Plan Review Details - Permit 17060870
Plan Review Stops For Permit 17060870
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-07-31 Cont ID  
Sent By jwitmer Date 2017-07-31 Time 08:34 Rev Time 0.00
Received By jwitmer Date 2017-07-31 Time 07:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-06-24 Cont ID  
Sent By jwitmer Date 2017-06-24 Time 09:32 Rev Time  
Received By jwitmer Date 2017-06-24 Time 08:16 Sent To  
Notes
2017-06-24 09:32:552014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17060870
 ADD: 1505 BELVEDERE RD.
 CONT: TBD/ TO BE DETERMINED
 TEL: 561-248-8809
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. JUNE 24, 2017
 ACTION: DENIED
  
 1) SHEET A -2:
 1A) SHEET A-2 SHOWS THE PORTICO AND FRONT ENTRY DRIVE
 BEING BROUGHT UP TO THE SAME GRADE (ELEVATION) AS THE
 SIDEWALK. PLEASE PROVIDE HOW COMPLIANCE WITH THE 2014
 FBC-ACCESS. CODE SECTION 209.2.1 PASSENGER LOADING
 ZONES. PASSENGER LOADING ZONES, EXCEPT THOSE REQUIRED
 TO COMPLY WITH 209.2.2 SHALL PROVIDE AT LEAST ONE
 PASSENGER LOADING ZONE COMPLYING WITH ACCESS. CODE 503.
  
 1A)(1) 503.2 VEHICLE PULL-UP SPACE. PASSENGER LOADING
 ZONES SHALL PROVIDE A VEHICULAR PULL-UP SPACE 96 INCHES
 (2440 MM) WIDE MINIMUM AND 20 FEET (6100 MM) LONG
 MINIMUM.
  
 1A)(2) 503.3 ACCESS AISLE. PASSENGER LOADING ZONES
 SHALL PROVIDE ACCESS AISLES COMPLYING WITH 503 ADJACENT
 TO THE VEHICLE PULL-UP SPACE. ACCESS AISLES SHALL
 ADJOIN AN ACCESSIBLE ROUTE AND SHALL NOT OVERLAP THE
 VEHICULAR WAY.
  
 2) SHEET A2 THE FLOOR PLAN INDICATES A NEW USAGE FROM
 AN OFFICE TO A NEWLY PROPOSED EMPLOYEE BREAK ROOM.
 PLEASE NOTE THERE ARE STAIRS TO THIS BREAK ROOM BUT NO
 VERTICAL ACCESSIBILITY TO THE BREAK ROOM.
 SEE ACCESS. CODE 201.1.1 VERTICAL ACCESSIBILITY.
 BUILDINGS, STRUCTURES AND FACILITIES MUST, AT A
 MINIMUM, COMPLY WITH THE REQUIREMENTS OF THE ADA
 STANDARDS FOR ACCESSIBLE DESIGN.
  
 3) SHEET A-9 SHOWS A NEW BUFFET AND SEATING AREA.
 PLEASE SHOW COMPLIANCE WITH:
 ACCESSIBILITY CODE/ DINING SURFACES.
  
 THE LIFE SAFETY SHEET DOES NOT SHOW COMPLIANCE WITH THE
 2014 FBC-ACCESSIBILITY CODE;
 3A) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE
 CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE
 SEATING SPACES AND STANDING SPACES AT THE DINING
 SURFACES SHALL COMPLY WITH 902.
  
 3B) 902.1 .DINING SURFACES AND WORK SURFACES SHALL
 COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 GENERAL.
 DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS,
 TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK
 SURFACES INCLUDE WRITING SURFACES, STUDY CARRELS,
 STUDENT LABORATORY STATIONS, BABY CHANGING AND OTHER
 TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON
 COUNTERS, AND WHERE COVERED BY THE ABA SCOPING
 PROVISIONS, EMPLOYEE WORK STATIONS.
  
 3B)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR
 SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 3B)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM AND
 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
  
 4) PLEASE PROVIDE THE FOLLOWING MINIMUM REQUIREMENTS
 FOR PLAN REVIEW. 2014 FLORIDA BUILDING CODE W 2014 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1, ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW
 CRITERIA FOR BUILDINGS
 107.3.5.1 COMMERCIAL BUILDINGS:
 107.3.5.1.1 BUILDING
 2. OCCUPANCY GROUP
 3. MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED
 (SEE TABLE 503).
 4. IS THE BUILDING FIRE SPRINKLERED OR NOT? IS IT
 REQUIRED?
 5. LIFE SAFETY PLAN
 6. OCCUPANT LOAD
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-08-02 Cont ID  
Sent By jpearson Date 2017-08-02 Time 09:24 Rev Time 0.00
Received By jpearson Date 2017-08-02 Time 09:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-06-27 Cont ID  
Sent By jleahy Date 2017-06-27 Time 08:39 Rev Time 0.00
Received By jleahy Date 2017-06-27 Time 08:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-07-28 Cont ID  
Sent By pleduc Date 2017-07-28 Time   Rev Time 0.00
Received By pleduc Date 2017-07-28 Time 10:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-06-23 Cont ID  
Sent By pleduc Date 2017-06-23 Time   Rev Time 0.00
Received By pleduc Date 2017-06-23 Time 12:04 Sent To  
Notes
2017-06-23 13:37:12THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
  
 1) THERE IS NOLLIFE SAFETY PLAN SUBMITTED WITH THIS
 PLAN SET.
  
 COMPLETE LIFE SAFETY PLANS FOR THIS OCCUPANCY SHALL BE
 PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS,
 EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A
 PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE
 SAFETY FEATURES AND EQUIPMENT.
  
 IF THE HOTEL IS TO REMAIN OPEN, PLEASE INCLUDE AND
 INDICATE, WITH DETAILS, HOW THE EXITS WILL BE
 MAINTAINED UNOBSTRUCTED DURING ALL PHASES OF
 CONSTRUCTION.
  
  
  
 2) SHEET A 2 - THE OPENING TO THE HALL WAS CREATED BY
 THE REMOVAL OF A DOOR. THERE IS NO WIDTH OR HEIGHT
 DIMENSION THAT SHOWS COMPLAINCE WITH NFPA 101, CHAPTER
 7, MEANS OF EGRESS.
  
 7.1.5* HEADROOM.
 7.1.5.1 MEANS OF EGRESS SHALL BE DESIGNED AND
 MAINTAINED TO PROVIDE HEADROOM IN ACCORDANCE WITH OTHER
 SECTIONS OF THIS CODE, AND SUCH HEADROOM SHALL BE NOT
 LESS THAN 7 FT 6 IN. (2285 MM), WITH PROJECTIONS FROM
 THE CEILING NOT LESS THAN 6 FT 8 IN. (2030 MM) WITH A
 TOLERANCE OF ?? IN. (?19 MM), ABOVE THE FINISHED FLOOR,
 UNLESS OTHERWISE SPECIFIED BY ANY OF THE FOLLOWING:
 (1) IN EXISTING BUILDINGS, THE CEILING HEIGHT SHALL BE
 NOT LESS THAN 7 FT (2135 MM) FROM THE FLOOR, WITH
 PROJECTIONS FROM THE CEILING NOT LESS THAN 6 FT 8 IN.
 (2030 MM) NOMINAL ABOVE THE FLOOR.
 (2) HEADROOM IN INDUSTRIAL EQUIPMENT ACCESS AREAS AS
 PROVIDED IN 40.2.5.2 SHALL BE PERMITTED.
  
 7.3.4 MINIMUM WIDTH.
 7.3.4.1 THE WIDTH OF ANY MEANS OF EGRESS, UNLESS
 OTHERWISE PROVIDED IN 7.3.4.1.1 THROUGH 7.3.4.1.3,
 SHALL BE AS FOLLOWS:
 (1) NOT LESS THAN THAT REQUIRED FOR A GIVEN EGRESS
 COMPONENT IN THIS CHAPTER OR CHAPTERS 11 THROUGH 43
 (2) NOT LESS THAN 36 IN. (915 MM) WHERE ANOTHER PART OF
 THIS CHAPTER AND CHAPTERS 11 THROUGH 43 DO NOT SPECIFY
 A MINIMUM WIDTH
  
 7.3.4.1.2 IN EXISTING BUILDINGS, THE WIDTH OF EXIT
 ACCESS SHALL BE PERMITTED TO BE NOT LESS THAN 28 IN.
 (710 MM).
  
 PLEASE PROVIDE/CORRECT INDICATIONS OF COMPLIANCE.
  
  
  
 3) SHEET A 9 - THERE IS A SEATING PLAN INDICATED. THERE
 IS NO OCCUPANY LOAD CALCULATION OR ANY INDICATED
 DIMENSIONS THAT SUPPORT THIS SEATING PLAN AND THE
 OCCUPANCY THAT GOES WITH IT.
  
 PLEASE PROVIDE A DETAILED OCCUPANCY LOAD CALCULATION TO
 SUPPORT THIS SEATING PLAN. THIS CAN BE ADDRESSED ALONG
 WITH # 1 ABOVE.
  
  
  
 4) THERE IS NO INDICATION OF ANY EXISTING FIRE
 SPRINKLER SYSTEM.
  
 PLEASE PROVIDE A NOTE OF COMPLIANCE. ADDITIONALLY, ALL
 WORK ON THE FIRE SPRINKLER SYSTEM SHALL BE DONE BY
 CERTIFIED CONTRACTORS UNDER SEPARATE SHOP DRAWING.
  
  
  
  
 5) THERE IS NO INDICATION OF ANY EXISTING FIRE ALARM
 SYSTEM.
  
 PLEASE PROVIDE A NOTE OF COMPLIANCE. ADDITIONALLY, ALL
 WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE BY
 CERTIFIED CONTRACTORS UNDER SEPARATE SHOP DRAWING.
  
  
  
 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-08-02 Cont ID  
Sent By jpearson Date 2017-08-02 Time 09:24 Rev Time 0.00
Received By jpearson Date 2017-07-25 Time 15:25 Sent To  
Notes
2017-07-26 15:25:37B13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-06-27 Cont ID  
Sent By jleahy Date 2017-06-27 Time 08:39 Rev Time 0.00
Received By jleahy Date 2017-06-19 Time 15:42 Sent To  
Notes
2017-06-21 15:42:11B17