Plan Review Details - Permit 17060953
| Plan Review Stops For Permit 17060953 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-07-14 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-07-14 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2017-07-14 08:52:02 | APPROVED WITH REQUIREMENT FOR REVISED FLOOR PLAN TO | | | SHOW BUILDING & ELECTRIC. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-05 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-05 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2017-07-05 16:38:27 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE DETAIL FOR CONCRETE REPAIR. | | | 2. DESIGNER TO PRINT NAME AND SIGN PLAN. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-07-14 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-07-14 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2017-07-14 08:52:46 | A REVISION IS REQUIRED FOR ELECTRICAL PRIOR TO ISSUANCE | | | OF AN ELECTRICAL PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-07-05 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-07-05 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2017-07-05 08:44:57 | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | | NFPA 70 2011 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NEED TO SHOW WHAT IS BEING DONE WHAT IS BEING MOVED. | | | | | | FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM | | | SIZE, SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED | | | TO RECORDS MANAGEMENT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-14 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-10 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-05 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-21 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-14 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-13 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2017-07-14 08:56:03 | PROVISO | | | | | | 1. PROVIDE FLOOR PLAN SHOWING LOCATION OR FIXTURES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-30 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-30 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2017-06-30 15:22:04 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE FLOOR PLAN SHOWING LOCATION OF FIXTURES. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 2. WHAT PLUMBING WORK IS BEING DONE IN BATHROOM 1. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 3. PROVIDE PLUMBING RISER DIAGRAM FOR NEW PIPING. PER | | | WPB AMEND TO FBC 107.3.5.3 | | | | | | 4. PLANS SHALL BE SIGNED BY PERSON RESPONSIBLE FOR | | | DESIGN. PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. PROVIDE DETAIL OF SLAB REPAIR. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|