Plan Review Details - Permit 17061108
Plan Review Stops For Permit 17061108
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-06-27 Cont ID  
Sent By jgomez Date 2017-06-27 Time 10:22 Rev Time 0.00
Received By jgomez Date 2017-06-27 Time 07:47 Sent To  
Notes
2017-06-26 11:09:34RESIDENTIAL (?) ALTERATION, SECOND BUILDING REVIEW
 CHECKLIST FOR DETACHED STRUCTURE.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE:
 DESIGN PROFESSIONAL MAY BE CHARGED FOUR TIMES THE PLAN
 REVIEW FEES AS REQUIRED BY FLORIDA STATUTE 553.80(2)(B)
 FOR FUTURE SUBMITTALS WHEN THEY ARE DENIED 3 OR MORE
 TIMES.
  
  
 ORIGINAL COMMENT:
 1- PROPOSED USE OF THESE BUILDINGS IS NOT CLEAR.
 PROPOSED SITE PLAN SHOWS TWO EXISTING BUILDINGS WITH
 PARKING FOR 5 CARS, INCLUDING PARKING FOR A HANDICAPPED
 PERSON. THIS PARKING LAYOUT IS TYPICAL FOR COMMERCIAL
 USE. FLOOR PLANS SUBMITTED SHOW A LAYOUT FOR A SINGLE
 FAMILY RESIDENCE. CLEARLY IDENTIFY THE PROPOSED USED OF
 EACH BUILDING. NOTE: THE EXISTING USE IS A SINGLE
 FAMILY RESIDENCE WITH A DETACHED GARAGE. IDENTIFY THE
 USE OF EACH BUILDING FOR PROPER PLAN REVIEW. SEC. 102.2
 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. CLEARLY IDENTIFY TYPE OF RESIDENTIAL
 USE. SEE SEC. 310 FBC -BUILDING, 5TH EDITION AND REVISE
 AS REQUIRED. THE PROPOSED USE OF THE DETACHED STRUCTURE
 IS NOT CLEAR. IS IT A SINGLE FAMILY RESIDENCE OR
 BUSINESS. FLOOR PLAN SHOWN ON SHEET 2 OF 4 DOESN'T HAVE
 A NAME IDENTIFYING WHAT IS THE MAIN ROOM USED FOR.
 NOTE: ACCORDING TO ZONING, COMMERCIAL USE IS NOT
 ALLOWED. NEED ZONING APPROVAL FOR PROPOSED USE.
 BUILDING REVIEW CAN NOT BE PERFORMED IF SPECIFIC USE IS
 NOT PROVIDED. REVISE INFORMATION IN SHEET 2 OF 4.
 COORDINATE WITH ZONING. IF BUSINESS IS ALLOWED, THEN
 CLEARLY SPECIFY TYPE OF BUSINESS FOR PROPER BUILDING
 REVIEW. NOTE: PARKING LAYOUT AND ACCESSIBILITY DETAILS
 AND SPECIFICATIONS ARE NO REVIEWED BECAUSE THEY DON'T
 APPLY TO SINGLE FAMILY RESIDENCES. THESE WILL BE
 REVIEWED FOR COMPLIANCE IF ZONING APPROVES A COMMERCIAL
 USE FOR HIS PROPERTY AND THE PLANS ARE CLEAR ON THE
 PROPOSED USE.
  
 2- PROVIDE ENERGY CALCULATIONS (2 COPIES). SEC.
 R101.4.4 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 3- SHEET 2 OF 4:
 A) LEVEL OF ALTERATION SPECIFIED IS NOT LEVEL 2. THIS
 IS A CHANGE OF OCCUPANCY. REVISE AS REQUIRED. SEC. 506
 FBC-EXISTING BUILDING, 5TH EDITION (2014).
  
 B) THE TYPE OF CONSTRUCTION IS NOT TYPE 4. SEE SEC.
 602.1 FBC-BUILDING, 5TH EDITION (2014) AND REVISE AS
 REQUIRED.
  
 C) GROUP OCCUPANCY IS NOT 2. SEE SEC. 302.1
 FBC-BUILDING, 5TH EDITION (2014) AND REVISE AS
 REQUIRED.
  
 4- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
  
 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) EXTERIOR DOOR AS SHOWN ON PLANS.
  
 B) SINGLE HUNG WINDOWS AS SHOWN ON PLANS.
  
 C) SHUTTERS, IF DOOR AND WINDOWS DON'T HAVE IMPACT
 GLAZING. AND PROVIDE COMPLETE INSTALLATION SCHEDULE.
 SEE CITY SAMPLE.
  
 D) ALL STRUCTURAL CONNECTORS SPECIFIED ON FRAMING
 DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND PAE SHOWING THE SPECIFIED CONNECTOR OR
 ENGINEER OF RECORD TO LIST THE FLORIDA PRODUCT APPROVAL
 NUMBER NEXT TO EACH CONNECTOR.
  
 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 6- SPECIFY THE VALUATION FOR ALL THE SCOPE OF WORK
 SHOWN ON PLANS. VALUATION TO INCLUDE ALL LABOR,
 MATERIALS, CONTRACTOR'S OVERHEAD AND PROFIT AND ALL
 DESIGN PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS.
  
 7- SHEET 1 OF 4:
 A) CLEARLY SPECIFY THE OCCUPANCY USE/TYPE SPECIFIED ON
 THE WIND INFORMATION ON THE UPPER RIGHT SIDE OF SHEET 1
 OF 4. CLEARLY DEFINE WHAT TYPE OF "RESIDENTIAL
 DWELLING" IS THE PROPOSED USE OF THIS BUILDING.
 COORDINATE WITH ITEM # 1 ABOVE. SEC. 310 FBC-BUILDING.
  
 B) SPECIFY THE INTERNAL PRESSURE COEFFICIENT ON THE
 WIND INFORMATION. SEC. R301.1 FBC-RESIDENTIAL.
  
 C) THIS IS A CHANGE OF USE. THIS STRUCTURE WAS A
 GARAGE. THIS IS NOT LEVEL OF ALTERATION 2. THIS WILL BE
 CHANGE OF OCCUPANCY. SEC. 506 FBC-EXISTING BUILDING,
 5TH EDITION (2014). REVISE AS REQUIRED. COORDINATE WITH
 ITEM #1 ABOVE.
  
 D) REVISE THE WINDOWS DESIGN PRESSURES TABLE SHOWN ON
 THE UPPER RIGHT CORNER. NEED TO SPECIFY THE DESIGN
 PRESSURES FOR THE EFFECTIVE WIND AREA OF EACH WINDOW AS
 REQUIRED BY TABLE R301.2(2) FBC-RESIDENTIAL. USE THE
 LOWEST EFFECTIVE AREA OF 10 S.F. AS SHOWN ON TABLE
 R301.2(2) FOR INDIVIDUAL WINDOWS THAT ARE 10 S.F. OR
 LESS (OR PROVIDE THE ACTUAL CALCULATIONS). ALSO, THE
 DOOR IS LOCATED IN THE END ZONE NOT INTERIOR ZONE.
 REVISE AS REQUIRED.
  
 8- DETAIL 2/3 ON SHEET 3 OF 4:
 A) SPECIFY THE STRUCTURAL CONNECTORS AT THE ENDS OF ALL
 STRUCTURAL MEMBERS. (VERTICALLY AND HORIZONTALLY). SEC.
 R301.1 FBC-RESIDENTIAL.
  
 B) CLARIFY HOW IS THE NEW HEAD HEADER SUPPORTED ON THE
 FRAMING WALL. WHY THERE IS NOT STUD SUPPORTING THE ENDS
 OF THE HEADER. WHY THERE IS ONLY ONE BEARING STUD. SEC.
 R301.1 FBC-RESIDENTIAL.
  
 9- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE HEATING REQUIREMENTS OF SEC. R303.9
 FBC-RESIDENTIAL.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS..
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-06-28 Cont ID  
Sent By jpearson Date 2017-06-28 Time 08:53 Rev Time 0.00
Received By jpearson Date 2017-06-28 Time 08:53 Sent To  
Notes
2017-06-28 08:54:13CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 ELECTRICAL REVIEW COMMENTS:
  
 1. SHOW PANEL AND SERVICE LOACTION ON PLAN. FBC 107.2.1
 2. SHOW COMPLIANCE WITH FBC ENERGY CONSERVATION FOR
 LIGHTING AND POWER OUTLETS. C401.2.1
 3. PROVIDE ACCURATE LOAD CALCULATION FOR EACH
 STRUCTURE, INCLUDING ALL LOADS REQUIRED PER CODE. NEC
 220
 4. EACH STRUCTURE WILL REQUIRE SEPARATE PERMIT, PROVIDE
 AS REQUESTED PREVIOUSLY. FBC 105.1
 5. IT APPEARS THAT THERE ARE SEVERAL CIRCUITS FEEDING
 THE DETACHED GARAGE FROM THE HOUSE PANEL. PER CODE: "A
 BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A BRANCH
 CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE
 DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE
 FEEDER OR BRANCH CIRCUIT". PROVIDE CORRECTION. NEC
 225.30
 6. PROVIDE GROUNDING ELECTRODE SYSTEM FOR BUILDING
 SUPPLIED BY A FEEDER. NEC 250.32
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-06-30 Cont ID  
Sent By pleduc Date 2017-06-30 Time   Rev Time 0.00
Received By pleduc Date 2017-06-30 Time 10:53 Sent To  
Notes
2017-06-30 11:29:26THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THE SUBMITTED PLAN APPLICATION STATES "CHANGE OF
 USE". THE PLAN SHEETS INDICATED A SINGLE FAMILY HOME
 BUSINESS. THE BUSINESS IS NOT INDICATED.
  
 THE OCCUPANCY CLASSIFICATION MUST BE PROVIDED IN ORDER
 TO ASSESS THE APPLICABLE FLORIDA FIRE PREVENTION CODE,
 OCCUPANCY CLASSIFICATION, REQUIRERMENTS OR THAT THE
 OCCUPANCY CLASSIFICATION MAY NOT FALL UNDER THE FLORIDA
 FIRE PREVENTION CODE REQUIREMENTS.
  
 PLEASE PROVIDE A DESCRIPTION OF THE BUSINESS AND ENSURE
 COMPLIANCE WITH THE APPLICABLE FIRE CODES.
  
  
 2) A THOROUGH REVIEW CAN NOT BE COMPLETED DUE TO A LACK
 OF OCCUPANCY CLASSIFICATION.
  
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-17 Cont ID  
Sent By shill Date 2017-07-17 Time 14:10 Rev Time 0.00
Received By shill Date 2017-06-08 Time 09:05 Sent To  
Notes
2017-06-27 09:05:38PLANS IN C10 BIN.
 ***PERMIT #16110717 RIDING ALONG WITH THIS PERMIT
 #17061108. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-06-27 Cont ID  
Sent By jgomez Date 2017-06-27 Time 11:45 Rev Time 0.00
Received By jgomez Date 2017-06-27 Time 11:45 Sent To  
Notes
2017-06-27 11:45:231- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-06-27 Cont ID  
Sent By jgomez Date 2017-06-27 Time 12:18 Rev Time 0.00
Received By jgomez Date 2017-06-27 Time 12:18 Sent To  
Notes
2017-06-27 12:28:09RESIDENTIAL (?) ALTERATION, MECHANICAL REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- PROVIDE COMPLETE HEATING AND COOLING EQUIPMENT
 SIZING CALCULATIONS AND SUBMIT THE EQUIPMENT
 MANUFACTURER AND MODEL NUMBER AS REQUIRED BY SEC.
 R403.6.1 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
 NOTE: COORDINATE EQUIPMENT WITH ENERGY CALCULATIONS.
  
 2- PROVIDE A/C PLAN LISTING THE EQUIPMENT SPECIFIED ON
 ITEM #1 ABOVE. SEC. 107.3.5.3(10) CITY AMENDMENTS.
 NOTE: COORDINATE EQUIPMENT WITH ENERGY CALCULATIONS.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS..
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-06-28 Cont ID  
Sent By gjohnson Date 2017-06-28 Time 09:45 Rev Time 0.00
Received By gjohnson Date 2017-06-28 Time 09:45 Sent To  
Notes
2017-06-28 09:47:281ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. A SEPARATE PERMIT IS REQUIRED FOR THE DETACHED
 GARAGE BEING CONVERTED TO OFFICE.
  
 2. PLEASE SHOW COMPLIANCE WITH FBC ACC FOR THE
 FOLLOWING IN BOTH ACCESSIBLE BATHROOMS.
 (A) 603.2.3 DOOR SWING.
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
  
 EXCEPTIONS:
  
 1. DOORS TO A TOILET ROOM OR BATHING ROOM FOR A SINGLE
 OCCUPANT ACCESSED ONLY THROUGH A PRIVATE OFFICE AND NOT
 FOR COMMON USE OR PUBLIC USE SHALL BE PERMITTED TO
 SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE PROVIDED
 THE SWING OF THE DOOR CAN BE REVERSED TO COMPLY WITH
 603.2.3.
  
 2. WHERE THE TOILET ROOM OR BATHING ROOM IS FOR
 INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING WITH
 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE
 DOOR SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE
 CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY
 FIXTURE.
  
 (B) 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES
 OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE
 OF THE REFLECTING SURFACE 35 INCHES (890 MM) MAXIMUM
 ABOVE THE FINISH FLOOR OR GROUND.
  
 (C) 604.2 LOCATION.
 THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM
 TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR
 PARTITION, EXCEPT THAT THE WATER CLOSET SHALL BE 17
 INCHES (430 MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM
 FROM THE SIDE WALL OR PARTITION IN THE AMBULATORY
 ACCESSIBLE TOILET COMPARTMENT SPECIFIED IN 604.8.2.
 WATER CLOSETS SHALL BE ARRANGED FOR A LEFT-HAND OR
 RIGHT-HAND APPROACH.
  
 (D) 604.3.1 SIZE.
 CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED
 PERPENDICULAR FROM THE REAR WALL.
  
 (E) 604.4 SEATS.
 THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH
 FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES
 (485 MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS
 SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION.
  
 (F) 604.5.1 SIDE WALL.
 THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM)
 LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM
 THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM
 FROM THE REAR WALL.
 604.5.2 REAR WALL.
 THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24
 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.
  
 (G) 604.7 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE
 DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48
 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND
 SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL
 NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES
 NOT ALLOW CONTINUOUS PAPER FLOW.
  
  
 (E) LAVATORY 606.2 CLEAR FLOOR SPACE.
 A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR
 A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 (F) SHOWER 608.2.1 TRANSFER TYPE SHOWER COMPARTMENTS.
 TRANSFER TYPE SHOWER COMPARTMENTS SHALL BE 36 INCHES
 (915 MM) BY 36 INCHES (915 MM) CLEAR INSIDE DIMENSIONS
 MEASURED AT THE CENTER POINTS OF OPPOSING SIDES AND
 SHALL HAVE A 36 INCH (915 MM) WIDE MINIMUM ENTRY ON THE
 FACE OF THE SHOWER COMPARTMENT. CLEARANCE OF 36 INCHES
 (915 MM) WIDE MINIMUM BY 48 INCHES (1220 MM) LONG
 MINIMUM MEASURED FROM THE CONTROL WALL SHALL BE
 PROVIDED.
 608.3.1 TRANSFER TYPE SHOWER COMPARTMENTS.
 IN TRANSFER TYPE COMPARTMENTS, GRAB BARS SHALL BE
 PROVIDED ACROSS THE CONTROL WALL AND BACK WALL TO A
 POINT 18 INCHES (455 MM) FROM THE CONTROL WALL.
 608.4 SEATS.
 A FOLDING OR NON-FOLDING SEAT SHALL BE PROVIDED IN
 TRANSFER TYPE SHOWER COMPARTMENTS. A FOLDING SEAT SHALL
 BE PROVIDED IN ROLL-IN TYPE SHOWERS REQUIRED IN
 TRANSIENT LODGING GUEST ROOMS WITH MOBILITY FEATURES
 COMPLYING WITH 806.2. SEATS SHALL COMPLY WITH 610.
 608.5.1 TRANSFER TYPE SHOWER COMPARTMENTS.
 IN TRANSFER TYPE SHOWER COMPARTMENTS, THE CONTROLS,
 FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON
 THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (965 MM)
 MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE
 SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL
 15 INCHES (380 MM) MAXIMUM FROM THE CENTERLINE OF THE
 SEAT TOWARD THE SHOWER OPENING.
  
 (G) SHOW GRAB BARS MEASURE TO GRIPPING SURFACE. 609.4
 POSITION OF GRAB BARS.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE
  
 3. SHT. 4 OF4 FROM GARAGE CONVERSION. THE WASHING
 MACHINE DRAIN SHALL NOT CONNECT TO WET VENT OF BATHROOM
 GROUP IT SHALL BE SEPARATELY VENTED CONNECTED TO
 BUILDING DRAIN DOWN STREAM OF BATHROOM GROUP. PER FBC
 PL P3108.2.1
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2017-07-17 Cont ID  
Sent By kmartin Date 2017-07-17 Time 14:09 Rev Time 0.00
Received By shill Date 2017-07-17 Time 14:09 Sent To  
Notes
2017-07-17 14:10:27SEE ZONING REVIEW UNDER PERMIT 16110717
  