| 2017-09-13 11:57:32 | 1ST REVIEW: FBC 2014 5TH ED |
| | CITY CODE SECTION 78-490 |
| | |
| | NOT APPROVED, SEE BELOW: |
| | |
| | 1) ALTHOUGH YOU PROVIDED A PARKLET PERMIT APPLICATION, |
| | PLEASE ADDITIONALLY PROVIDE A BUILDING PERMIT |
| | APPLICATION FORM WITH CONTRACTOR AND OWNER INFORMATION |
| | AND SIGNATURES. LIST THE CITY OF WEST PALM BEACH IN BOX |
| | 9 ON THE REAR OF THE APPLICATION. |
| | |
| | 2) PROVIDE TWO SETS OF PLANS, ONLY ONE WAS FOUND. |
| | |
| | 3) CITY CODE 78-497 (B)()C. - WIND RESISTANCE - SPECIFY |
| | THE WIND RESISTANCE STANDARD UTILIZED IN THE DESIGN OF |
| | THE PARKLET. PROVIDE DETAILS FOR FASTENING SUCH AS NAIL |
| | TYPE & SPACING, CONNECTORS AND CONNECTION TO EARTH. IS |
| | THERE INTENT TO DESIGN FOR WIND RESISTANCE PURSUANT TO |
| | FBC CHAPTER 16 FOR THE LOCATION AS RISK CATEGORY II OR |
| | IS THE DESIGN TO BE OF A LESSER WIND RESISTANCE WITH |
| | INTEND TO REMOVE IN THE EVENT OF FORCASTED HIGH WINDS. |
| | IF THE LATER, PROVIDE DETAILS FOR THE MAXIMUM WIND |
| | DESIGN. FOR EXAMPLE, IF THE INTENT IS TO REMOVE PRIOR |
| | TO FORECASTED 75 MPH WINDS, PROVIDE A DESIGN CAPABLE OF |
| | WITHSTANDING 90 MPH WINDS AND PROVIDE THE REMOVAL PLAN. |
| | |
| | 4) CITY CODE 78-497 (B)(1)F. - ACCESSIBILITY - PLEASE |
| | INDICATE THE INTENT TO COMPLY WITH FBC ACCESSIBILITY |
| | CHAPTER 3 AS TO APPROACH, GROUND SURFACES, OPENINGS IN |
| | FLOOR SURFACES, CHANGES IN LEVEL, AND TURNING SPACE, |
| | MANEUVERING, AND CLEARANCES AND TABLE TOP HEIGHTS PER |
| | CHAPTER 3. ADDITIONALLY, PROVIDE A SEATING PLAN TO SHOW |
| | COMPLIANCE WITH FBC ACCESSIBILITY TABLE 221.2.1.1 |
| | |
| | STEVEN KENNEDY, CBO |
| | ASSISTANT BUILDING OFFICIAL |
| | (561) 805-6710 |
| | [email protected] |
| | |