pleduc Date 2017-07-24 Time 16:45 Sent To  
Notes
2017-07-25 11:20:59THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1) SHEET A 3 - THE IS AN INCORRECT REFERENCE TO THE
 CURRENT EDITION OF THE FLORIDA FIRE PREVENTION CODE.
  
 THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE
 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING
 THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER
 APPLICABLE CODES OR STANDARDS.
  
  
 PLEASE CORRECT.
  
  
  
  
 2) SHEET A 3 - THERE IS AN INDICATION OF A HYBRID
 MICROWAVE OVEN. PLEASE CLARIFY THIS PIECE OF EQUIPMENT
 AND PROVIDE MANUFACTURERES SPEC.
  
 ADDITIONALLY, PLEASE PROVIDE A REVIEW OF THE PROPOSED
 TYPE OF FOOD PRODUCTS OR MENU. COMMERCIAL COOKING WITH
 GREASE LADEN VAPORS SHALL COMPLY WITH NFPA 96.
  
 PLEASE PROVIDE DETAILS.
  
  
  
 3) SHEET A 3 - THERE IS INDICATIONS OF EXISTING FIRE
 SPRINKLERS. ANY REMODEL WORK REQUIRES AN EVALUATION OF
 THE SPRINKLER SYSTEM FOR CODE COMPLIANT COVERAGE.
  
 ANY WORK ON THE SPRINKLER SYSTEM SHALL BE DONE UNDER
 SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY
 CONTRACTORS.
  
 PLEASE PROVIDE A NOTE OF COMPLIANCE.
  
  
  
  
 4) SHEET A 3 - THE IS A DOOR INDICATED, 2 A, FROM THE
 WORK AREA LEADING TO THE REAR DOOR. THIS IS A DOOR IN
 THE MEANS OF EGRESS ACCORDING TO THE LIFE SAFETY PLAN.
  
 THE DOOR SCHEDULE DOES NOT INDICATE ANY HARDWARE, LOCKS
 OR LATCHES FOR THIS DOOR. THE HARDWARE, LOCKS AND
 LATCHES SHALL COMPLY WITH NFPA 101, CHAPTER 7, MEANS OF
 EGRESS.
  
 PLEASE PROVIDE DETAILS AS APPLICABLE THAT MEET THE
 REQUIREMENTS.
  
  
  
  
 5) SHEET E 1 - THERE ARE NO INDICATIONS OF FIRE ALARM
 EQUIPMENT/DEVICES. ANY REMODEL WORK REQUIRES AN
 EVALUATION OF ANY EXISIING FIRE ALARM SYSTEM DEVICES.
  
 ANY WORK ON THE ALARM SYSTEM SHALL BE DONE UNDER
 SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY
 CONTRACTORS.
  
 PLEASE PROVIDE A NOTE OF COMPLIANCE.
  
  
  
  
 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
  
 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2017-09-27 Time   Rev Time 0.00
Received By lmarchan Date 2017-09-22 Time 14:58 Sent To  
Notes
2017-09-25 14:58:29RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-09-13 Cont ID  
Sent By njwira Date 2017-09-13 Time 09:52 Rev Time 0.00
Received By njwira Date 2017-08-28 Time 14:49 Sent To  
Notes
2017-08-29 14:50:12B19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-08-04 Cont ID  
Sent By njwira Date 2017-08-04 Time 17:12 Rev Time 0.00
Received By njwira Date 2017-07-18 Time 12:56 Sent To  
Notes
2017-07-19 12:56:49B04

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2017-10-06 Cont ID  
Sent By shill Date 2017-10-06 Time 14:18 Rev Time 0.00
Received By shill Date 2017-10-06 Time 14:18 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-08-02 Cont ID  
Sent By shill Date 2017-08-02 Time 11:28 Rev Time 0.00
Received By shill Date 2017-08-02 Time 11:15 Sent To  
Notes
2017-08-02 11:15:26IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED
 CONTACT 561-233-5025 FOR MORE INFORMATION
 THE STAMPED PLAN AND THE RECEIPT SHOWING FEES DUE WERE
 PAID, IF APPLICABLE, ARE TO BE PROVIDED
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-09-27 Cont ID  
Sent By ccole Date 2017-09-27 Time 16:45 Rev Time 0.00
Received By ccole Date 2017-09-27 Time 16:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-09-06 Cont ID  
Sent By ccole Date 2017-09-06 Time 12:26 Rev Time 0.00
Received By ccole Date 2017-09-06 Time 12:25 Sent To  
Notes
2017-09-06 12:26:462ND REVIEW FBC-2014 MECHANICAL
 PERMIT #17070703
 9/6/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M1: THE REQUIRED MAKEUP AIR FOR THE OVEN
 EXHAUST CANNOT REDUCE THE REQUIRED RATE OF OUTDOOR
 AIRFLOW TO THE BREATHING ZONE IN THE OCCUPIED SPACES OF
 THE COFFEE SHOP- SECTION 403.3. PLEASE PROVIDE MAKEUP
 AIR AT A RATE APROXIMATELY EQUAL TO THE AMOUNT OF
 EXHAUST AIR REQUIRED- SECTION 508.1.
  
 2) SHOW HOW THE EXHAUST FAN WILL BE OPERATE
 AUTOMATICALLY WHEN THE OVEN IS IN USE- SECTION 507.1.
  
 3) THE SUBMITTED SPECS FOR THE BROAN EXHAUST FAN APPEAR
 TO INDICATE THE FAN IS FOR RESIDENTIAL USE, AND HAS NOT
 BEEN APPROVED TO EXHAUST A COMMERCIAL COOKING OVEN-
 506.5.
  
 4) VERIFY THAT THE OVEN EXHAUST WILL TERMINATE NO LESS
 THAN 30" ABOVE THE ADJOINING ROOF- SECTION 506.4.2.
  
 5) THE SUBMITTED SPECS FOR THE OVEN DO NOT INDICATE THE
 APPLIANCE IS LISTED AND LABELED IN ACCORDANCE WITH
 UL-197. SEE SECTION 917.1.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-07-24 Cont ID  
Sent By ccole Date 2017-07-24 Time 14:33 Rev Time 0.00
Received By ccole Date 2017-07-24 Time 14:27 Sent To  
Notes
2017-07-24 14:46:481ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17070703
 7/24/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE NEW OVEN SHALL EITHER BE PROVIDED WITH A TYPE II
 EXHAUST HOOD OR THE SPACE SHALL BE PROVIDED WITH
 EXHAUST VENTILATION AT A RATE OF 0.70 CFMS PER SQ. FT.-
 SECTION 507.2.2.
  
 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE NEW
 OVEN- SECTION 917.1.
  
 3) PROVIDE AN AIR BALANCE CALCULATION.
  
 4) PLEASE NOTE THAT SEPARATE PERMITS ARE REQUIRED FOR
 KITCHEN EXHAUST HOODS AND FIRE SUPPRESSION SYSTEMS-
 SECTION 107.1 WPB AMENDMENTS TO THE FBC.
  
 5) THE REQUIRED INPUT DATA REPORT WAS NOT SUBMITTED
 ALONG WITH ENERGYGAUGE COMPLIANCE REPORT.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-09-07 Cont ID  
Sent By thunt Date 2017-09-07 Time 15:44 Rev Time 0.00
Received By thunt Date 2017-09-07 Time 14:52 Sent To Z
Notes
2017-09-07 15:44:43SEPERATE PERMIT REQUIRED FOR THE GREASE INTERCEPTOR

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-07-24 Cont ID  
Sent By gjohnson Date 2017-07-24 Time 07:53 Rev Time 0.00
Received By gjohnson Date 2017-07-21 Time 11:32 Sent To Z
Notes
2017-07-24 09:45:201ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT. A-2 WITH AN OCCUPANT LOAD OF 28 PEOPLE SEPARATE
 FACILITIES SHALL BE PROVIDED FOR EACH SEX. PER FBC PL
 403.2
  
 2.THE AAV FOR THE GREASE INTERCEPTOR SHALL BE INSTALLED
 ABOVE FLOOD LEVEL RIM OF THE HIGHEST FIXTURE SERVED.
 PER FBC PL 918.4
  
 3. THE SAMPLE PORT SHALL NOT HAVE A SUMP ON THE BOTTOM
 A 4" TWO WAY CLEAN OUT IS ALL THAT IS REQUIRED.
  
 4. THE INLET OF THE GB 75 IS 4" THE DRAIN THAT IS
 CONNECTED TO THE OUTLET SHALL BE 4" THE SIZE OF THE
 DRAINAGE PIPING SHALL NOT BE REDUCED IN SIZE IN THE
 DIRECTION OF THE FLOW. PER FBC PL 704.2
  
 5. WHAT TYPE OF COOKING WILL BE DONE AT THIS LOCATION,
 PLEASE PROVIDE A MENU TO DETERMINE WHAT TYPE IF ANY
 TYPE OF GREASY WASTE WILL BE PRODUCED. I NO GREASY
 WASTE IS PRODUCED A GREASE INTERCEPTOR IS NOT REQUIRED.
 PER FBC PL 1003.3.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2017-09-13 Cont ID  
Sent By njwira Date 2017-09-13 Time 09:52 Rev Time 0.00
Received By njwira Date 2017-08-31 Time 15:43 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-08-04 Cont ID  
Sent By njwira Date 2017-08-04 Time 17:12 Rev Time 0.00
Received By njwira Date 2017-08-04 Time 16:37 Sent To I
Notes
***NONE***