Plan Review Details - Permit 17070542
Plan Review Stops For Permit 17070542
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-10-18 Cont ID  
Sent By jwitmer Date 2017-10-18 Time 08:24 Rev Time 0.00
Received By jwitmer Date 2017-10-18 Time 07:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-07-19 Cont ID  
Sent By jwitmer Date 2017-07-19 Time 14:27 Rev Time 0.00
Received By jwitmer Date 2017-07-19 Time 13:13 Sent To FIRE
Notes
2017-07-19 14:25:45BUILDING PLAN REVIEW
 W. P. B. REVISION: 17070542
 W. P. B. PERMIT: 16060181
 ADD: 1301 MERCER AVE.
 CONT: STOR-ALL CONSTRUCTION
 TEL: 954-421-7888
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: WED. JULY 19/ 2017
  
 ACTION: DENIED./ STANLEY SLIDING DOORS.
  
 1) SHEETS A-11 & A-41 BOTH SHOW THE FRONT ENTRY OF THE
 STORAGE BUILDING. THERE ARE (2) ENTRY DOORS ONE FOR
 ENTRY INTO THE LOBBY (DOOR LB-100) AND A SECOND DOOR
 INTO THE OFFICE AREA (DOOR OF-100) THE HARDWARE
 SCHEDULE SHEET A-53 FOR THESE 2 ENTRY DOORS INDICATES
 THE TYPE OF HARDWARE, 1 CYLINDER LOCK-KEYED EXTERIOR
 AND A THUMB TURN ON THE INTERIOR. NO MENTION OF ANY
 FIRE/ PANIC HARDWARE ON EITHER OF THESE DOORS. THE
 FBC-B SECTION 1008.1.10 REQUIRES PANIC AND OR FIRE EXIT
 HARDWARE ON DOORS SERVING AN OCCUPANT LOAD OF 50 OR
 MORE. THE EXCEPTION 1008.1.9.3, ITEM 2 IS THE EXCEPTION
 TO THIS RULE.
  
 THE SUBMITTED PRODUCT APPROVAL STANLEY ACCESS AUTOMATIC
 SLIDING DOORS HAS (2) OPTIONS SERIES 2000 AND SERIES
 3000. SERIES 2000 HAS ONLY A HORIZONTAL MUNTIN BAR
 (17-18) WHEREAS THE SERIES 3000 INDICATES PANIC
 HARDWARE. NOTE 2 ON THE TECHNICAL SHEET NUMBER 3, NOTES
 HORIZONTAL MUNTIN BAR NOT REQUIRED EXCEPT AT PANIC BAR.
 PLEASE CLARIFY THE INTENSION FOR THE STANLEY SLIDING
 DOORS.
  
 PLEASE ALSO NOTE THAT THE EXCEPTION FOR PANIC HARDWARE
 ON THE MAIN ENTRY DOORS MUST MEET ALL OF THE
 REQUIREMENTS UNDER SECTION 1008.1.9.3(2).
 2. IN BUILDINGS IN OCCUPANCY GROUP A HAVING AN OCCUPANT
 LOAD OF 300 OR LESS, GROUPS B, F, M AND S, AND IN
 PLACES OF RELIGIOUS WORSHIP, THE MAIN EXTERIOR DOOR OR
 DOORS ARE PERMITTED TO BE EQUIPPED WITH KEY-OPERATED
 LOCKING DEVICES FROM THE EGRESS SIDE PROVIDED:
  
 2.1. THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS
 LOCKED;
  
 2.2. A READILY VISIBLE DURABLE SIGN IS POSTED ON THE
 EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: THIS
 DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. THE
 SIGN SHALL BE IN LETTERS 1 INCH (25 MM) HIGH ON A
 CONTRASTING BACKGROUND; AND
  
 2.3. THE USE OF THE KEY-OPERATED LOCKING DEVICE IS
 REVOKABLE BY THE BUILDING OFFICIAL FOR DUE CAUSE.
  
 PLEASE CLARIFY WHAT HARDWARE IS TO BE INSTALLED ON THE
 STANLEY SLIDING DOORS? IF A THE REQUIREMENTS UNDER
 FBC-B 1008.1.9.3(2) ARE GOING TO APPLY?
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-10-11 Cont ID  
Sent By pleduc Date 2017-10-11 Time   Rev Time 0.00
Received By pleduc Date 2017-10-10 Time 16:10 Sent To B
Notes
2017-10-10 16:53:50THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THE EXIT DOOR LOCKS AND HARDWARE SHALL MEET THE
 REQUIRERMENTS OF NFPA 101, CHAPTER 7, MEANS OF EGRESS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-07-21 Cont ID  
Sent By pleduc Date 2017-07-21 Time   Rev Time 0.00
Received By pleduc Date 2017-07-21 Time 11:30 Sent To  
Notes
2017-07-21 11:35:35THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
  
 1) THERE ARE NO PLAN SHEETS SHOWING WHERE THE DOORS
 WILL BE INSTALLED.
  
 PLEASE PROVIDE.
  
  
 2) THERE IS NO DOOR SCHEDULE INDICATING EXIT HARDWARE,
 PANIC BARS, LOCKING DEVICES, ETC.
  
 PLEASE PROVIDE IN COMPLIANCE WITH THE MASTER PERMIT AND
 NFPA 101, CHAPTER 7, MEANS OF EGRESS.
  
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-10-18 Cont ID  
Sent By jwitmer Date 2017-10-18 Time 08:25 Rev Time 0.00
Received By jwitmer Date 2017-10-06 Time 13:02 Sent To  
Notes
2017-10-10 13:03:12RESUB ROUTED TO FIRE INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-10 Cont ID  
Sent By lmarchan Date 2017-10-10 Time 12:59 Rev Time  
Received By lmarchan Date 2017-07-14 Time   Sent To  
Notes
***NONE***