|
 |
 |
 |
 |
 |
Plan Review Details - Permit 17061378
| Plan Review Stops For Permit 17061378 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-07-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-07-07 |
Time |
15:53 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2017-07-07 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-07-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-19 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-19 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-07-12 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-12 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-12 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2017-07-12 14:31:06 | | | | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS: | | | | | | 1. PROVIDE ELECTRICAL PLAN SIGNED AND SEALED BY DESIGN | | | PROFESSIONAL OR SIGNED BY THE ELECTRICAL CONTRACTOR | | | QUALIFIER. FS 471.003(2)(H); 471.025; FBC 107.2.1, | | | FAC61G15-23 | | | 2. PROVIDE PANEL SCHEDULE SHOWING ANY NEW OR ALTERED | | | CIRCUITS AND THE APPROPRIATE AFCI OR GFCI PROTECTION AS | | | REQUIRED. NEC 215.5, FBC 107.2.1 | | | 3. PROVIDE LOCATION OF EXISTING GFCI OUTLETS IN | | | KITCHEN. IF NOT TO CODE CURRENTLY, SHOW AS NEW | | | LOCATIONS. NEC 210.52 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-07-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-19 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-17 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2017-07-18 13:57:11 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-06-30 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-14 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-14 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-07-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-13 |
Time |
19:19 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-13 |
Time |
17:12 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |