Plan Review Details - Permit 17060969
Plan Review Stops For Permit 17060969
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-09-05 Cont ID  
Sent By   Date 2017-09-05 Time 07:29 Rev Time 0.00
Received By jwitmer Date 2017-09-05 Time 07:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-08-07 Cont ID  
Sent By jwitmer Date 2017-08-07 Time 08:08 Rev Time 0.00
Received By jwitmer Date 2017-08-07 Time 07:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-06-26 Cont ID  
Sent By jwitmer Date 2017-06-26 Time 14:47 Rev Time 0.00
Received By jwitmer Date 2017-06-26 Time 11:54 Sent To  
Notes
2017-06-26 14:47:052014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17060969
 ADD: 5505 S. DIXIE HWY.
 CONT: FAYE E. CARTER CONSTRUCTION
 TEL: 561-747-3136
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JUNE 26/ 2017
 ACTION: DENIED
  
 1) SHEET 2 THE LIFE SAFETY SHEET:
  
 1A) THE PLANS INDICATE THE EXISTING COMMUNITY CORRIDOR
 IS TO BE ONE HOUR RATED (FBC-B TABLE 1018.1), PLEASE
 PROVIDE COMPLIANCE WITH 2014 FBC-B 703.7 MARKING AND
 IDENTIFICATION.
 FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE
 BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL
 REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS
 SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH
 SIGNS OR STENCILING. SUCH IDENTIFICATION SHALL:
 1. BE LOCATED IN ACCESSIBLE CONCEALED FLOOR,
 FLOOR-CEILING OR ATTIC SPACES;
 2. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL
 AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED
 HORIZONTALLY ALONG THE WALL OR PARTITION; AND
 3. INCLUDE LETTERING NOT LESS THAN 3 INCHES (76 MM ) IN
 HEIGHT WITH A MINIMUM 3/8 INCH (9.5 MM)
 STROKE IN A CONTRASTING COLOR INCORPORATING THE
 SUGGESTED WORDING. ?FIRE AND/OR SMOKE
 BARRIER?PROTECT ALL OPENINGS? OR OTHER WORDING.
  
 1B) PLEASE PROVIDE THE FIRE RATING OF THE EXISTING
 CORRIDOR DOORS, NOT GIVEN ON THE LIFE SAFETY PLAN?
 107.2.1.3./ FBC-B TABLE 716.5.
  
 2) THE MECHANICAL SHEET 1 PLEASE SEE AH UNIT # 5 IS
 ILLUSTRATED BEING INSTALLED IN THE FIRE RATED CORRIDOR
 WALL, PLEASE PROVIDE HOW THE FIRE RATING OF THIS 1 HOUR
 FIRE RATED CORRIDOR WALL WILL BE MAINTAINED.
 FBC-B 1018.6 CORRIDOR CONTINUITY. FIRE-RESISTANCE-RATED
 CORRIDORS SHALL BE CONTINUOUS FROM THE POINT OF ENTRY
 TO AN EXIT, AND SHALL NOT BE INTERRUPTED BY INTERVENING
 ROOMS. WHERE THE PATH OF EGRESS TRAVEL WITHIN A
 FIRE-RESISTANCE-RATED CORRIDOR TO THE EXIT INCLUDES
 TRAVEL ALONG UNENCLOSED EXIT ACCESS STAIRWAYS OR RAMPS,
 THE FIRE RESISTANCE-RATING SHALL BE CONTINUOUS FOR THE
 LENGTH OF THE STAIRWAY OR RAMP AND FOR THE LENGTH OF
 THE CONNECTING CORRIDOR ON THE ADJACENT FLOOR LEADING
 TO THE EXIT.
  
 3) SHEET 2 THE LIFE SAFETY PLAN ILLUSTRATES A
 CONFERENCE ROOM BUT DOES NOT STATE THE OCCUPANT LOAD OF
 THIS ROOM NOR IS THERE A FURNITURE LAYOUT INDICATING
 HOW MANY OCCUPANTS ARE TO BE IN THIS ROOM. THE ISSUE IS
 THERE ARE 4 SLIDING DOORS IN THIS ROOM(FBC-B 1008.1.2
 DOOR SWING) EGRESS DOORS ARE TO BE PIVOT OR SIDE
 SWINGING THE EXCEPTION 1 CAN BE USED FOR OFFICE AREAS
 WITH AN OCCUPANT LOAD OF 10 OR LESS. PLEASE PROVIDE THE
 OCCUPANT LOAD FOR THIS ROOM?
  
 4) SHEET 2 THE LIFE SAFETY PLAN SHOWS A NEW KITCHEN,
 NOT A BREAK ROOM BUT KITCHEN. PLEASE PROVIDE ELEVATIONS
 OF THE CABINETRY WHERE THE SINK IS LOCATED. PLEASE
 PROVIDE COMPLIANCE WITH SECTION 606.3 OF THE ACCESS.
 CODE. 606.3 HEIGHT.
 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT
 OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 5) SHEET 2 THE LIFE SAFETY PLAN SHOWS A SINGLE DRINKING
 FOUNTAIN PLEASE PROVIDE COMPLIANCE WITH 2014 ACCESS.
 CODE 211.2 MINIMUM NUMBER. NO FEWER THAN TWO DRINKING
 FOUNTAINS SHALL BE PROVIDED. ONE DRINKING FOUNTAIN
 SHALL COMPLY WITH 602.1 THROUGH 602.6 AND ONE DRINKING
 FOUNTAIN SHALL COMPLY WITH 602.7.
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY. WHEN THE COST OF ALTERATIONS
 NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED
 AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST
 OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE
 MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE
 ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COSTS. IN
 CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY
 SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE
 GREATEST ACCESS, IN THE FOLLOWING ORDER: (I) AN
 ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM
 FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV)
 ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING
 FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
 6) SHEET 1 SHOWS A NEW 3-0X6-8 EXTERIOR DOOR. THE PLANS
 DO NOT INDICATE IF THERE IS AN EXTERIOR WALL THAT IS
 BEING REMOVED TO CREATE THE NEW DOOR OPENING? 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED.
  
 7) PLEASE PROVIDE PRODUCT APPROVAL FOR THE NEW EXTERIOR
 DOOR. 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS.
  
 8) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-08-07 Cont ID  
Sent By jpearson Date 2017-08-07 Time 12:06 Rev Time 0.00
Received By jpearson Date 2017-08-07 Time 12:06 Sent To  
Notes
2017-08-07 12:06:00REVIEWED PER COMMENTS ONLY AND APPROVED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-07-03 Cont ID  
Sent By jleahy Date 2017-07-03 Time 16:28 Rev Time 0.00
Received By jleahy Date 2017-07-03 Time 16:28 Sent To  
Notes
2017-07-03 16:31:18FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 C405.2.2.2 OCCUPANCY SENSORS.
 OCCUPANCY SENSORS SHALL BE INSTALLED IN ALL CLASSROOMS,
 CONFERENCE/MEETING ROOMS, EMPLOYEE LUNCH AND
 BREAK ROOMS, PRIVATE OFFICES, RESTROOMS, STORAGE ROOMS
 AND JANITORIAL CLOSETS, AND OTHER SPACES 300 SQUARE
 FEET (28 M2) OR LESS ENCLOSED BY FLOOR-TO-CEILING
 HEIGHT PARTITIONS. THESE AUTOMATIC CONTROL DEVICES
 SHALL BE
 INSTALLED TO AUTOMATICALLY TURN OFF LIGHTS WITHIN 30
 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE, AND SHALL
 EITHER
 BE MANUAL ON OR SHALL BE CONTROLLED TO AUTOMATICALLY
 TURN THE LIGHTING ON TO NOT MORE THAN 50 PERCENT POWER.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2017-08-30 Cont ID  
Sent By pleduc Date 2017-08-30 Time   Rev Time 0.00
Received By pleduc Date 2017-08-29 Time 17:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-08-15 Cont ID  
Sent By pleduc Date 2017-08-15 Time   Rev Time 0.00
Received By pleduc Date 2017-08-15 Time 11:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-06-26 Cont ID  
Sent By pleduc Date 2017-06-26 Time   Rev Time 0.00
Received By pleduc Date 2017-06-23 Time 14:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2017-09-27 Time   Rev Time 0.00
Received By lmarchan Date 2017-09-25 Time 15:13 Sent To  
Notes
2017-09-26 15:13:43RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2017-09-07 Time   Rev Time 0.00
Received By lmarchan Date 2017-08-23 Time 09:20 Sent To  
Notes
2017-08-25 09:30:43B26

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-08-18 Cont ID  
Sent By gjohnson Date 2017-08-18 Time 14:29 Rev Time 0.00
Received By gjohnson Date 2017-08-01 Time 15:02 Sent To  
Notes
2017-08-02 15:02:20B26

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-05 Cont ID  
Sent By gjohnson Date 2017-07-05 Time 16:39 Rev Time 0.00
Received By gjohnson Date 2017-06-21 Time 13:42 Sent To  
Notes
2017-06-22 13:42:38B28

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2017-06-26 Cont ID  
Sent By jwitmer Date 2017-06-26 Time 12:21 Rev Time 0.00
Received By jwitmer Date 2017-06-26 Time 11:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2017-09-27 Cont ID  
Sent By ccole Date 2017-09-27 Time 13:37 Rev Time 0.00
Received By ccole Date 2017-09-27 Time 12:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2017-09-07 Cont ID  
Sent By ccole Date 2017-09-07 Time 10:51 Rev Time 0.00
Received By ccole Date 2017-09-07 Time 10:51 Sent To  
Notes
2017-09-07 10:53:343RD REVIEW FBC-2014 MECHANICAL
 PERMIT #17060969
 9/7/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) COMMENTS #2, 3, & 4 FROM THE PREVIOUS REVIEW STILL
 EXIST. I HAVE REPRINTED THE COMMENTS BELOW- PLEASE
 COMPLY,
  
 2) SHEET M1: IT APPEARS THAT AIR FROM AHU'S1 & 2 IS
 BEING TRANSFERRED FORM THE OFFICES BACK INTO THE
 CORRIDOR WHICH IS PROHIBITED PER SECTION 601.2. PLEASE
 NOTE THAT THE TRANSFER DUCT SIZES ARE NOT INDICATED.
  
 3) SHEET M1, AHU-1: A) THE PLAN INDICATES 1550 CFMS OF
 SUPPLY AIR FROM A 3-TON SYSTEM WHICH APPEARS TO EXCEED
 A TYPICAL 3-TON UNIT'S CAPACITY. B) THE 14 " MAIN TRUNK
 IS UNDERSIZED FOR 1450 CFMS AT TYPICAL 0.1: W.C.
 FRICTION LOSS.
  
 4) M1, AHU-5: A) THE PLAN INDICATES 2300 CFMS OF SUPPLY
 AIR FROM A 2-1/2-TON SYSTEM WHICH EXCEEDS THE CAPACITY
 OF THE SYSTEM. B) THE 14" AND 12" DUCTS ARE UNDERSIZED
 FOR 2300 AND 1200 CFMS AT A TYPICAL 0.1" W.C FRICTION
 LOSS.
  
 5) NEW COMMENT: THE NEW AC PLAN REQUIRES THE SIGNATURE
 OF THE PERSON WHO PREPARED IT- SECTION 107.2.1 WPB
 AMENDMENTS TO THE FBC- . ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-08-14 Cont ID  
Sent By ccole Date 2017-08-14 Time 15:23 Rev Time 0.00
Received By ccole Date 2017-08-14 Time 15:23 Sent To  
Notes
2017-08-14 15:56:442ND REVIEW FBC-2014 MECHANICAL
 PERMIT #17060969
 8/14/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE ENGINEER WHO SIGNED AND SEALED THE RESUBMITTED
 AC PLAN MUST PROVIDE A TITLE BLOCK ON THE PLAN- SECTION
 61G15-23.002 FAC.
  
 2) SHEET M1: IT APPEARS THAT AIR FROM AHU'S1 & 2 IS
 BEING TRANSFERRED FORM THE OFFICES BACK INTO THE
 CORRIDOR WHICH ISNPROHIBITED PER SECTION 601.2. PLEASE
 NOTE THAT THE TRANSFER DUCT SIZES ARE NOT INDICATED.
  
 3) SHEET M1, AHU-1: A) THE PLAN INDICATES 1550 CFMS OF
 SUPPLY AIR FROM A 3-TON SYSTEM WHICH APPEARS TO EXCEED
 A TYPICAL 3-TON UNIT'S CAPACITY. B) THE 14 " MAIN TRUNK
 IS UNDERSIZED FOR 1450 CFMS AT TYPICAL 0.1: W.C.
 FRICTION LOSS.
  
 4) M1, AHU-5: A) THE PLAN INDICATES 2300 CFMS OF SUPPLY
 AIR FROM A 2-1/2-TON SYSTEM WHICH EXCEEDS THE CAPACITY
 OF THE SYSTEM. B) THE 14" AND 12" DUCTS ARE UNDERSIZED
 FOR 2300 AND 1200 CFMS AT A TYPICAL 0.1" W.C FRICTION
 LOSS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-06-30 Cont ID  
Sent By ccole Date 2017-06-30 Time 09:48 Rev Time 0.00
Received By ccole Date 2017-06-30 Time 09:48 Sent To  
Notes
2017-06-30 10:05:441ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES
 PERMIT #17060969
 6/30/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE MECHANICAL PLANS ARE DEFICIENT. IN ORDER TO
 EXPEDITE THE SECOND REVIEW, PLEASE PROVIDE THE
 FOLLOWING:
  
 A) A SCOPE OF WORK OUTLINE- SECTION 107.2.1 WPB
 AMENDMENTS TO THE FBC
 B) MINIMUM VENTILATION CALCULATIONS FOR ALL ROOMS AND
 SPACES AFFECTED BY THE ALTERATIONS- SECTIONS 809.1 &
 809.2 FBC-14 EXISTING BUILDING.
 C) AC COOLING AND HEATING CALCULATIONS. IF SYSTEMS ARE
 REPLACEMENTS CALCULATIONS ARE NOT REQUIRED, HOWEVER AC
 CHANGEOUT FORMS AND AHRI CERTIFICATES MUST BE
 SUBMITTED- SECTION C403.2.1 ENERGY CONSERVATION.
 D) AC EQUIPMENT SCHEDULES- 107.2.1
 E) AC EQUIPMENT LOCATIONS AND INSTALLATION DETAILS.
 PLEASE NOTE THAT WIND LOAD ENGINEERING IS REQUIRED FOR
 EXTERIOR CONDENSER INSTALLATIONS- SECTION 301.15 FBC-15
 MECHANICAL.
 F) AIR DEVICE SCHEDULE- 107.2.1, SECTION 603 FBC-14
 MECHANICAL.
 G) RETURN AIR PLENUM DETAILS- SECTION 602.
 H) DUCT SUPPPORT AND CONNECTIO N DETAILS PER SMACNA
 STANDARDS
 I) ACCESS FOR SERVICE AND REPLACEMENT OF THE ABOVE
 CEILING AIR HANDLERS- SECTION 306.1.
 J) CONDENSATE DISPOSAL PLANS FOR THE AIR HANDLERS-
 SECTION 307.
  
 2) PLEASE NOTE THAT FURTHER COMMENTS MAY OCCUR AT
 SECOND REVIEW. WHEN RESUBMITTING, IT IS HELPFUL TO
 PROVIDE A RESPONSE LETTER ADDRESSING EACH ITEM ALONG
 WITH THE CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE
 INSERT CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-08-18 Cont ID  
Sent By gjohnson Date 2017-08-18 Time 14:29 Rev Time 0.00
Received By gjohnson Date 2017-08-18 Time 14:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-07-05 Cont ID  
Sent By gjohnson Date 2017-07-05 Time 16:34 Rev Time 0.00
Received By gjohnson Date 2017-07-05 Time 14:20 Sent To  
Notes
2017-07-05 16:39:381ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. PROVIDE WATER RISER DIAGRAM. PER WPB AMEND TO FBC
 107.3.5.1.3(13)
  
 2.THE KITCHEN SINK SHALL COMPLY WITH FBC ACC 606.2
 CLEAR FLOOR SPACE.
 A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR
 A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED
 606.3 HEIGHT.
 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT
 OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES
 (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  