| Plan Review Stops For Permit 17060956 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-08-09 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-08-09 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-27 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-27 |
Time |
06:44 |
Sent To |
|
|
| Notes |
| 2017-06-27 07:16:16 | BUILDING PROVISO: | | | | | | DOOR HARDWARE 2014 ACCESS. CODE 404.2.7. | | | HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE | | | PARTS ON DOORS AND GATES SHALL COMPLY WITH 309.4. | | | 309.4 OPERATION. OPERABLE PARTS SHALL BE OPERABLE | | | WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, | | | PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED | | | TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS | | | MAXIMUM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-08-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-03 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-03 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-07-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-07-12 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-07-12 |
Time |
16:21 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-07-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-07-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-07-31 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-06-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-06-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-06-23 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2017-06-23 14:06:16 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE IS NO REFERENCE OF COMPLIANCE WITH THE FLORIDA | | | FIRE PREVENTION CODE. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2009 EDITION. | | | | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2010 EDITION. | | | | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | | | | | | | | PLEASE ENSURE COMPLIANCE AND PROVIDE AN APPLICABLE | | | NOTE. | | | | | | | | | | | | 2) SHEET A 1 - UNDER THE GENERAL NOTES SECTION THERE IS | | | A CODE REFERNCE TO 101, 22.2.2.3. THIS REFERENCE IS NOT | | | APPLICABLE TO THIS OCCUPANCY AND DOES NOT APPEAR | | | RELEVANT TO THE PROJECT. | | | | | | PLEASE REVIEW, CLRIFY AND/OR CORRECT. | | | | | | | | | | | | 3) THERE IS NO INDICATION OF ANY DOOR HARDWARE HANDLE | | | OR LATCHING. | | | | | | PLEASE PROVIDE AND ENSURE IT COMPLIES WITH NFPA 101, | | | CHAPTER 13, AND CHAPTER 7. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-08-17 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2017-08-18 10:24:11 | RESUB ROUTED TO AJONES VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-07-27 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-07-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-06-21 |
Time |
15:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-27 |
Time |
06:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-27 |
Time |
06:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-08-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-21 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-21 |
Time |
18:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-08-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-15 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-15 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2017-08-15 13:50:21 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17060956 | | | 8/14/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE SUBMITTED FORM C402-2014 MAY BE USED FOR | | | ALTERATIONS, RENOVATIONS, AND BUILDING SYSTEMS BUT NOT | | | OR ADDITIONS- SEE SECTION C101.5.1 & C101.5.1.1 FBC-14 | | | ENERGY CONSERVATION. SUBMIT ENERGY CALCULATIONS, AND AC | | | COOLING AND HEATING CALCULATIONS FOR THE NEW STORAGE | | | ADDITION- SEE SECTIONS C101.4.3, C101.5.1, & C403.2.1 | | | FBC-14 ENERGY CONSERVATION. | | | | | | 2) PLEASE NOTE THAT ALL PLANS AND DOCUMENTS SHALL BE | | | SUBMITTED IN DUPLICATE (TWO COPIES)- SECTION 107.2.1 | | | WPB AMENDMENTS TO THE FBC. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-13 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-13 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2017-07-13 09:42:47 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17060956 | | | 7/13/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SUBMIT ENERGY CALCULATIONS, AND AC COOLING AND | | | HEATING CALCULATIONS FOR THE NEW STORAGE ADDITION- SEE | | | SECTIONS C101.4.3, C101.5.1, & C403.2.1 FBC-14 ENERGY | | | CONSERVATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-08-21 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-08-21 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-08-21 |
Time |
10:52 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-08-10 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2017-08-10 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2017-08-10 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2017-06-30 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2017-06-30 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|