Plan Review Details - Permit 17061119
Plan Review Stops For Permit 17061119
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-07-15 Cont ID  
Sent By cthroop Date 2017-07-15 Time 12:20 Rev Time 0.00
Received By cthroop Date 2017-07-15 Time 12:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-07-10 Cont ID  
Sent By cthroop Date 2017-07-10 Time 09:59 Rev Time 0.00
Received By cthroop Date 2017-07-10 Time 09:49 Sent To HIST
Notes
2017-07-10 10:20:09BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. IN ADDITION TO ROUGH OPENINGS, THE WINDOW SCHEDULE
 SHALL INCLUDE THE FOLLOWING INFORMATION:
  
 FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF
 THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND
 DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1.
 WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL
 MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING,
 THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH
 PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE
 WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR
 HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED
 TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR
 WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR
 WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN
 GARAGE DOORS).
  
 2. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE
 THEIR PRINTED NAME AND SIGNATURE ON THE SUBMITTED PLANS
 AND SUPPORTING DOCUMENTS PER FBC 107.
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2017-07-10 Cont ID  
Sent By cthroop Date 2017-07-10 Time 09:49 Rev Time 0.00
Received By cthroop Date 2017-07-10 Time 09:49 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2017-07-12 Cont ID  
Sent By cpuell Date 2017-07-12 Time 10:44 Rev Time 0.00
Received By destabro Date 2017-07-12 Time 09:49 Sent To B
Notes
2017-07-12 09:50:287/12/2017 - REAR INTERIOR REMODEL AND DOOR/WINDOW
 REPLACEMENT (IN AFFECTED AREA ONLY) APPROVED BY
 FRIEDERIKE MITTNER, CITY HISTORIC PRESERVATION PLANNER.
 PRODUCT APPROVALS (WHITE FRAME ALUMINUM) MEET DESIGN
 GUIDELINES FOR HISTORIC DISTRICT. DLE
2017-07-10 15:34:53ROUTED TO DESIREE ESTABROOK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-07-15 Cont ID  
Sent By cthroop Date 2017-07-15 Time 12:20 Rev Time 0.00
Received By cthroop Date 2017-07-13 Time 16:11 Sent To  
Notes
2017-07-14 16:12:10CTHROOP'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-07-12 Cont ID  
Sent By cpuell Date 2017-07-12 Time 10:44 Rev Time 0.00
Received By cpuell Date 2017-06-28 Time 14:15 Sent To HIST
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-06-27 Cont ID  
Sent By skennedy Date 2017-06-27 Time 14:08 Rev Time 0.00
Received By skennedy Date   Time 14:08 Sent To  
Notes
2017-06-27 14:18:04THIS IS TO NOTIFY THE APPLICANT THAT THE APPLICATION IS
 DEFICIENT AND THAT REVIEW WILL NOT COMMENCE BEYOND THIS
 DETERMINATION OF DEFICIENCY. THE DESCRIPTION STATES
 RENOVATION YET NO PLANS ARE SUPPLIED. APPLICATION
 ADDITIONALLY STATES INSTALLATION OF IMPACT WINDOWS, BUT
 DOES NOT QUANTIFY OR DESCRIBE ANY ADDITIONAL
 INFORMATION AS WOULD BE PROVIDED NORMALLY WITH A KEY
 PLAN AND A WINDOW SCHEDULE AND INFORMATION RELATIVE TO
 EGRESS REQUIREMENTS. PLEASE SUPPLY PLANS AND
 SPECIFICATIONS SUFFICIENT TO DETERMINE AND EVALUATE THE
 SCOPE OF WORK AND CODE COMPLIANCE.
  
 553.792? BUILDING PERMIT APPLICATION TO LOCAL
 GOVERNMENT.
 (1)?WITHIN 10 DAYS OF AN APPLICANT SUBMITTING AN
 APPLICATION TO THE LOCAL GOVERNMENT, THE LOCAL
 GOVERNMENT SHALL ADVISE THE APPLICANT WHAT INFORMATION,
 IF ANY, IS NEEDED TO DEEM THE APPLICATION PROPERLY
 COMPLETED IN COMPLIANCE WITH THE FILING REQUIREMENTS
 PUBLISHED BY THE LOCAL GOVERNMENT.
  
 FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
  
 FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
 THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE,
 SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO
 RECORDS MANAGEMENT.
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2017-07-10 Cont ID  
Sent By cthroop Date 2017-07-10 Time 09:49 Rev Time 0.00
Received By cthroop Date 2017-07-10 Time 09:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2017-07-10 Cont ID  
Sent By cthroop Date 2017-07-10 Time 09:49 Rev Time 0.00
Received By cthroop Date 2017-07-10 Time 09:49 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy