Plan Review Details - Permit 17060953
Plan Review Stops For Permit 17060953
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-07-14 Cont ID  
Sent By skennedy Date 2017-07-14 Time 08:45 Rev Time 0.00
Received By skennedy Date 2017-07-14 Time 08:45 Sent To  
Notes
2017-07-14 08:52:02APPROVED WITH REQUIREMENT FOR REVISED FLOOR PLAN TO
 SHOW BUILDING & ELECTRIC.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-07-05 Cont ID  
Sent By cthroop Date 2017-07-05 Time 16:36 Rev Time 0.00
Received By cthroop Date 2017-07-05 Time 09:30 Sent To  
Notes
2017-07-05 16:38:27BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE DETAIL FOR CONCRETE REPAIR.
 2. DESIGNER TO PRINT NAME AND SIGN PLAN.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2017-07-14 Cont ID  
Sent By skennedy Date 2017-07-14 Time 08:52 Rev Time 0.00
Received By skennedy Date 2017-07-14 Time 08:52 Sent To  
Notes
2017-07-14 08:52:46A REVISION IS REQUIRED FOR ELECTRICAL PRIOR TO ISSUANCE
 OF AN ELECTRICAL PERMIT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-07-05 Cont ID  
Sent By jleahy Date 2017-07-05 Time 08:43 Rev Time 0.00
Received By jleahy Date 2017-07-05 Time 08:43 Sent To  
Notes
2017-07-05 08:44:57FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NEED TO SHOW WHAT IS BEING DONE WHAT IS BEING MOVED.
  
 FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
 THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM
 SIZE, SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED
 TO RECORDS MANAGEMENT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-07-14 Cont ID  
Sent By gjohnson Date 2017-07-14 Time 08:56 Rev Time 0.00
Received By gjohnson Date 2017-07-10 Time 14:21 Sent To  
Notes
2017-07-10 14:21:53R36

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-05 Cont ID  
Sent By cthroop Date 2017-07-05 Time 16:36 Rev Time 0.00
Received By cthroop Date 2017-06-21 Time 16:03 Sent To  
Notes
2017-06-22 16:03:58R36

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-07-14 Cont ID  
Sent By gjohnson Date 2017-07-14 Time 08:53 Rev Time 0.00
Received By gjohnson Date 2017-07-13 Time 16:48 Sent To  
Notes
2017-07-14 08:56:03PROVISO
  
 1. PROVIDE FLOOR PLAN SHOWING LOCATION OR FIXTURES.

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-06-30 Cont ID  
Sent By gjohnson Date 2017-06-30 Time 15:09 Rev Time 0.00
Received By gjohnson Date 2017-06-30 Time 15:09 Sent To  
Notes
2017-06-30 15:22:041ST REVIEW: FBC 2014 5TH EDITION
  
  
 PLUMBING COMMENTS:
  
 1. PROVIDE FLOOR PLAN SHOWING LOCATION OF FIXTURES. PER
 WPB AMEND TO FBC 107.2.1
  
 2. WHAT PLUMBING WORK IS BEING DONE IN BATHROOM 1. PER
 WPB AMEND TO FBC 107.2.1
  
 3. PROVIDE PLUMBING RISER DIAGRAM FOR NEW PIPING. PER
 WPB AMEND TO FBC 107.3.5.3
  
 4. PLANS SHALL BE SIGNED BY PERSON RESPONSIBLE FOR
 DESIGN. PER WPB AMEND TO FBC 107.2.1
  
 5. PROVIDE DETAIL OF SLAB REPAIR. PER WPB AMEND TO FBC
 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  