Plan Review Details - Permit 17061339
| Plan Review Stops For Permit 17061339 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2017-07-28 |
|
|
Cont ID |
|
| Sent By |
hhall |
Date |
2017-07-28 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
hhall |
Date |
2017-07-28 |
Time |
07:31 |
Sent To |
I |
|
| Notes |
| 2017-07-28 07:34:15 | PROVISOS: | | | 1. LEAD FREE INSTALL FOR BACKFLOWS & FILLINGS | | | 2. USE APPROVED BACKFLOWS |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
mkhan |
Date |
2017-07-05 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
mkhan |
Date |
2017-07-05 |
Time |
15:59 |
Sent To |
I |
|
| Notes |
| 2017-07-05 16:00:46 | PLEASE PROVIDE SPECS FOR BACKFLOW PREVENTER. | | | | | | NOTE THAT BACKFLOW PREVENTER SHALL BE USC APPROVED LEAD | | | FREE TYPE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-07-28 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-07-14 |
Time |
12:44 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-06-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-06-30 |
Time |
13:54 |
Sent To |
M |
|
| Notes |
| 2017-06-30 15:06:45 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) IT IS UNCLEAR ON THE SUBMITTED PLAN, IS FARMER & | | | IRWIN THE ENGINEER OF RECORD, IF SO THERE IS NO | | | INDICATIORS PER 61G15-32.003 COMMON REQUIREMENTS TO ALL | | | FIRE PROTECTION ENGINEERING DOCUMENTS & 61G15-32.004 | | | DESIGN OF WATER BASED FIRE PROTECTION SYSTEMS. | | | | | | PLEASE CORRECT OR CLARIFY IF A STAMP OR SEAL OR | | | APPROVAL OF THE EOR IS REQUIRED. | | | | | | | | | | | | 2) IT IS NOT CLEAR WHERE THE INSTALLATION STARTS AND OR | | | STOPS. THE PLAN ARE TOO SMALL TO CLEARLY IDENTIFFY, | | | | | | PLEASE CORRECT. | | | | | | | | | | | | 3) THERE WERE NO MANUFACTURES SPECIFICATION/INSTALLTION | | | SHEETS PROVIDED. | | | | | | PLEASE PROVIDE THEM. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-07-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-07-28 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-07-12 |
Time |
13:03 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-07-06 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-07-06 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-06-29 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2017-06-30 09:28:34 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-07-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-27 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-27 |
Time |
12:00 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-07-03 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-07-03 |
Time |
13:35 |
Sent To |
ENG |
|
| Notes |
| 2017-07-03 14:23:12 | PLAN DENIED | | | 1) REFER TO SECTION 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR | | | THE DESIGN. 2014 LOCAL AMENDMENTS TO THE FLORIDA | | | BUILDING CODE | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
|