| Plan Review Stops For Permit 17070620 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-08-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-08-15 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-08-15 |
Time |
06:00 |
Sent To |
|
|
| Notes |
| 2017-08-15 07:10:00 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17070620 | | | ADD: 8170 OKEECHOBEE BLVD. SUITE: 7 | | | CONT: ATLANTIC ENGINEERING SERVICES | | | TEL: 561-358-4140 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: TUES. AUGUST 15/ 2017 | | | ACTION: BUILDING PROVISO | | | | | | 1) BEFORE FRAMING INSPECTION COMPLY WITH, SHEET A-1 | | | DOOR NOTE # 1 INDICATES A NEW EXTERIOR DOOR, 3 FT. X 8 | | | FT. ALUM. & GLASS STOREFRONT TRULITE GLASS & ALUMINUM | | | SOLUTIONS. | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS | | | | | | 2) IDENTIFY GLAZING. PLEASE IDENTIFY ON THE PRODUCT | | | APPROVAL BEFORE SUBMITTING TO DESIGNER OF RECORD AND | | | BEFORE SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL | | | PRODUCTS WITH GLAZING, PLEASE IDENTIFY THE OPENING | | | WIDTH & HEIGHT, TYPE OF GLAZING, MULLION INFORMATION IF | | | REQUIRED, ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH | | | OPENING SIZE. 2014 FBC-B 1405.13.1 INSTALLATION. | | | WINDOWS AND DOORS SHALL BE INSTALLED IN ACCORDANCE WITH | | | APPROVED MANUFACTURER?S INSTRUCTIONS. FASTENER SIZE AND | | | SPACING SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND | | | SHALL BE CALCULATED BASED ON MAXIMUM LOADS AND SPACING | | | USED IN THE TESTS. | | | | | | 3) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-07-20 |
Time |
09:28 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2017-07-20 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2017-07-20 09:28:41 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17070620 | | | ADD: 8170 OKEECHOBEE BLVD. SUITE: 7 | | | CONT: ATLANTIC ENGINEERING SERVICES | | | TEL: 561-358-4140 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. JULY 20/ 2017 | | | ACTION: DENIED | | | | | | 1) SHEET A-2 IT APPEARS THERE MAY BE A DISCREPANCY IN | | | THE PLANS. THE 2 ELEVATION VIEWS OF THE RESTROOM THE | | | NORTH AND EAST SHOW TILE ON THE WALLS BUT WHEN YOU GO | | | TO THE ROOM FINISH SCHEDULE, SAME PAGE IT APPEARS THE | | | WALLS ARE A PAINT FINISH WITH NOTE (4). PLEASE PROVIDE | | | COMPLIANCE WITH THE 2014 FBC-B 1210.2.2 WALLS AND | | | PARTITIONS. WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) | | | OF SERVICE SINKS, URINALS AND WATER CLOSETS SHALL HAVE | | | A SMOOTH, HARD, NONABSORBENT SURFACE, TO A HEIGHT OF | | | NOT LESS THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND | | | EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN | | | SUCH WALLS SHALL BE OF A TYPE THAT IS NOT ADVERSELY | | | AFFECTED BY MOISTURE. | | | | | | 2) THE MECHANICAL SHEET M-1 NOTE #9 IS FOR THROUGH THE | | | WALL LOUVERS FOR EITHER INTAKE OR EXHAUST AIR. | | | SHEET M-3 DETAIL 8 IDENTIFIES THE WALL LOUVER AS A | | | MIAMI-DADE NOA 12-0830.08. PLEASE PROVIDE FOR | | | COMPLIANCE WITH 1609.6.4.4.1 COMPONENTS & CLADDING. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE | | | CODE 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31(C) WALL LOUVERS | | | | | | 3) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-09 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-09 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-07-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-24 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-24 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2017-07-24 10:43:22 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS: | | | | | | 1. SPECS FOR EEMAX SP2412DL RECOMMEND A WIRE SIZE OF | | | #10. PROVIDE CORRECTION. NEC 110.3 | | | 2. POWER PLAN SHOWS THE SAME CIRCUIT FOR EWH AND ERV. | | | PROVIDE CORRECTION. FBC 107.2.1, NEC 408.4 | | | 3. PLEASE PROVIDE A BLOCK NOTE INDICATING THE REQUIRED | | | SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR ALL LOW VOLTAGE SYSTEMS TO INCLUDE BUT | | | NOT LIMITED TO FIRE ALARM, CCTV, PHONE AND DATA, | | | WIRELESS SYSTEMS, KITCHEN HOODS ETC. A NOTE WILL | | | SUFFICE. FBC 105.1 | | | 4. NOTE 20 ON E-1 STATES THERE IS NO FIRE ALARM, BUT | | | NOTES 5 AND 11 ON MECHANICAL DRAWING REFERENCE FIRE | | | ALARM WORK. PROVIDE CORRECTION. FBC 107.2.1 | | | 5. PROVIDE SHORT CIRCUIT CALCULATION FOR SERVICE | | | FEEDERS AND RATING OF ELECTRICAL PANEL TO CONFIRM | | | ADEQUATE RATING. NEC 110.9, 110.10 | | | 6. PROVIDE AUTOMATIC CONTROL OF SHOW WINDOW OUTLETS. | | | FBC C405.2.2.1, C405.2.3 | | | 7. ELECTRICAL RISER DIAGRAM APPEARS TO SHOW A JUNCTION | | | BOX BELOW SLAB. JUNCTION BOXES ARE REQUIRED TO BE | | | ACCESSIBLE. PROVIDE CORRECTION. NEC 314.29 | | | 8. SPECS FOR ERV STATE THAT THE MOCP SHOULD BE 15 AMP. | | | PANEL SCHEDULE SHOWS A 20 AMP BREAKER TO THIS UNIT. | | | PROVIDE CORRECTION. NEC 110.3, FBC 107.2.1 | | | 9. CIRCUIT 32 AND 34 SHOW A #14 WIRE ON A 20 AMP | | | BREAKER. PROVIDE CORRECTION. NEC 310.15(B)(16), 240.4 | | | 10. NOTE 12 ON E-1 STATES MINIMUM WIRE SIZE SHALL BE | | | #12, BUT SEVERAL CIRCUITS ARE SHOWN WITH #14 WIRE. | | | CLARIFY AND/OR CORRECT. FBC 107.2.1 | | | 11. SEVERAL OUTLETS ON CIRCUIT 10 AND 12 APPEAR TO BE | | | WITHIN 6 FEET OF A SINK AND DO NOT SHOW GFCI | | | PROTECTION. PROVIDE GFCI PROTECTION REQUIRED PER CODE. | | | NEC 210.8 | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-08-16 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-08-16 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-07-21 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-07-21 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-07-21 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-08-17 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-08-17 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-08-07 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-07-26 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-07-26 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2017-07-17 |
Time |
15:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-07-20 |
Time |
09:28 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2017-07-20 |
Time |
07:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-08-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-14 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-14 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-24 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-24 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2017-07-24 14:01:31 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17070620 | | | 7/24/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE ERV EXHAUST OUTLET APPEARS TO BE WITHIN THE | | | REQUIRED 10' CLEARANCE DISTANCE TO THE REAR DOOR- | | | SECTION 501.3.1(2). | | | | | | 2) SHOW THE ERV CONDENSATE PIPING RUN AND DISCHARGE | | | LOCATION. | | | | | | 3) SUBMIT A FL. PRODUCT APPROVAL OR MIAMI-DADE NOA GOT | | | THE LOUVERS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
P |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-07-20 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-07-20 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2017-07-20 09:59:39 | FBC BUILDING 1612 AND CITY OF WPB CODE OF ORDINANCES | | | SECTION 94-546. STRUCTURE IS LOCATED IN AN "A" FLOOD | | | ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED. | | | PLEASE REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS | | | REQUIRE AN ADDITIONAL 6 INCHES/ (12 INCHES OF ELEVATION | | | IF PERMIT APPLICATION IS ON OR AFTER SEPT. 12/2016. | | | | | | THIS IS A SHELL BUILDING: | | | DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE | | | REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES | | | REQUIRED: | | | | | | (1) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY | | | OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE | | | CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR | | | ATTENDANTS A/C PADS OR OTHER SLABS FOR GENERATORS. | | | W. P. B. ADMINISTRATIVE CODE 110.3 REQUIRED INSPECTIONS | | | (6) FINAL INSPECTION. TO BE MADE AFTER THE BUILDING IS | | | COMPLETED AND READY FOR OCCUPANCY. 6.1. LOWEST FLOOR | | | ELEVATION. IN FLOOD HAZARD AREAS, AS PART OF THE FINAL | | | INSPECTION, A FINAL CERTIFICATION OF THE LOWEST FLOOR | | | ELEVATION SHALL BE SUBMITTED TO THE AUTHORITY HAVING | | | JURISDICTION. | | | | | | FEMA NEW FORM AVAILABLE JUNE 13/2016. | | | OMB NO. 1660-0008 | | | EXPIRATION DATE: NOV. 30/2018 | | | HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM | | | | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-08-17 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-08-17 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-08-17 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2017-08-17 16:20:53 | IF DEVELOPED LENGHT FROM ANY HOT OR TEMPERED WATER | | | PIPING EXCEEDS 50" THEN A RECIRCULATION SYSTEM SHALL BE | | | REQUIRED. MUST ALSO THEN COMPLY WITH 607.3 AND 607.5 | | | FPC. | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6696 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-20 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-20 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2017-07-20 17:39:51 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE WASHING MACHINE FIXTURE BRANCH DRAIN SHALL BE | | | 3". PER FBC PL 406.2 | | | | | | 2. A LENT TRAP IS REQUIRED FOR WASHING MACHINE. PER FBC | | | PL 1003.6 | | | | | | 3. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 | | | | | | 4. THE SINK AT THE HOSTESS STATION SHALL COMPLY WITH | | | FBC ACC 606.2 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR | | | A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE | | | COMPLYING WITH 306 SHALL BE PROVIDED | | | 606.3 HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES | | | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-08-15 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-08-15 |
Time |
10:24 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2017-08-15 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-07-26 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-07-26 |
Time |
09:47 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2017-07-26 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2017-07-26 10:04:25 | FAILED | | | | | | PROVIDE A WRITTEN RESPONSE. | | | | | | 1) THE PLANS LIST THIS AS BUILD-OUT FOR SUITE #7. THE | | | PLANS SHOW AN EXISTING DOOR ON THE NORTH SIDE OF THE | | | SUITE. THE PLANS REVIEWED BY ZONING TO DATE FOR THIS | | | BUILDING SHOW THIS AS BEING A WINDOW NOT A DOOR. PLEASE | | | EXPLAIN. NOTE: ZONING STAFF DOES NOT OBJECT TO THIS | | | BEING A DOOR AS OPPOSED TO A WINDOW PROVIDED IT IS A | | | GLAZED DOOR, BUT THE PLANS NEED TO SHOW THE CHANGE FROM | | | THE WINDOW TO THE DOOR, WITH DOOR SPECIFICATIONS. | | | | | | 2) EXCEPT FOR THE CLARIFICATION REQUIRED BY COMMENT NO. | | | 1, THE PLANS COMPLY WITH ZONING REQUIREMENTS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|