| Plan Review Stops For Permit 17070703 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-30 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-30 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2017-08-30 10:01:58 | ****PROVISO**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 18" MANEUVERING CLEARANCE REQUIRED FOR DOOR 2A, FBC A | | | FIGURE 404.2.4.1(A) | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-02 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-02 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2017-08-02 11:06:56 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FBC EC C101.5, SEE THE CHECK LIST ON THE ENERGY | | | CALCS; INPUT REPORT WAS NOT PROVIDED. PROVIDE THE INPUT | | | REPORT, RE-RUN THE ENERGY CALCS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-08-31 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-31 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-31 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-07-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-25 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-25 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2017-07-25 14:58:01 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO INTERIOR | | | PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM | | | BONDING TERMINATION POINT. NEC 215.5, 230, 250.50, | | | 250.94, 408.30 | | | 2. PROVIDE NOTE THAT THE SERVICE EQUIPMENT SHALL BE | | | MARKED WITH THE MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT | | | AVAILABLE PER NEC 110.24. | | | 3. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS FROM MAIN SERVICE (FOR ENTIRE BUILDING) FEEDING | | | THIS UNIT TO CONFIRM THE CURRENT SERVICE SIZE IS | | | ADEQUATE. NEC 220, 215.5, 215.2; FBC 107.2.1 | | | 4. PROVIDE GRAPH OF INTERIOR LIGHTING POWER ALLOWANCES | | | PER THE FBC ENERGY CODE IN RELATION TO THE CONNECTED | | | INTERIOR LIGHTING PROPOSED TO COMPLY WITH CODE. FBC | | | C405.5 | | | 5. ALL RECEPTACLES IN KITCHEN/WORK AREA AND WITHIN 6 | | | FEET OF A SINK MUST BE GFCI PROTECTED. PROVIDE | | | CORRECTION. NEC 210.8(B)(2),(5) | | | 6. PROVIDE CALCULATION FOR AVAILABLE SHORT CIRCUIT | | | CURRENT AT NEW PANEL TO CONFIRM AIC RATING IS ADEQUATE. | | | NEC 110.10 | | | 7. PROVIDE AUTOMATIC CONTROL FOR SIGN AND SHOW WINDOW | | | OUTLETS PER FBC ENERGY CODE. FBC C405.2.4 | | | 8. PROVIDE AUTOMATIC LIGHTING CONTROL FOR LIGHTS OVER | | | COUNTER ON CIRCUIT C36. FBC C405.2.2 | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-08-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-08-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-08-30 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-07-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-07-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-07-24 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2017-07-25 11:20:59 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) SHEET A 3 - THE IS AN INCORRECT REFERENCE TO THE | | | CURRENT EDITION OF THE FLORIDA FIRE PREVENTION CODE. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | | | | PLEASE CORRECT. | | | | | | | | | | | | | | | 2) SHEET A 3 - THERE IS AN INDICATION OF A HYBRID | | | MICROWAVE OVEN. PLEASE CLARIFY THIS PIECE OF EQUIPMENT | | | AND PROVIDE MANUFACTURERES SPEC. | | | | | | ADDITIONALLY, PLEASE PROVIDE A REVIEW OF THE PROPOSED | | | TYPE OF FOOD PRODUCTS OR MENU. COMMERCIAL COOKING WITH | | | GREASE LADEN VAPORS SHALL COMPLY WITH NFPA 96. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | | | | 3) SHEET A 3 - THERE IS INDICATIONS OF EXISTING FIRE | | | SPRINKLERS. ANY REMODEL WORK REQUIRES AN EVALUATION OF | | | THE SPRINKLER SYSTEM FOR CODE COMPLIANT COVERAGE. | | | | | | ANY WORK ON THE SPRINKLER SYSTEM SHALL BE DONE UNDER | | | SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY | | | CONTRACTORS. | | | | | | PLEASE PROVIDE A NOTE OF COMPLIANCE. | | | | | | | | | | | | | | | 4) SHEET A 3 - THE IS A DOOR INDICATED, 2 A, FROM THE | | | WORK AREA LEADING TO THE REAR DOOR. THIS IS A DOOR IN | | | THE MEANS OF EGRESS ACCORDING TO THE LIFE SAFETY PLAN. | | | | | | THE DOOR SCHEDULE DOES NOT INDICATE ANY HARDWARE, LOCKS | | | OR LATCHES FOR THIS DOOR. THE HARDWARE, LOCKS AND | | | LATCHES SHALL COMPLY WITH NFPA 101, CHAPTER 7, MEANS OF | | | EGRESS. | | | | | | PLEASE PROVIDE DETAILS AS APPLICABLE THAT MEET THE | | | REQUIREMENTS. | | | | | | | | | | | | | | | 5) SHEET E 1 - THERE ARE NO INDICATIONS OF FIRE ALARM | | | EQUIPMENT/DEVICES. ANY REMODEL WORK REQUIRES AN | | | EVALUATION OF ANY EXISIING FIRE ALARM SYSTEM DEVICES. | | | | | | ANY WORK ON THE ALARM SYSTEM SHALL BE DONE UNDER | | | SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY | | | CONTRACTORS. | | | | | | PLEASE PROVIDE A NOTE OF COMPLIANCE. | | | | | | | | | | | | | | | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-09-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-09-22 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2017-09-25 14:58:29 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-09-13 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-08-28 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-08-04 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-08-04 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-07-18 |
Time |
12:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2017-10-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-10-06 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-10-06 |
Time |
14:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-02 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-02 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2017-08-02 11:15:26 | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED | | | CONTACT 561-233-5025 FOR MORE INFORMATION | | | THE STAMPED PLAN AND THE RECEIPT SHOWING FEES DUE WERE | | | PAID, IF APPLICABLE, ARE TO BE PROVIDED | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-09-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-09-27 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-09-27 |
Time |
16:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-09-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-09-06 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-09-06 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2017-09-06 12:26:46 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17070703 | | | 9/6/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M1: THE REQUIRED MAKEUP AIR FOR THE OVEN | | | EXHAUST CANNOT REDUCE THE REQUIRED RATE OF OUTDOOR | | | AIRFLOW TO THE BREATHING ZONE IN THE OCCUPIED SPACES OF | | | THE COFFEE SHOP- SECTION 403.3. PLEASE PROVIDE MAKEUP | | | AIR AT A RATE APROXIMATELY EQUAL TO THE AMOUNT OF | | | EXHAUST AIR REQUIRED- SECTION 508.1. | | | | | | 2) SHOW HOW THE EXHAUST FAN WILL BE OPERATE | | | AUTOMATICALLY WHEN THE OVEN IS IN USE- SECTION 507.1. | | | | | | 3) THE SUBMITTED SPECS FOR THE BROAN EXHAUST FAN APPEAR | | | TO INDICATE THE FAN IS FOR RESIDENTIAL USE, AND HAS NOT | | | BEEN APPROVED TO EXHAUST A COMMERCIAL COOKING OVEN- | | | 506.5. | | | | | | 4) VERIFY THAT THE OVEN EXHAUST WILL TERMINATE NO LESS | | | THAN 30" ABOVE THE ADJOINING ROOF- SECTION 506.4.2. | | | | | | 5) THE SUBMITTED SPECS FOR THE OVEN DO NOT INDICATE THE | | | APPLIANCE IS LISTED AND LABELED IN ACCORDANCE WITH | | | UL-197. SEE SECTION 917.1. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-24 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-24 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2017-07-24 14:46:48 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17070703 | | | 7/24/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE NEW OVEN SHALL EITHER BE PROVIDED WITH A TYPE II | | | EXHAUST HOOD OR THE SPACE SHALL BE PROVIDED WITH | | | EXHAUST VENTILATION AT A RATE OF 0.70 CFMS PER SQ. FT.- | | | SECTION 507.2.2. | | | | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE NEW | | | OVEN- SECTION 917.1. | | | | | | 3) PROVIDE AN AIR BALANCE CALCULATION. | | | | | | 4) PLEASE NOTE THAT SEPARATE PERMITS ARE REQUIRED FOR | | | KITCHEN EXHAUST HOODS AND FIRE SUPPRESSION SYSTEMS- | | | SECTION 107.1 WPB AMENDMENTS TO THE FBC. | | | | | | 5) THE REQUIRED INPUT DATA REPORT WAS NOT SUBMITTED | | | ALONG WITH ENERGYGAUGE COMPLIANCE REPORT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-09-07 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-09-07 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-09-07 |
Time |
14:52 |
Sent To |
Z |
|
| Notes |
| 2017-09-07 15:44:43 | SEPERATE PERMIT REQUIRED FOR THE GREASE INTERCEPTOR |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-07-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-24 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-21 |
Time |
11:32 |
Sent To |
Z |
|
| Notes |
| 2017-07-24 09:45:20 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. A-2 WITH AN OCCUPANT LOAD OF 28 PEOPLE SEPARATE | | | FACILITIES SHALL BE PROVIDED FOR EACH SEX. PER FBC PL | | | 403.2 | | | | | | 2.THE AAV FOR THE GREASE INTERCEPTOR SHALL BE INSTALLED | | | ABOVE FLOOD LEVEL RIM OF THE HIGHEST FIXTURE SERVED. | | | PER FBC PL 918.4 | | | | | | 3. THE SAMPLE PORT SHALL NOT HAVE A SUMP ON THE BOTTOM | | | A 4" TWO WAY CLEAN OUT IS ALL THAT IS REQUIRED. | | | | | | 4. THE INLET OF THE GB 75 IS 4" THE DRAIN THAT IS | | | CONNECTED TO THE OUTLET SHALL BE 4" THE SIZE OF THE | | | DRAINAGE PIPING SHALL NOT BE REDUCED IN SIZE IN THE | | | DIRECTION OF THE FLOW. PER FBC PL 704.2 | | | | | | 5. WHAT TYPE OF COOKING WILL BE DONE AT THIS LOCATION, | | | PLEASE PROVIDE A MENU TO DETERMINE WHAT TYPE IF ANY | | | TYPE OF GREASY WASTE WILL BE PRODUCED. I NO GREASY | | | WASTE IS PRODUCED A GREASE INTERCEPTOR IS NOT REQUIRED. | | | PER FBC PL 1003.3.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-09-13 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-08-31 |
Time |
15:43 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-08-04 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-08-04 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-08-04 |
Time |
16:37 |
Sent To |
I |
|
| Notes |
|
|