Plan Review Details - Permit 17070450
| Plan Review Stops For Permit 17070450 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-10-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-10-20 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-10-20 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2017-10-20 15:14:06 | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING | | | REVIEW CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | NOTE: | | | ENGINEER OF RECORD MAY BE CHARGED 4 TIMES THE PLAN | | | REVIEW FEE AS REQUIRED BY FLORIDA STATUTE 553.80(2)(B) | | | FOR MULTIPLE PLANS REJECTIONS. | | | | | | 1- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | | THE UNIFIED LAND DEVELOPMENT CODE. | | | RESPONSE: REPEAT COMMENT. AFTER PLANS ARE REVISED BY | | | THE ENGINEER, BRING THEM TO PALM BEACH COUNTY FOR | | | IMPACT FEES ASSESSMENT. | | | | | | 2- PROPOSED EGRESS WINDOW DOESN'T COMPLY WITH THE | | | EGRESS REQUIREMENTS OF SEC. R310 FBC-RESIDENTIAL. 5TH | | | EDITION (2014). NEED TO COMPLY WITH THE MINIMUM WIDTH | | | OPENING, MINIMUM HEIGHT OPENING AND MINIMUM TOTAL CLEAR | | | OPENING. SEE SEC. R310 FBC-RESIDENTIAL, 5TH EDITION | | | (2014) AND REVISE AS REQUIRED. SH-33 DOESN'T COMPLY. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. NOTE: REVISE | | | SIZE OF WINDOW AND CLEARLY SPECIFY SIZE. SEE PRODUCT | | | APPROVAL FOR STANDARD SIZES. | | | | | | 3- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | | BY SEC. R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | 4- PLANS NEED TO PROVIDE INFORMATION SHOWING COMPLIANCE | | | WITH THE HEATING REQUIREMENTS OF SEC. R303.9 | | | FBC-RESIDENTIAL. NOTE: PORTABLE HEATERS ARE NOT | | | ALLOWED. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | 5- NEW BATHROOM WINDOW TO COMPLY WITH THE SAFETY | | | GLAZING REQUIREMENTS OF SEC. R308.4.5 FBC-RESIDENTIAL | | | IF THE WINDOW DOESN'T HAVE IMPACT GLASS. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. WINDOWS | | | PRODUCT APPROVAL WAS NOT SUBMITTED. UNABLE TO VERIFY IF | | | WINDOWS ARE GOING TO BE IMPACT RESISTANT OR NOT. | | | | | | 6- PROVIDE DETAILS AND SPECIFICATIONS SHOWING HOW THE | | | NEW CONCRETE BLOCK WALL IS ATTACHED TO THE EXISTING | | | WOOD BEAM. SEC. R301.1 FBC-RESIDENTIAL. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | 7- TYPICAL WALL SECTION: SPECIFY FOOTING REINFORCEMENT. | | | SEC. R301.1 FBC-RESIDENTIAL. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | 8- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR; | | | A) SINGLE HUNG WINDOWS AS SPECIFIED ON PLANS. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | B) WINDOW MULLION AS SPECIFIED ON PLANS. AND, SPECIFY | | | MULLION SIZE TO VERIFY COMPLIANCE WITH SEC. R301.1 | | | FBC-RESIDENTIAL. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | C) ARCHED FIXED WINDOW AS SPECIFIED ON PLANS. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | D) PRECAST LINTELS AS SPECIFIED ON PLANS. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | E) HURRICANE SHUTTERS IF THE WINDOWS PRODUCT APPROVALS | | | DON'T HAVE HURRICANE IMPACT GLASS. AND, PROVIDE | | | COMPLETE INSTALLATION SCHEDULE. SEE CITY SAMPLE. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | 9- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | 10- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT (EVEN FOR OWNER | | | BUILDER) AND ALL DESIGN PROFESSIONAL FEES AS REQUIRED | | | BY SEC. 1098.3 CITY AMENDMENTS. REVISE VALUATION AS | | | REQUIRED. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | *******ENGINER TO PROVIDE RESPONSE LETTER ADDRESING | | | EACH COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-09 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-08 |
Time |
18:16 |
Sent To |
|
|
| Notes |
| 2017-08-08 18:22:34 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW | | | COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | | THE UNIFIED LAND DEVELOPMENT CODE. | | | | | | 2- PROPOSED EGRESS WINDOW DOESN'T COMPLY WITH THE | | | EGRESS REQUIREMENTS OF SEC. R310 FBC-RESIDENTIAL. 5TH | | | EDITION (2014). NEED TO COMPLY WITH THE MINIMUM WIDTH | | | OPENING, MINIMUM HEIGHT OPENING AND MINIMUM TOTAL CLEAR | | | OPENING. SEE SEC. R310 AND REVISE AS REQUIRED. | | | | | | 3- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | | BY SEC. R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | | | | 4- PLANS NEED TO PROVIDE INFORMATION SHOWING COMPLIANCE | | | WITH THE HEATING REQUIREMENTS OF SEC. R303.9 | | | FBC-RESIDENTIAL. NOTE: PORTABLE HEATERS ARE NOT | | | ALLOWED. | | | | | | 5- NEW BATHROOM WINDOW TO COMPLY WITH THE SAFETY | | | GLAZING REQUIREMENTS OF SEC. R308.4.5 FBC-RESIDENTIAL | | | IF THE WINDOW DOESN'T HAVE IMPACT GLASS. | | | | | | 6- PROVIDE DETAILS AND SPECIFICATIONS SHOWING HOW THE | | | NEW CONCRETE BLOCK WALL IS ATTACHED TO THE EXISTING | | | WOOD BEAM. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 7- WINDOW BUCK DETAIL: ENGINEER OF RECORD NEEDS TO | | | SPECIFY ANCHOR TYPE AND SPACING FOR THE BUCK FASTENING. | | | SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 8- TYPICAL WALL SECTION: SPECIFY FOOTING REINFORCEMENT. | | | SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 9- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR; | | | A) SINGLE HUNG WINDOWS AS SPECIFIED ON PLANS. | | | | | | B) WINDOW MULLION AS SPECIFIED ON PLANS. AND, SPECIFY | | | MULLION SIZE TO VERIFY COMPLIANCE WITH SEC. R301.1 | | | FBC-RESIDENTIAL. | | | | | | C) ARCHED FIXED WINDOW AS SPECIFIED ON PLANS. | | | | | | D) PRECAST LINTELS AS SPECIFIED ON PLANS. | | | | | | E) HURRICANE SHUTTERS IF THE WINDOWS PRODUCT APPROVALS | | | DON'T HAVE HURRICANE IMPACT GLASS. AND, PROVIDE | | | COMPLETE INSTALLATION SCHEDULE. SEE CITY SAMPLE. | | | | | | 10- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 11- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT (EVEN FOR OWNER | | | BUILDER) AND ALL DESIGN PROFESSIONAL FEES AS REQUIRED | | | BY SEC. 1098.3 CITY AMENDMENTS. REVISE VALUATION AS | | | REQUIRED. | | | | | | *******ENGINER TO PROVIDE RESPONSE LETTER ADDRESING | | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-10-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-25 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-25 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2017-10-25 14:12:21 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | (COMMENTS NOT ADDRESSED ARE NOTED IN PARANTHESES). | | | | | | 1. PROVIDE FLOOR PLAN FOR ENTIRE RESIDENCE, SHOWING | | | LOCATION OF EXISTING SMOKE ALARMS. IF NONE ARE | | | EXISTING, OR NOT TO CODE, SHOW AS NEW INSTALLATION. | | | PROVIDE SMOKE ALARM IN THE IMMEDIATE VICINITY OUTSIDE | | | THE NEW BEDROOM. FBC R314.3, R314.3.1; FBC 107.2.1 | | | (REPEAT COMMENT: NOT ADDRESSED) | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC | | | RE3706.2, RE3902 (REPEAT COMMENT: NOT ADDRESSED) | | | 3. PROVIDE LOAD CALCULATION TO CONFIRM EXISTING SERVICE | | | IS ADEQUATE FOR THE ADDITIONAL LOAD. NEC 220; FBC | | | RE3602.1 (REPEAT COMMENT: NOT ADDRESSED) | | | 4. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC | | | 215.5; FBC 107.2.1 (REPEAT COMMENT: NOT ADDRESSED) | | | 5. PROVIDE AFCI PROTECTION PER CODE: "ALL 120-VOLT, | | | SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS | | | SUPPLYING OUTLETS IN DWELLING UNIT FAMILY ROOMS, DINING | | | ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, | | | HALLWAYS, OR SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI | | | PROTECTION". NEC 210.12; FBC RE3902.12 (REPEAT COMMENT: | | | NOT ADDRESSED) | | | 6. PROVIDE DEDICATED 20 AMP CIRCUIT FOR BATH GFCI | | | OUTLET: "A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT | | | SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE | | | OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS". | | | NEC 210.11(C)(3) , FBC RE3703.4 (REPEAT COMMENT: NOT | | | ADDRESSED) | | | 7. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE4002.14 (REPEAT | | | COMMENT: NOT ADDRESSED) | | | 8. PROVIDE RECEPTACLES PER THE NEC WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. NEC 210.52; FBC RE3901.2.1 | | | (REPEAT COMMENT: NOT ADDRESSED) | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-07-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-28 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-28 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2017-07-28 10:52:44 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE FLOOR PLAN FOR ENTIRE RESIDENCE, SHOWING | | | LOCATION OF EXISTING SMOKE ALARMS. IF NONE ARE | | | EXISTING, OR NOT TO CODE, SHOW AS NEW INSTALLATION. | | | PROVIDE SMOKE ALARM IN THE IMMEDIATE VICINITY OUTSIDE | | | THE NEW BEDROOM. FBC R314.3, R314.3.1; FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC | | | RE3706.2, RE3902 | | | 3. PROVIDE LOAD CALCULATION TO CONFIRM EXISTING SERVICE | | | IS ADEQUATE FOR THE ADDITIONAL LOAD. NEC 220; FBC | | | RE3602.1 | | | 4. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC | | | 215.5; FBC 107.2.1 | | | 5. PROVIDE AFCI PROTECTION PER CODE: "ALL 120-VOLT, | | | SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS | | | SUPPLYING OUTLETS IN DWELLING UNIT FAMILY ROOMS, DINING | | | ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, | | | HALLWAYS, OR SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI | | | PROTECTION". NEC 210.12; FBC RE3902.12 | | | 6. PROVIDE DEDICATED 20 AMP CIRCUIT FOR BATH GFCI | | | OUTLET: "A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT | | | SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE | | | OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS". | | | NEC 210.11(C)(3) , FBC RE3703.4 | | | 7. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE4002.14 | | | 8. PROVIDE RECEPTACLES PER THE NEC WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. NEC 210.52; FBC RE3901.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-10-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-10-25 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-10-03 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-09 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-07-12 |
Time |
13:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2017-10-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-10-20 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-10-20 |
Time |
15:40 |
Sent To |
E |
|
| Notes |
| 2017-10-20 15:41:14 | 1- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | | THE UNIFIED LAND DEVELOPMENT CODE. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-09 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-09 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2017-08-09 10:48:52 | 1- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | | THE UNIFIED LAND DEVELOPMENT CODE. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-10-13 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-10-13 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-10-13 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-07-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-07-25 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-07-25 |
Time |
06:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-10-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2017-10-11 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-10-11 09:26:40 | *****************************ZONING | | | REVIEW******************************* | | | | | | PLEASE PROVIDE A COPY OF THE SURVEY, HIGHLIGHTING THE | | | CONVERTED AREA. IS THE BUILDING FOOTPRINT EXPANDING? | | | | | | PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | [email protected] | | | 561-822.1449 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2017-08-02 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2017-08-07 15:24:33 | *****************************ZONING | | | REVIEW******************************* | | | | | | PLEASE PROVIDE A COPY OF THE SURVEY, HIGHLIGHTING THE | | | CONVERTED AREA. IS THE BUILDING FOOTPRINT EXPANDING? | | | | | | PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | [email protected] | | | 561-822.1449 |
|
|
|