Plan Review Details - Permit 17070579
| Plan Review Stops For Permit 17070579 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-08-09 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-09 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2017-08-09 07:50:19 | ****PROVISOS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | COMMENTS FROM PREVIOUS LIST, NOT ADDRESS, NOW PROVISO | | | ITEMS: | | | | | | 1. ALTHOUGH NOT CLOUDED AS A CHANGE ON A2 AND RELATED | | | BUILDING SHEETS, IT APPEARS THAT AN ADDITIONAL ACU WAS | | | ADDED, AND THE LOCATION OF THE OTHER ACU CHANGED. THE | | | PLAN SHOWS AN ALLEY ON THAT SIDE OF THE BUILDING, BUT | | | WITH NO DIMENSIONS. | | | | | | CLOUD ALL CHANGES, AND REVISE PLAN TO SHOW WIDTH OF | | | "ALLEY". REVISE PLAN TO SHOW DIMENSIONS OF ACUS. REVISE | | | PLAN TO EITHER SHOW ALL DOORS ON THE ADJACENT BUILDING, | | | OR REVISE PLAN TO NOTE THAT THERE ARE NO DOORS ON THE | | | WALL OF THE ADJACENT BUILDING, FBC 107, FBC CHAPTER 10. | | | | | | ***OR*** | | | | | | IF THIS PAGE DOES NOT NEED TO BE CHANGED FOR ANY OTHER | | | REASON, THIS ITEM MAY BE ADDRESSED WITH A SIGNED AND | | | SEALED LETTER. STATE THAT THIS IS THE ONLY CHANGE, THAT | | | THERE ARE NO DOORS ON ADJACENT BUILDING, AND THAT | | | EXITING FOR ADJACENT BUILDING IS NOT AFFECTED. | | | | | | PROVISO, RESPONSE LETTER STATES THAT A NOTE WAS ADDED. | | | UNABLE TO LOCATE. PROVISO, NO DOORS ARE EXISTING ON THE | | | ADJACENT BUILDING. | | | | | | 2. PROVIDE A VALUE FOR THE ADDITIONAL WORK, FBC 109. | | | ADDITIONAL MECHANICAL WORK, ENTRY DOOR ARE INCLUDED IN | | | THIS REVISION. | | | | | | RESPONSE LETTER STATES THERE IS NO ADDITIONAL VALUE, | | | THIS IS AN "AS BUILT". $5000 ADDED FOR VALUE AS PLAN | | | SHOWS ADDITIONAL WORK. | | | | | | 3. PROVIDE A PRODUCT APPROVAL FOR THE PROPOSED NEW | | | DOOR, FBC 1609. | | | | | | THE PRODUCT APPROVAL PROVIDED IS FOR AN INSWING OPAQUE | | | DOOR; THE DOOR ON THE PLAN IS OUTSWING GLAZED. | | | | | | 4. SHEET A4 WAS SUBMITTED, UNABLE TO LOCATE A CHANGE TO | | | THE PLAN, FBC 107. CLOUD AND NUMBER OR DIRECT AS TO | | | WHERE THE CHANGE(S) IS(ARE). | | | | | | RESPONSE LETTER STATES NOTHING HAS CHANGED. PROVISO, | | | THIS SHEET HAS NOT BEEN REVIEWED AND HAS BEEN VOIDED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-25 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-25 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2017-07-25 08:49:42 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. ALTHOUGH NOT CLOUDED AS A CHANGE ON A2 AND RELATED | | | BUILDING SHEETS, IT APPEARS THAT AN ADDITIONAL ACU WAS | | | ADDED, AND THE LOCATION OF THE OTHER ACU CHANGED. THE | | | PLAN SHOWS AN ALLEY ON THAT SIDE OF THE BUILDING, BUT | | | WITH NO DIMENSIONS. | | | | | | CLOUD ALL CHANGES, AND REVISE PLAN TO SHOW WIDTH OF | | | "ALLEY". REVISE PLAN TO SHOW DIMENSIONS OF ACUS. REVISE | | | PLAN TO EITHER SHOW ALL DOORS ON THE ADJACENT BUILDING, | | | OR REVISE PLAN TO NOTE THAT THERE ARE NO DOORS ON THE | | | WALL OF THE ADJACENT BUILDING, FBC 107, FBC CHAPTER 10. | | | | | | ***OR*** | | | | | | IF THIS PAGE DOES NOT NEED TO BE CHANGED FOR ANY OTHER | | | REASON, THIS ITEM MAY BE ADDRESSED WITH A SIGNED AND | | | SEALED LETTER. STATE THAT THIS IS THE ONLY CHANGE, THAT | | | THERE ARE NO DOORS ON ADJACENT BUILDING, AND THAT | | | EXITING FOR ADJACENT BUILDING IS NOT AFFECTED. | | | | | | 2. PROVIDE A VALUE FOR THE ADDITIONAL WORK, FBC 109. | | | ADDITIONAL MECHANICAL WORK, ENTRY DOOR ARE INCLUDED IN | | | THIS REVISION. | | | | | | 3. PROVIDE A PRODUCT APPROVAL FOR THE PROPOSED NEW | | | DOOR, FBC 1609. | | | | | | 4. SHEET A4 WAS SUBMITTED, UNABLE TO LOCATE A CHANGE TO | | | THE PLAN, FBC 107. CLOUD AND NUMBER OR DIRECT AS TO | | | WHERE THE CHANGE(S) IS(ARE). | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-09 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-09 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2017-08-09 09:20:58 | APPROVED WITH EXCEPTION: | | | | | | PROVISO: DESIGN PROFESSIONAL SHALL PROVIDE CALCULATION | | | FOR REDUCTION IN NEUTRAL SIZE TO PANEL C PRIOR TO FINAL | | | INSPECTION. PROVIDE TO INSPECTOR AT TIME OF INSPECTION. | | | NEC 220.61 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-07-20 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-20 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2017-07-20 14:26:09 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS: | | | | | | 1. ELECTRICAL PLAN SHOWS 4 ELECTRIC COMPANY METERS, THE | | | RISER DIAGRAM SHOWS 2. PROVIDE ACCURATE RISER DIAGRAM | | | AND ELECTRICAL PLAN SHOWING THE LOCATION AND NAME OF | | | EACH SERVICE AND THE CORRESPONDING SERVICE EQUIPMENT, | | | AND THE RATING OF EACH DISCONNECT AND PANEL. NEC 215.5, | | | 408.30, FBC 107.2.1 | | | 2. RISER DIAGRAM FOR PANEL C SHOWS 3-3/0 CONDUCTORS IN | | | A 2 INCH CONDUIT FEEDING THE INTERIOR PANEL. AN | | | EQUIPMENT GROUNDING CONDUCTOR IS REQUIRED IN THIS | | | CONDUIT. PROVIDE CORRECTION. NEC 250.122, 250.24(A)(5) | | | 3. RISER DIAGRAM FOR PANEL A SHOWS 3/0 CONDUCTORS, | | | WHICH IS RATED FOR 200 AMPS. THE LOAD CALCULATION | | | PROVIDED FOR PANEL A AND PANEL B ADDED TOGETHER EQUALS | | | 206 AMPS, WHICH EXCEEDS THE RATING OF THE WIRE. THE | | | LOAD FOR PANEL B IS NOT INCLUDED IN THE PANEL SCHEDULE | | | FOR PANEL A, BUT IS SHOWN ON THE RISER AS BEING FED | | | FROM PANEL A. PROVIDE ACCURATE LOAD CALCULATION AND | | | CIRCUIT DIRECTORY FOR PANEL A, PROVIDE PROPERLY SIZED | | | FEEDERS. NEC 215.2, 215.5, 220, 408.4, 310.15(B)(16) | | | 4. IN ADDITION TO COMMENT #3, PANEL B IS SHOWN AS A | | | MAIN LUG ONLY PANEL. IF THIS IS ACCURATE, PROVIDE OVER | | | CURRENT PROTECTION DETAILS. NEC 215.2, 240.4, 408.30, | | | FBC 107.2.1 | | | 5. IF PANEL B IS FED FROM PANEL A, WHICH IS SHOWN AS A | | | 200 AMP PANEL, THEN THIS PANEL IS ALSO OVERLOADED. | | | PROVIDE CORRECTION. NEC 408.30 | | | 6. THE WIRE FEEDING PANEL B DOES NOT INCLUDE THE | | | REQUIRED EQUIPMENT GROUNDING CONDUCTOR. PROVIDE | | | CORRECTION. NEC 250.122, 250.24(A)(5) | | | 7. EMERGENCY AND EXIT LIGHTS MUST BE ON THE SAME | | | CIRCUIT AS THE LIGHTS IN THE SAME AREA. PROVIDE | | | CORRECTION. NEC 700.12(F) | | | 8. PROVIDE REQUIRED SIGN CIRCUIT, WITH CONTROLS PER THE | | | FBC ENERGY CODE. NEC 600.5, FBC C405.2.4 | | | 9. PROVIDE SHOW WINDOW OUTLETS IF APPLICABLE. NEC | | | 210.62 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-08-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-08-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-08-11 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-07-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-07-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-07-21 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2017-07-24 10:12:23 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) ADDRESS ELECTRICAL COMMENTS PER NFPA 70, | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-08-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-08-22 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-08-04 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-07-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-25 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-14 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-09 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-09 |
Time |
17:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-24 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-24 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2017-07-24 15:13:44 | 1ST REVIEW FBC-2014 MECHANICAL | | | REVISION PERMIT #17070579 | | | MASTER #16110180 | | | 7/24/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-1: A MINIMUM 10' CLEARANCE BETWEEN THE ERV | | | EXHAUST OUTLETS AND AIR INTAKES ARE REQUIRED PER | | | SECTION 501.3.1 (3). PLEASE VERIFY COMPLIANCE BY | | | PLACING THE CLEARANCE DISTANCE MEASUREMENTS ON THE | | | PLAN. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-07-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-21 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-21 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
|